{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10199947"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10199947","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Electrochemical safety of neural implants: in vitro study of platinum electrodes behaviour near Shannon’s safe stimulation limit","abstract":"In neural electrical stimulation, safe stimulation guidelines are crucial for effective treatment while avoiding neural damage and electrode degradation. Shannon’s parameter k sets conditions on stimulation parameters to prevent neural damage, though the underlying mechanisms remain unclear. An experimental approach was designed to explore the electrochemical mechanisms involved in the charge injection behaviour of platinum electrodes near Shannon’s safe limit. A custom stimulator was developed to deliver biphasic, cathodic-first, charge-balanced, asymmetric, current-controlled pulse trains, while monitoring electrode potential. The pulse trains were calibrated to approach and exceed Shannon’s limit. A characterisation and conditioning sequence, including electrochemical impedance spectroscopy and cyclic voltammetry, was implemented to ensure repeatability. The influence of various experimental parameters was investigated, such as electrode design (recess, electrode size, electrode shape), stimulation protocol (pulse width), and electrolyte composition (pH, ionic strength, density, buffer system, dissolved gas). Initial results in saline confirmed previous findings: positive potential ratcheting from irreversible charge injection linked to molecular oxygen reduction, and correlation of Shannon’s limit with oxide-mediated platinum dissolution. This mechanism held consistent despite parameter variations, though the onset k-value differed. Changes in electrode design affected current density distribution and diffusion profile; variations in pulse width influenced polarisation due to longer diffusion times; electrolyte composition changes impacted ionic interactions, including double-layer capacitance, faradaic mechanisms, and diffusion. Double-layer capacitance and diffusion profile emerged as key factors determining oxidemediated platinum dissolution threshold and rate. Future research should further examine how the in vivo environment impacts these parameters and work towards developing a standardised characterisation method for stimulation electrodes.","abstract_html":"In neural electrical stimulation, safe stimulation guidelines are crucial for effective treatment while avoiding neural damage and electrode degradation. Shannon’s parameter k sets conditions on stimulation parameters to prevent neural damage, though the underlying mechanisms remain unclear. An experimental approach was designed to explore the electrochemical mechanisms involved in the charge injection behaviour of platinum electrodes near Shannon’s safe limit. A custom stimulator was developed to deliver biphasic, cathodic-first, charge-balanced, asymmetric, current-controlled pulse trains, while monitoring electrode potential. The pulse trains were calibrated to approach and exceed Shannon’s limit. A characterisation and conditioning sequence, including electrochemical impedance spectroscopy and cyclic voltammetry, was implemented to ensure repeatability. The influence of various experimental parameters was investigated, such as electrode design (recess, electrode size, electrode shape), stimulation protocol (pulse width), and electrolyte composition (pH, ionic strength, density, buffer system, dissolved gas). Initial results in saline confirmed previous findings: positive potential ratcheting from irreversible charge injection linked to molecular oxygen reduction, and correlation of Shannon’s limit with oxide-mediated platinum dissolution. This mechanism held consistent despite parameter variations, though the onset k-value differed. Changes in electrode design affected current density distribution and diffusion profile; variations in pulse width influenced polarisation due to longer diffusion times; electrolyte composition changes impacted ionic interactions, including double-layer capacitance, faradaic mechanisms, and diffusion. Double-layer capacitance and diffusion profile emerged as key factors determining oxidemediated platinum dissolution threshold and rate. Future research should further examine how the in vivo environment impacts these parameters and work towards developing a standardised characterisation method for stimulation electrodes.","abstract_has_math":false,"creators":["Niederhoffer, Thomas"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Lancashire, Henry","Vanhoestenberghe, Anne"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-11","date_published":"2024-11","updated_at":"2026-11-26T07:37:31Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10199947/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10199947/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10199947","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10199947","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lancashire, Henry","Vanhoestenberghe, Anne"]},{"key":"dc:creator","label":"Author","values":["Niederhoffer, Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-11-28"]},{"key":"dc:date.issued","label":"Date","values":["2024-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics & Biomedical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10199947/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In neural electrical stimulation, safe stimulation guidelines are crucial for effective treatment while avoiding neural damage and electrode degradation. Shannon’s parameter k sets conditions on stimulation parameters to prevent neural damage, though the underlying mechanisms remain unclear. An experimental approach was designed to explore the electrochemical mechanisms involved in the charge injection behaviour of platinum electrodes near Shannon’s safe limit. A custom stimulator was developed to deliver biphasic, cathodic-first, charge-balanced, asymmetric, current-controlled pulse trains, while monitoring electrode potential. The pulse trains were calibrated to approach and exceed Shannon’s limit. A characterisation and conditioning sequence, including electrochemical impedance spectroscopy and cyclic voltammetry, was implemented to ensure repeatability. The influence of various experimental parameters was investigated, such as electrode design (recess, electrode size, electrode shape), stimulation protocol (pulse width), and electrolyte composition (pH, ionic strength, density, buffer system, dissolved gas). Initial results in saline confirmed previous findings: positive potential ratcheting from irreversible charge injection linked to molecular oxygen reduction, and correlation of Shannon’s limit with oxide-mediated platinum dissolution. This mechanism held consistent despite parameter variations, though the onset k-value differed. Changes in electrode design affected current density distribution and diffusion profile; variations in pulse width influenced polarisation due to longer diffusion times; electrolyte composition changes impacted ionic interactions, including double-layer capacitance, faradaic mechanisms, and diffusion. Double-layer capacitance and diffusion profile emerged as key factors determining oxidemediated platinum dissolution threshold and rate. Future research should further examine how the in vivo environment impacts these parameters and work towards developing a standardised characterisation method for stimulation electrodes."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Electrochemical safety of neural implants: in vitro study of platinum electrodes behaviour near Shannon’s safe stimulation limit"]}]}],"canonical_facts":{"dc:contributor":["Lancashire, Henry","Vanhoestenberghe, Anne"],"dc:creator":["Niederhoffer, Thomas"],"dc:date":["2024-11-28"],"dc:date.issued":["2024-11"],"dc:description.abstract":["In neural electrical stimulation, safe stimulation guidelines are crucial for effective treatment while avoiding neural damage and electrode degradation. Shannon’s parameter k sets conditions on stimulation parameters to prevent neural damage, though the underlying mechanisms remain unclear. An experimental approach was designed to explore the electrochemical mechanisms involved in the charge injection behaviour of platinum electrodes near Shannon’s safe limit. A custom stimulator was developed to deliver biphasic, cathodic-first, charge-balanced, asymmetric, current-controlled pulse trains, while monitoring electrode potential. The pulse trains were calibrated to approach and exceed Shannon’s limit. A characterisation and conditioning sequence, including electrochemical impedance spectroscopy and cyclic voltammetry, was implemented to ensure repeatability. The influence of various experimental parameters was investigated, such as electrode design (recess, electrode size, electrode shape), stimulation protocol (pulse width), and electrolyte composition (pH, ionic strength, density, buffer system, dissolved gas). Initial results in saline confirmed previous findings: positive potential ratcheting from irreversible charge injection linked to molecular oxygen reduction, and correlation of Shannon’s limit with oxide-mediated platinum dissolution. This mechanism held consistent despite parameter variations, though the onset k-value differed. Changes in electrode design affected current density distribution and diffusion profile; variations in pulse width influenced polarisation due to longer diffusion times; electrolyte composition changes impacted ionic interactions, including double-layer capacitance, faradaic mechanisms, and diffusion. Double-layer capacitance and diffusion profile emerged as key factors determining oxidemediated platinum dissolution threshold and rate. Future research should further examine how the in vivo environment impacts these parameters and work towards developing a standardised characterisation method for stimulation electrodes."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10199947/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics & Biomedical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Electrochemical safety of neural implants: in vitro study of platinum electrodes behaviour near Shannon’s safe stimulation limit"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:37:31Z"}