{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10210436"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10210436","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"New automated segment classification, withdrawal time measurement, phase detection, and explainable diagnosis methods for colonoscopy using deep learning","abstract":"Colonoscopy is widely regarded as the gold standard for the early diagnosis of colorectal cancer. Numerous methods for detecting and diagnosing polyps have been developed, with many achieving important success. Computer-aided detection and diagnosis systems are increasingly being integrated into real-time procedures. Traditionally, the quality of a colonoscopy has been primarily assessed by the Adenoma Detection Rate (ADR), but other important metrics also contribute to evaluating a procedure’s quality. These include withdrawal time, the number of resections, cecal intubation, and retroflexion. However, these metrics are often manually recorded by the clinician, which can be time-consuming and sometimes overlooked. Utilizing these metrics as quality indicators offers several benefits, such as identifying clinicians who may need additional training, providing a consistent method for comparing procedure quality, and generating more data for future research. To realise these benefits, automatic and consistent measurement methods are essential. This thesis addresses this challenge by offering solutions for several key metrics: cecum detection, withdrawal time measurement, colonic segment classification, detection of cleaning and therapeutic phases, retroflexion detection, and classification of out-ofbody segments. Additionally, a novel approach to polyp diagnosis using medically explainable features, rather than a simple final diagnosis, is proposed to enhance clinician training and improve the explainability of computer-aided diagnosis systems. All these methods are designed to be automated and easily integrated into existing polyp detection systems and medical devices","abstract_html":"Colonoscopy is widely regarded as the gold standard for the early diagnosis of colorectal cancer. Numerous methods for detecting and diagnosing polyps have been developed, with many achieving important success. Computer-aided detection and diagnosis systems are increasingly being integrated into real-time procedures. Traditionally, the quality of a colonoscopy has been primarily assessed by the Adenoma Detection Rate (ADR), but other important metrics also contribute to evaluating a procedure’s quality. These include withdrawal time, the number of resections, cecal intubation, and retroflexion. However, these metrics are often manually recorded by the clinician, which can be time-consuming and sometimes overlooked. Utilizing these metrics as quality indicators offers several benefits, such as identifying clinicians who may need additional training, providing a consistent method for comparing procedure quality, and generating more data for future research. To realise these benefits, automatic and consistent measurement methods are essential. This thesis addresses this challenge by offering solutions for several key metrics: cecum detection, withdrawal time measurement, colonic segment classification, detection of cleaning and therapeutic phases, retroflexion detection, and classification of out-ofbody segments. Additionally, a novel approach to polyp diagnosis using medically explainable features, rather than a simple final diagnosis, is proposed to enhance clinician training and improve the explainability of computer-aided diagnosis systems. All these methods are designed to be automated and easily integrated into existing polyp detection systems and medical devices","abstract_has_math":false,"creators":["De Carvalho, Thomas"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-06","date_published":"2025-06","updated_at":"2026-11-26T07:40:17Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10210436/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10210436/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10210436","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10210436","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["De Carvalho, Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-06-28"]},{"key":"dc:date.issued","label":"Date","values":["2025-06"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics and Biomedical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10210436/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Colonoscopy is widely regarded as the gold standard for the early diagnosis of colorectal cancer. Numerous methods for detecting and diagnosing polyps have been developed, with many achieving important success. Computer-aided detection and diagnosis systems are increasingly being integrated into real-time procedures. Traditionally, the quality of a colonoscopy has been primarily assessed by the Adenoma Detection Rate (ADR), but other important metrics also contribute to evaluating a procedure’s quality. These include withdrawal time, the number of resections, cecal intubation, and retroflexion. However, these metrics are often manually recorded by the clinician, which can be time-consuming and sometimes overlooked. Utilizing these metrics as quality indicators offers several benefits, such as identifying clinicians who may need additional training, providing a consistent method for comparing procedure quality, and generating more data for future research. To realise these benefits, automatic and consistent measurement methods are essential. This thesis addresses this challenge by offering solutions for several key metrics: cecum detection, withdrawal time measurement, colonic segment classification, detection of cleaning and therapeutic phases, retroflexion detection, and classification of out-ofbody segments. Additionally, a novel approach to polyp diagnosis using medically explainable features, rather than a simple final diagnosis, is proposed to enhance clinician training and improve the explainability of computer-aided diagnosis systems. All these methods are designed to be automated and easily integrated into existing polyp detection systems and medical devices"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["New automated segment classification, withdrawal time measurement, phase detection, and explainable diagnosis methods for colonoscopy using deep learning"]}]}],"canonical_facts":{"dc:creator":["De Carvalho, Thomas"],"dc:date":["2025-06-28"],"dc:date.issued":["2025-06"],"dc:description.abstract":["Colonoscopy is widely regarded as the gold standard for the early diagnosis of colorectal cancer. Numerous methods for detecting and diagnosing polyps have been developed, with many achieving important success. Computer-aided detection and diagnosis systems are increasingly being integrated into real-time procedures. Traditionally, the quality of a colonoscopy has been primarily assessed by the Adenoma Detection Rate (ADR), but other important metrics also contribute to evaluating a procedure’s quality. These include withdrawal time, the number of resections, cecal intubation, and retroflexion. However, these metrics are often manually recorded by the clinician, which can be time-consuming and sometimes overlooked. Utilizing these metrics as quality indicators offers several benefits, such as identifying clinicians who may need additional training, providing a consistent method for comparing procedure quality, and generating more data for future research. To realise these benefits, automatic and consistent measurement methods are essential. This thesis addresses this challenge by offering solutions for several key metrics: cecum detection, withdrawal time measurement, colonic segment classification, detection of cleaning and therapeutic phases, retroflexion detection, and classification of out-ofbody segments. Additionally, a novel approach to polyp diagnosis using medically explainable features, rather than a simple final diagnosis, is proposed to enhance clinician training and improve the explainability of computer-aided diagnosis systems. All these methods are designed to be automated and easily integrated into existing polyp detection systems and medical devices"],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10210436/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics and Biomedical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["New automated segment classification, withdrawal time measurement, phase detection, and explainable diagnosis methods for colonoscopy using deep learning"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:40:17Z"}