{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10211445"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10211445","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Design, finite element analysis and experimental testing of a customised instrumented humeral component prototype for a total elbow prosthesis to measure the 6 degree of freedom elbow joint reaction forces in vitro.","abstract":"Total Elbow Arthroplasty (TEA) is an effective procedure for restoring elbow function in patients with conditions like rheumatoid arthritis, complex fractures, and joint instability. However, TEA exhibits a lower long-term survival rate than other joint arthroplasties, often due to complications like aseptic loosening and mechanical failure. This is often caused by the complex forces acting on the elbow during activities of daily living (ADLs). Although previous studies have proposed load thresholds to mitigate TEA failure, direct in vivo measurements of joint forces during ADLs remain unavailable. Existing computational models are limited by assumptions that oversimplify muscle dynamics and joint kinematics, leaving a gap in our understanding real-world joint loading. This thesis presents the development and early-stage validation of a novel prototype: an instrumented humeral component for TEA capable of measuring elbow joint reaction forces and moments across six degrees of freedom during ADLs. A modified Titanium (Ti-6Al-4V) humeral implant was designed with integrated instrumentation and subjected to mechanical fatigue testing to assess its structural durability. Calibration was performed across all six degrees of freedom, followed by in vitro validation under simulated physiological loading conditions. The results demonstrate that the prototype implant can reliably capture joint forces and moments under controlled conditions, providing a proof of concept for future in vivo applications. This work represents a foundational step toward enabling real-time force monitoring in TEA, with the long-term goal of improving implant design, surgical decision-making, and patient outcomes.","abstract_html":"Total Elbow Arthroplasty (TEA) is an effective procedure for restoring elbow function in patients with conditions like rheumatoid arthritis, complex fractures, and joint instability. However, TEA exhibits a lower long-term survival rate than other joint arthroplasties, often due to complications like aseptic loosening and mechanical failure. This is often caused by the complex forces acting on the elbow during activities of daily living (ADLs). Although previous studies have proposed load thresholds to mitigate TEA failure, direct in vivo measurements of joint forces during ADLs remain unavailable. Existing computational models are limited by assumptions that oversimplify muscle dynamics and joint kinematics, leaving a gap in our understanding real-world joint loading. This thesis presents the development and early-stage validation of a novel prototype: an instrumented humeral component for TEA capable of measuring elbow joint reaction forces and moments across six degrees of freedom during ADLs. A modified Titanium (Ti-6Al-4V) humeral implant was designed with integrated instrumentation and subjected to mechanical fatigue testing to assess its structural durability. Calibration was performed across all six degrees of freedom, followed by in vitro validation under simulated physiological loading conditions. The results demonstrate that the prototype implant can reliably capture joint forces and moments under controlled conditions, providing a proof of concept for future in vivo applications. This work represents a foundational step toward enabling real-time force monitoring in TEA, with the long-term goal of improving implant design, surgical decision-making, and patient outcomes.","abstract_has_math":false,"creators":["Basiouny, Marim"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-07","date_published":"2025-07","updated_at":"2026-11-26T07:40:49Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10211445/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10211445/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10211445","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10211445","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Basiouny, Marim"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-07-28"]},{"key":"dc:date.issued","label":"Date","values":["2025-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Division of Surgery and Interventional Science"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10211445/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Total Elbow Arthroplasty (TEA) is an effective procedure for restoring elbow function in patients with conditions like rheumatoid arthritis, complex fractures, and joint instability. However, TEA exhibits a lower long-term survival rate than other joint arthroplasties, often due to complications like aseptic loosening and mechanical failure. This is often caused by the complex forces acting on the elbow during activities of daily living (ADLs). Although previous studies have proposed load thresholds to mitigate TEA failure, direct in vivo measurements of joint forces during ADLs remain unavailable. Existing computational models are limited by assumptions that oversimplify muscle dynamics and joint kinematics, leaving a gap in our understanding real-world joint loading. This thesis presents the development and early-stage validation of a novel prototype: an instrumented humeral component for TEA capable of measuring elbow joint reaction forces and moments across six degrees of freedom during ADLs. A modified Titanium (Ti-6Al-4V) humeral implant was designed with integrated instrumentation and subjected to mechanical fatigue testing to assess its structural durability. Calibration was performed across all six degrees of freedom, followed by in vitro validation under simulated physiological loading conditions. The results demonstrate that the prototype implant can reliably capture joint forces and moments under controlled conditions, providing a proof of concept for future in vivo applications. This work represents a foundational step toward enabling real-time force monitoring in TEA, with the long-term goal of improving implant design, surgical decision-making, and patient outcomes."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Design, finite element analysis and experimental testing of a customised instrumented humeral component prototype for a total elbow prosthesis to measure the 6 degree of freedom elbow joint reaction forces in vitro."]}]}],"canonical_facts":{"dc:creator":["Basiouny, Marim"],"dc:date":["2025-07-28"],"dc:date.issued":["2025-07"],"dc:description.abstract":["Total Elbow Arthroplasty (TEA) is an effective procedure for restoring elbow function in patients with conditions like rheumatoid arthritis, complex fractures, and joint instability. However, TEA exhibits a lower long-term survival rate than other joint arthroplasties, often due to complications like aseptic loosening and mechanical failure. This is often caused by the complex forces acting on the elbow during activities of daily living (ADLs). Although previous studies have proposed load thresholds to mitigate TEA failure, direct in vivo measurements of joint forces during ADLs remain unavailable. Existing computational models are limited by assumptions that oversimplify muscle dynamics and joint kinematics, leaving a gap in our understanding real-world joint loading. This thesis presents the development and early-stage validation of a novel prototype: an instrumented humeral component for TEA capable of measuring elbow joint reaction forces and moments across six degrees of freedom during ADLs. A modified Titanium (Ti-6Al-4V) humeral implant was designed with integrated instrumentation and subjected to mechanical fatigue testing to assess its structural durability. Calibration was performed across all six degrees of freedom, followed by in vitro validation under simulated physiological loading conditions. The results demonstrate that the prototype implant can reliably capture joint forces and moments under controlled conditions, providing a proof of concept for future in vivo applications. This work represents a foundational step toward enabling real-time force monitoring in TEA, with the long-term goal of improving implant design, surgical decision-making, and patient outcomes."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10211445/"],"dc:language":["en","eng"],"dc:publisher.department":["Division of Surgery and Interventional Science"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Design, finite element analysis and experimental testing of a customised instrumented humeral component prototype for a total elbow prosthesis to measure the 6 degree of freedom elbow joint reaction forces in vitro."],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:40:49Z"}