{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10213593"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10213593","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Partial volume correction of 99mTc oncology SPECT imaging via case specific resolution estimation","abstract":"This project aimed to develop a practical method to compensate for the detrimental effect of limited spatial resolution in Tc-99m nuclear medicine oncology imaging. Correction for limited resolution is currently not routinely applied in clinical practice, limiting quantitative accuracy. Literature review identified existing correction strategies, then assessed based on oncology-specific criteria. This found no existing method ideal for oncology. Specifically, many existing correction methods assume that resolution is invariant, which is not a valid assumption for SPECT imaging. Two methods were selected for further investigation. Key factors affecting SPECT resolution were investigated by simulating SPECT acquisition and reconstruction for simple digital phantoms. Practical experiments demonstrated that assuming invariant resolution could introduce inaccuracies in correcting for the effects of limited resolution. Case-specific resolution was estimated using the perturbation method, and subsequently incorporated into correction algorithms. This was tested using a range of datasets including simple digital phantoms and computerised anthropomorphic models - with images generated by analytical simulation. Quantitative accuracy improved for correction algorithms incorporating case-specific resolution. Realistic test datasets developed based on clinical data were used with Monte Carlo software to simulate image acquisition. Two correction algorithms, used with perturbation, were compared with a conventional correction method. Results demonstrated that the Single Target Correction (STC) method with perturbation performed as well as the conventional, Recovery Coefficient (RC), method for regional quantification, with the added advantages of producing an image and capturing heterogeneity within the object of interest. Further work in this area, including assessment of other factors which contribute to quantitative accuracy of quantitative SPECT imaging is required. The work in this thesis could potentially contribute to the practical implementation of correction for the detrimental effect of limited spatial resolution, moving towards images which can more accurately aid the diagnosis, monitoring and treatment of oncology patients.","abstract_html":"This project aimed to develop a practical method to compensate for the detrimental effect of limited spatial resolution in Tc-99m nuclear medicine oncology imaging. Correction for limited resolution is currently not routinely applied in clinical practice, limiting quantitative accuracy. Literature review identified existing correction strategies, then assessed based on oncology-specific criteria. This found no existing method ideal for oncology. Specifically, many existing correction methods assume that resolution is invariant, which is not a valid assumption for SPECT imaging. Two methods were selected for further investigation. Key factors affecting SPECT resolution were investigated by simulating SPECT acquisition and reconstruction for simple digital phantoms. Practical experiments demonstrated that assuming invariant resolution could introduce inaccuracies in correcting for the effects of limited resolution. Case-specific resolution was estimated using the perturbation method, and subsequently incorporated into correction algorithms. This was tested using a range of datasets including simple digital phantoms and computerised anthropomorphic models - with images generated by analytical simulation. Quantitative accuracy improved for correction algorithms incorporating case-specific resolution. Realistic test datasets developed based on clinical data were used with Monte Carlo software to simulate image acquisition. Two correction algorithms, used with perturbation, were compared with a conventional correction method. Results demonstrated that the Single Target Correction (STC) method with perturbation performed as well as the conventional, Recovery Coefficient (RC), method for regional quantification, with the added advantages of producing an image and capturing heterogeneity within the object of interest. Further work in this area, including assessment of other factors which contribute to quantitative accuracy of quantitative SPECT imaging is required. The work in this thesis could potentially contribute to the practical implementation of correction for the detrimental effect of limited spatial resolution, moving towards images which can more accurately aid the diagnosis, monitoring and treatment of oncology patients.","abstract_has_math":false,"creators":["Livingstone Gillen, Rebecca"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":["McQuaid, Sarah","Thielemans, Kris","Hutton, Brian","Denis-Bacelar, Ana"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-09","date_published":"2025-09","updated_at":"2026-11-26T07:41:22Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10213593/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10213593/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10213593","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10213593","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["McQuaid, Sarah","Thielemans, Kris","Hutton, Brian","Denis-Bacelar, Ana"]},{"key":"dc:creator","label":"Author","values":["Livingstone Gillen, Rebecca"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-09-28"]},{"key":"dc:date.issued","label":"Date","values":["2025-09"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Nuclear Medicine"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10213593/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This project aimed to develop a practical method to compensate for the detrimental effect of limited spatial resolution in Tc-99m nuclear medicine oncology imaging. Correction for limited resolution is currently not routinely applied in clinical practice, limiting quantitative accuracy. Literature review identified existing correction strategies, then assessed based on oncology-specific criteria. This found no existing method ideal for oncology. Specifically, many existing correction methods assume that resolution is invariant, which is not a valid assumption for SPECT imaging. Two methods were selected for further investigation. Key factors affecting SPECT resolution were investigated by simulating SPECT acquisition and reconstruction for simple digital phantoms. Practical experiments demonstrated that assuming invariant resolution could introduce inaccuracies in correcting for the effects of limited resolution. Case-specific resolution was estimated using the perturbation method, and subsequently incorporated into correction algorithms. This was tested using a range of datasets including simple digital phantoms and computerised anthropomorphic models - with images generated by analytical simulation. Quantitative accuracy improved for correction algorithms incorporating case-specific resolution. Realistic test datasets developed based on clinical data were used with Monte Carlo software to simulate image acquisition. Two correction algorithms, used with perturbation, were compared with a conventional correction method. Results demonstrated that the Single Target Correction (STC) method with perturbation performed as well as the conventional, Recovery Coefficient (RC), method for regional quantification, with the added advantages of producing an image and capturing heterogeneity within the object of interest. Further work in this area, including assessment of other factors which contribute to quantitative accuracy of quantitative SPECT imaging is required. The work in this thesis could potentially contribute to the practical implementation of correction for the detrimental effect of limited spatial resolution, moving towards images which can more accurately aid the diagnosis, monitoring and treatment of oncology patients."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Partial volume correction of 99mTc oncology SPECT imaging via case specific resolution estimation"]}]}],"canonical_facts":{"dc:contributor":["McQuaid, Sarah","Thielemans, Kris","Hutton, Brian","Denis-Bacelar, Ana"],"dc:creator":["Livingstone Gillen, Rebecca"],"dc:date":["2025-09-28"],"dc:date.issued":["2025-09"],"dc:description.abstract":["This project aimed to develop a practical method to compensate for the detrimental effect of limited spatial resolution in Tc-99m nuclear medicine oncology imaging. Correction for limited resolution is currently not routinely applied in clinical practice, limiting quantitative accuracy. Literature review identified existing correction strategies, then assessed based on oncology-specific criteria. This found no existing method ideal for oncology. Specifically, many existing correction methods assume that resolution is invariant, which is not a valid assumption for SPECT imaging. Two methods were selected for further investigation. Key factors affecting SPECT resolution were investigated by simulating SPECT acquisition and reconstruction for simple digital phantoms. Practical experiments demonstrated that assuming invariant resolution could introduce inaccuracies in correcting for the effects of limited resolution. Case-specific resolution was estimated using the perturbation method, and subsequently incorporated into correction algorithms. This was tested using a range of datasets including simple digital phantoms and computerised anthropomorphic models - with images generated by analytical simulation. Quantitative accuracy improved for correction algorithms incorporating case-specific resolution. Realistic test datasets developed based on clinical data were used with Monte Carlo software to simulate image acquisition. Two correction algorithms, used with perturbation, were compared with a conventional correction method. Results demonstrated that the Single Target Correction (STC) method with perturbation performed as well as the conventional, Recovery Coefficient (RC), method for regional quantification, with the added advantages of producing an image and capturing heterogeneity within the object of interest. Further work in this area, including assessment of other factors which contribute to quantitative accuracy of quantitative SPECT imaging is required. The work in this thesis could potentially contribute to the practical implementation of correction for the detrimental effect of limited spatial resolution, moving towards images which can more accurately aid the diagnosis, monitoring and treatment of oncology patients."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10213593/"],"dc:language":["en","eng"],"dc:publisher.department":["Institute of Nuclear Medicine"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Partial volume correction of 99mTc oncology SPECT imaging via case specific resolution estimation"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:41:22Z"}