{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10219684"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10219684","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Supporting Clinical Decision-Making in Optometry: OCT Imaging, Artificial Intelligence, and the Integration of Technology in Practice","abstract":"Ophthalmic services in the UK face increasing pressure, with referrals from primary care optometrists contributing to hospital eye service demand. Optical coherence tomography (OCT) enables earlier detection of retinal abnormalities but can also highlight benign findings that drive false-positive referrals. These challenges have prompted interest in artificial intelligence as a form of clinical decision support (AI-CDSS). This thesis used a mixed-methods approach to investigate both the clinical and human-computer interaction aspects of optometrists’ referral decision-making with OCT and the potential role of AI-CDSS. A quantitative systematic review evaluated referral accuracy and found significant variation between conditions, with false-positive rates decreasing with experience (6.2% per year since registration, p < 0.001). A second mixed-methods review examined interventions to reduce false positives, showing variable effectiveness and underscoring the potential of AI. Interviews with 20 primary care optometrists explored how OCT is integrated into practice, how referral decisions are made, and how AI-CDSS could be best designed. Four distinct practitioner profiles were identified: Newly qualified (Type 1), OCT-integrated (Type 2), experienced hesitant (Type 3), and experienced early adopters (Type 4). These profiles reflect differences in experience and confidence. Thematic analysis highlighted the interplay of clinical, contextual, and patient-specific factors in referrals. Another novel contribution is the application of proactive and reactive information-seeking behaviours to OCT interpretation: proactive seeking benefits from tools that support anticipation and learning, while reactive seeking requires immediate support at the point of uncertainty. The thesis also examined optometrists’ interactions with AI in ambiguous cases. A reanalysis of quantitative data showed that AI outputs, particularly segmentation overlays, influenced diagnostic confidence and trust even when inaccurate. While valued as interpretative aids these findings highlight the importance of careful output design. This research advances HCI by deriving design considerations for safe and usable AI systems in primary care optometry. It contributes to optometry by characterising real-world OCT use and identifying practitioner experiences and learning patterns that shape diagnostic decision-making and information needs. Together, these findings provide actionable insights for the responsible design and deployment of AI-CDSS in primary eye care.","abstract_html":"Ophthalmic services in the UK face increasing pressure, with referrals from primary care optometrists contributing to hospital eye service demand. Optical coherence tomography (OCT) enables earlier detection of retinal abnormalities but can also highlight benign findings that drive false-positive referrals. These challenges have prompted interest in artificial intelligence as a form of clinical decision support (AI-CDSS). This thesis used a mixed-methods approach to investigate both the clinical and human-computer interaction aspects of optometrists’ referral decision-making with OCT and the potential role of AI-CDSS. A quantitative systematic review evaluated referral accuracy and found significant variation between conditions, with false-positive rates decreasing with experience (6.2% per year since registration, p &lt; 0.001). A second mixed-methods review examined interventions to reduce false positives, showing variable effectiveness and underscoring the potential of AI. Interviews with 20 primary care optometrists explored how OCT is integrated into practice, how referral decisions are made, and how AI-CDSS could be best designed. Four distinct practitioner profiles were identified: Newly qualified (Type 1), OCT-integrated (Type 2), experienced hesitant (Type 3), and experienced early adopters (Type 4). These profiles reflect differences in experience and confidence. Thematic analysis highlighted the interplay of clinical, contextual, and patient-specific factors in referrals. Another novel contribution is the application of proactive and reactive information-seeking behaviours to OCT interpretation: proactive seeking benefits from tools that support anticipation and learning, while reactive seeking requires immediate support at the point of uncertainty. The thesis also examined optometrists’ interactions with AI in ambiguous cases. A reanalysis of quantitative data showed that AI outputs, particularly segmentation overlays, influenced diagnostic confidence and trust even when inaccurate. While valued as interpretative aids these findings highlight the importance of careful output design. This research advances HCI by deriving design considerations for safe and usable AI systems in primary care optometry. It contributes to optometry by characterising real-world OCT use and identifying practitioner experiences and learning patterns that shape diagnostic decision-making and information needs. Together, these findings provide actionable insights for the responsible design and deployment of AI-CDSS in primary eye care.","abstract_has_math":false,"creators":["Carmichael, Josie"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-12","date_published":"2025-12","updated_at":"2026-11-26T07:42:27Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10219684/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10219684/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10219684","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10219684","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Carmichael, Josie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-12-28"]},{"key":"dc:date.issued","label":"Date","values":["2025-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics & Biomedical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10219684/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ophthalmic services in the UK face increasing pressure, with referrals from primary care optometrists contributing to hospital eye service demand. Optical coherence tomography (OCT) enables earlier detection of retinal abnormalities but can also highlight benign findings that drive false-positive referrals. These challenges have prompted interest in artificial intelligence as a form of clinical decision support (AI-CDSS). This thesis used a mixed-methods approach to investigate both the clinical and human-computer interaction aspects of optometrists’ referral decision-making with OCT and the potential role of AI-CDSS. A quantitative systematic review evaluated referral accuracy and found significant variation between conditions, with false-positive rates decreasing with experience (6.2% per year since registration, p < 0.001). A second mixed-methods review examined interventions to reduce false positives, showing variable effectiveness and underscoring the potential of AI. Interviews with 20 primary care optometrists explored how OCT is integrated into practice, how referral decisions are made, and how AI-CDSS could be best designed. Four distinct practitioner profiles were identified: Newly qualified (Type 1), OCT-integrated (Type 2), experienced hesitant (Type 3), and experienced early adopters (Type 4). These profiles reflect differences in experience and confidence. Thematic analysis highlighted the interplay of clinical, contextual, and patient-specific factors in referrals. Another novel contribution is the application of proactive and reactive information-seeking behaviours to OCT interpretation: proactive seeking benefits from tools that support anticipation and learning, while reactive seeking requires immediate support at the point of uncertainty. The thesis also examined optometrists’ interactions with AI in ambiguous cases. A reanalysis of quantitative data showed that AI outputs, particularly segmentation overlays, influenced diagnostic confidence and trust even when inaccurate. While valued as interpretative aids these findings highlight the importance of careful output design. This research advances HCI by deriving design considerations for safe and usable AI systems in primary care optometry. It contributes to optometry by characterising real-world OCT use and identifying practitioner experiences and learning patterns that shape diagnostic decision-making and information needs. Together, these findings provide actionable insights for the responsible design and deployment of AI-CDSS in primary eye care."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Supporting Clinical Decision-Making in Optometry: OCT Imaging, Artificial Intelligence, and the Integration of Technology in Practice"]}]}],"canonical_facts":{"dc:creator":["Carmichael, Josie"],"dc:date":["2025-12-28"],"dc:date.issued":["2025-12"],"dc:description.abstract":["Ophthalmic services in the UK face increasing pressure, with referrals from primary care optometrists contributing to hospital eye service demand. Optical coherence tomography (OCT) enables earlier detection of retinal abnormalities but can also highlight benign findings that drive false-positive referrals. These challenges have prompted interest in artificial intelligence as a form of clinical decision support (AI-CDSS). This thesis used a mixed-methods approach to investigate both the clinical and human-computer interaction aspects of optometrists’ referral decision-making with OCT and the potential role of AI-CDSS. A quantitative systematic review evaluated referral accuracy and found significant variation between conditions, with false-positive rates decreasing with experience (6.2% per year since registration, p < 0.001). A second mixed-methods review examined interventions to reduce false positives, showing variable effectiveness and underscoring the potential of AI. Interviews with 20 primary care optometrists explored how OCT is integrated into practice, how referral decisions are made, and how AI-CDSS could be best designed. Four distinct practitioner profiles were identified: Newly qualified (Type 1), OCT-integrated (Type 2), experienced hesitant (Type 3), and experienced early adopters (Type 4). These profiles reflect differences in experience and confidence. Thematic analysis highlighted the interplay of clinical, contextual, and patient-specific factors in referrals. Another novel contribution is the application of proactive and reactive information-seeking behaviours to OCT interpretation: proactive seeking benefits from tools that support anticipation and learning, while reactive seeking requires immediate support at the point of uncertainty. The thesis also examined optometrists’ interactions with AI in ambiguous cases. A reanalysis of quantitative data showed that AI outputs, particularly segmentation overlays, influenced diagnostic confidence and trust even when inaccurate. While valued as interpretative aids these findings highlight the importance of careful output design. This research advances HCI by deriving design considerations for safe and usable AI systems in primary care optometry. It contributes to optometry by characterising real-world OCT use and identifying practitioner experiences and learning patterns that shape diagnostic decision-making and information needs. Together, these findings provide actionable insights for the responsible design and deployment of AI-CDSS in primary eye care."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10219684/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics & Biomedical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Supporting Clinical Decision-Making in Optometry: OCT Imaging, Artificial Intelligence, and the Integration of Technology in Practice"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:42:27Z"}