{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10222381"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10222381","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Scattering and mode conversion of guided waves at part-thickness defects for baseline-free SHM of plate structures","abstract":"To ensure aircraft safety, non-destructive evaluation (NDE) and structural health monitoring (SHM) methods are applied for the early detection of defects such as part-thickness fatigue cracks. Guided ultrasonic waves can propagate significant distances along large plate structures, allowing the monitoring with a limited number of sensors. To develop SHM based on guided waves, it is essential to obtain a comprehensive understanding of the interaction of guided waves with damage. While the scattering of single guided wave modes has been extensively studied, research on mode conversion between guided wave modes has been limited. The understanding of the mode conversion between the guided wave modes could be employed to develop and improve baseline-free SHM localization and detection algorithms under changing environmental conditions. In this thesis, the scattering and mode conversion between the fundamental Lamb wave modes (S0 and A0 modes) at part-thickness notches in an isotropic plate were systematically studied. 3D Finite Element (FE) modelling and experimental validation were conducted with good agreement and the influence of variation of parameters such as damage size (length and depth) and incident direction on the mode conversion was studied and quantified. The maximum mode conversion occurred for ¾ defect depth and the amplitude of the mode converted guided wave mode mostly increased linearly as the defect length increased. A baseline-free SHM algorithm employing guided wave mode conversion (S0-A0 mode) was developed based on the improved understanding of the mode conversion. From both FE simulations and experiments defects within the area of large plate structures covered by the distributed sensors could be accurately localized, based on the time difference of arrival algorithm. The temperature effect on the detection results was investigated to verify that the baseline-free algorithm worked accurately independent of temperature variation, overcoming one of the limitations of traditional baseline-subtraction SHM.","abstract_html":"To ensure aircraft safety, non-destructive evaluation (NDE) and structural health monitoring (SHM) methods are applied for the early detection of defects such as part-thickness fatigue cracks. Guided ultrasonic waves can propagate significant distances along large plate structures, allowing the monitoring with a limited number of sensors. To develop SHM based on guided waves, it is essential to obtain a comprehensive understanding of the interaction of guided waves with damage. While the scattering of single guided wave modes has been extensively studied, research on mode conversion between guided wave modes has been limited. The understanding of the mode conversion between the guided wave modes could be employed to develop and improve baseline-free SHM localization and detection algorithms under changing environmental conditions. In this thesis, the scattering and mode conversion between the fundamental Lamb wave modes (S0 and A0 modes) at part-thickness notches in an isotropic plate were systematically studied. 3D Finite Element (FE) modelling and experimental validation were conducted with good agreement and the influence of variation of parameters such as damage size (length and depth) and incident direction on the mode conversion was studied and quantified. The maximum mode conversion occurred for ¾ defect depth and the amplitude of the mode converted guided wave mode mostly increased linearly as the defect length increased. A baseline-free SHM algorithm employing guided wave mode conversion (S0-A0 mode) was developed based on the improved understanding of the mode conversion. From both FE simulations and experiments defects within the area of large plate structures covered by the distributed sensors could be accurately localized, based on the time difference of arrival algorithm. The temperature effect on the detection results was investigated to verify that the baseline-free algorithm worked accurately independent of temperature variation, overcoming one of the limitations of traditional baseline-subtraction SHM.","abstract_has_math":false,"creators":["Li, Lijian"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-03","date_published":"2026-03","updated_at":"2026-11-26T07:42:59Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10222381/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10222381/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10222381","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10222381","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Li, Lijian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-03-28"]},{"key":"dc:date.issued","label":"Date","values":["2026-03"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Mechanical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10222381/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To ensure aircraft safety, non-destructive evaluation (NDE) and structural health monitoring (SHM) methods are applied for the early detection of defects such as part-thickness fatigue cracks. Guided ultrasonic waves can propagate significant distances along large plate structures, allowing the monitoring with a limited number of sensors. To develop SHM based on guided waves, it is essential to obtain a comprehensive understanding of the interaction of guided waves with damage. While the scattering of single guided wave modes has been extensively studied, research on mode conversion between guided wave modes has been limited. The understanding of the mode conversion between the guided wave modes could be employed to develop and improve baseline-free SHM localization and detection algorithms under changing environmental conditions. In this thesis, the scattering and mode conversion between the fundamental Lamb wave modes (S0 and A0 modes) at part-thickness notches in an isotropic plate were systematically studied. 3D Finite Element (FE) modelling and experimental validation were conducted with good agreement and the influence of variation of parameters such as damage size (length and depth) and incident direction on the mode conversion was studied and quantified. The maximum mode conversion occurred for ¾ defect depth and the amplitude of the mode converted guided wave mode mostly increased linearly as the defect length increased. A baseline-free SHM algorithm employing guided wave mode conversion (S0-A0 mode) was developed based on the improved understanding of the mode conversion. From both FE simulations and experiments defects within the area of large plate structures covered by the distributed sensors could be accurately localized, based on the time difference of arrival algorithm. The temperature effect on the detection results was investigated to verify that the baseline-free algorithm worked accurately independent of temperature variation, overcoming one of the limitations of traditional baseline-subtraction SHM."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Scattering and mode conversion of guided waves at part-thickness defects for baseline-free SHM of plate structures"]}]}],"canonical_facts":{"dc:creator":["Li, Lijian"],"dc:date":["2026-03-28"],"dc:date.issued":["2026-03"],"dc:description.abstract":["To ensure aircraft safety, non-destructive evaluation (NDE) and structural health monitoring (SHM) methods are applied for the early detection of defects such as part-thickness fatigue cracks. Guided ultrasonic waves can propagate significant distances along large plate structures, allowing the monitoring with a limited number of sensors. To develop SHM based on guided waves, it is essential to obtain a comprehensive understanding of the interaction of guided waves with damage. While the scattering of single guided wave modes has been extensively studied, research on mode conversion between guided wave modes has been limited. The understanding of the mode conversion between the guided wave modes could be employed to develop and improve baseline-free SHM localization and detection algorithms under changing environmental conditions. In this thesis, the scattering and mode conversion between the fundamental Lamb wave modes (S0 and A0 modes) at part-thickness notches in an isotropic plate were systematically studied. 3D Finite Element (FE) modelling and experimental validation were conducted with good agreement and the influence of variation of parameters such as damage size (length and depth) and incident direction on the mode conversion was studied and quantified. The maximum mode conversion occurred for ¾ defect depth and the amplitude of the mode converted guided wave mode mostly increased linearly as the defect length increased. A baseline-free SHM algorithm employing guided wave mode conversion (S0-A0 mode) was developed based on the improved understanding of the mode conversion. From both FE simulations and experiments defects within the area of large plate structures covered by the distributed sensors could be accurately localized, based on the time difference of arrival algorithm. The temperature effect on the detection results was investigated to verify that the baseline-free algorithm worked accurately independent of temperature variation, overcoming one of the limitations of traditional baseline-subtraction SHM."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10222381/"],"dc:language":["en","eng"],"dc:publisher.department":["Mechanical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Scattering and mode conversion of guided waves at part-thickness defects for baseline-free SHM of plate structures"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:42:59Z"}