{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10229948"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10229948","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Housing Energy Efficiency and Health: A National Longitudinal Data Linkage Study","abstract":"Background: Poor housing quality and cold indoor temperatures significantly affect respiratory conditions and health inequalities. This thesis aimed to clarify the complex relationship between housing energy efficiency (EE) measures and common respiratory health conditions. Methods: The thesis research included: - A systematic review (1980-2024) of evidence on cold indoor temperatures, EE and respiratory health. - Piloting a novel linkage of dwelling-level Energy Performance Certificate (EPC) data with routine health records within the Welsh Secure Anonymised Information Linkage Databank. - A longitudinal study using this linkage to analyse associations between wall insulation and EPC ratings and GP-diagnosed asthma/COPD through Cox regression. Findings: The systematic review found consistent evidence that cold indoor temperatures increase respiratory symptoms, but inconsistent evidence regarding impacts of EE interventions. The survival analysis of 636,640 (asthma) and 726,925 (COPD) individuals found that living in a high EE home (EPC bands A-C vs. E-G) was associated with a reduced incidence of both asthma (HR 0.955; 95% C.I. 0.912-0.999) and COPD (HR 0.897; 95% CI 0.843-0.954), as was moderate energy efficiency (band D vs. E-G) for COPD (HR 0.914; 95% CI. 0.867-0.963), in adjusted analyses. Specific wall insulation types were not associated with asthma incidence, but cavity wall insulation was associated with reduced COPD incidence (HR 0.938 (95%CI 0.896- 0.982). Attributable fraction calculations suggested that improving all E-G homes in Wales to A-C standards could potentially prevent around 10% of new cases of COPD. Non- and ex- smokers experienced greater protective effects of higher EE on COPD incidence, with no reduction amongst current smokers. Conclusions: This thesis demonstrates the value of large-scale household-level linked datasets for housing and health research. Higher overall dwelling energy efficiency appears protective for both COPD and asthma. The finding of a differential effect by smoking status likely highlights the importance of ventilation and indoor air quality. This thesis strengthens the case for holistic retrofit and building policies, and for health-focused evaluations.","abstract_html":"Background: Poor housing quality and cold indoor temperatures significantly affect respiratory conditions and health inequalities. This thesis aimed to clarify the complex relationship between housing energy efficiency (EE) measures and common respiratory health conditions. Methods: The thesis research included: - A systematic review (1980-2024) of evidence on cold indoor temperatures, EE and respiratory health. - Piloting a novel linkage of dwelling-level Energy Performance Certificate (EPC) data with routine health records within the Welsh Secure Anonymised Information Linkage Databank. - A longitudinal study using this linkage to analyse associations between wall insulation and EPC ratings and GP-diagnosed asthma/COPD through Cox regression. Findings: The systematic review found consistent evidence that cold indoor temperatures increase respiratory symptoms, but inconsistent evidence regarding impacts of EE interventions. The survival analysis of 636,640 (asthma) and 726,925 (COPD) individuals found that living in a high EE home (EPC bands A-C vs. E-G) was associated with a reduced incidence of both asthma (HR 0.955; 95% C.I. 0.912-0.999) and COPD (HR 0.897; 95% CI 0.843-0.954), as was moderate energy efficiency (band D vs. E-G) for COPD (HR 0.914; 95% CI. 0.867-0.963), in adjusted analyses. Specific wall insulation types were not associated with asthma incidence, but cavity wall insulation was associated with reduced COPD incidence (HR 0.938 (95%CI 0.896- 0.982). Attributable fraction calculations suggested that improving all E-G homes in Wales to A-C standards could potentially prevent around 10% of new cases of COPD. Non- and ex- smokers experienced greater protective effects of higher EE on COPD incidence, with no reduction amongst current smokers. Conclusions: This thesis demonstrates the value of large-scale household-level linked datasets for housing and health research. Higher overall dwelling energy efficiency appears protective for both COPD and asthma. The finding of a differential effect by smoking status likely highlights the importance of ventilation and indoor air quality. This thesis strengthens the case for holistic retrofit and building policies, and for health-focused evaluations.","abstract_has_math":false,"creators":["Braithwaite, Isobel"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Sheringham, Jessica","Denaxas, Spiros","Mavrogianni, Anna","Katsoulis, Michail","Aldridge, Robert"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-08","date_published":"2026-08","updated_at":"2026-11-26T07:44:34Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10229948/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10229948/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10229948","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10229948","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sheringham, Jessica","Denaxas, Spiros","Mavrogianni, Anna","Katsoulis, Michail","Aldridge, Robert"]},{"key":"dc:creator","label":"Author","values":["Braithwaite, Isobel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-08-28"]},{"key":"dc:date.issued","label":"Date","values":["2026-08"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Primary Care and Population Health"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10229948/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Background: Poor housing quality and cold indoor temperatures significantly affect respiratory conditions and health inequalities. This thesis aimed to clarify the complex relationship between housing energy efficiency (EE) measures and common respiratory health conditions. Methods: The thesis research included: - A systematic review (1980-2024) of evidence on cold indoor temperatures, EE and respiratory health. - Piloting a novel linkage of dwelling-level Energy Performance Certificate (EPC) data with routine health records within the Welsh Secure Anonymised Information Linkage Databank. - A longitudinal study using this linkage to analyse associations between wall insulation and EPC ratings and GP-diagnosed asthma/COPD through Cox regression. Findings: The systematic review found consistent evidence that cold indoor temperatures increase respiratory symptoms, but inconsistent evidence regarding impacts of EE interventions. The survival analysis of 636,640 (asthma) and 726,925 (COPD) individuals found that living in a high EE home (EPC bands A-C vs. E-G) was associated with a reduced incidence of both asthma (HR 0.955; 95% C.I. 0.912-0.999) and COPD (HR 0.897; 95% CI 0.843-0.954), as was moderate energy efficiency (band D vs. E-G) for COPD (HR 0.914; 95% CI. 0.867-0.963), in adjusted analyses. Specific wall insulation types were not associated with asthma incidence, but cavity wall insulation was associated with reduced COPD incidence (HR 0.938 (95%CI 0.896- 0.982). Attributable fraction calculations suggested that improving all E-G homes in Wales to A-C standards could potentially prevent around 10% of new cases of COPD. Non- and ex- smokers experienced greater protective effects of higher EE on COPD incidence, with no reduction amongst current smokers. Conclusions: This thesis demonstrates the value of large-scale household-level linked datasets for housing and health research. Higher overall dwelling energy efficiency appears protective for both COPD and asthma. The finding of a differential effect by smoking status likely highlights the importance of ventilation and indoor air quality. This thesis strengthens the case for holistic retrofit and building policies, and for health-focused evaluations."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Housing Energy Efficiency and Health: A National Longitudinal Data Linkage Study"]}]}],"canonical_facts":{"dc:contributor":["Sheringham, Jessica","Denaxas, Spiros","Mavrogianni, Anna","Katsoulis, Michail","Aldridge, Robert"],"dc:creator":["Braithwaite, Isobel"],"dc:date":["2026-08-28"],"dc:date.issued":["2026-08"],"dc:description.abstract":["Background: Poor housing quality and cold indoor temperatures significantly affect respiratory conditions and health inequalities. This thesis aimed to clarify the complex relationship between housing energy efficiency (EE) measures and common respiratory health conditions. Methods: The thesis research included: - A systematic review (1980-2024) of evidence on cold indoor temperatures, EE and respiratory health. - Piloting a novel linkage of dwelling-level Energy Performance Certificate (EPC) data with routine health records within the Welsh Secure Anonymised Information Linkage Databank. - A longitudinal study using this linkage to analyse associations between wall insulation and EPC ratings and GP-diagnosed asthma/COPD through Cox regression. Findings: The systematic review found consistent evidence that cold indoor temperatures increase respiratory symptoms, but inconsistent evidence regarding impacts of EE interventions. The survival analysis of 636,640 (asthma) and 726,925 (COPD) individuals found that living in a high EE home (EPC bands A-C vs. E-G) was associated with a reduced incidence of both asthma (HR 0.955; 95% C.I. 0.912-0.999) and COPD (HR 0.897; 95% CI 0.843-0.954), as was moderate energy efficiency (band D vs. E-G) for COPD (HR 0.914; 95% CI. 0.867-0.963), in adjusted analyses. Specific wall insulation types were not associated with asthma incidence, but cavity wall insulation was associated with reduced COPD incidence (HR 0.938 (95%CI 0.896- 0.982). Attributable fraction calculations suggested that improving all E-G homes in Wales to A-C standards could potentially prevent around 10% of new cases of COPD. Non- and ex- smokers experienced greater protective effects of higher EE on COPD incidence, with no reduction amongst current smokers. Conclusions: This thesis demonstrates the value of large-scale household-level linked datasets for housing and health research. Higher overall dwelling energy efficiency appears protective for both COPD and asthma. The finding of a differential effect by smoking status likely highlights the importance of ventilation and indoor air quality. This thesis strengthens the case for holistic retrofit and building policies, and for health-focused evaluations."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10229948/"],"dc:language":["en","eng"],"dc:publisher.department":["Primary Care and Population Health"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Housing Energy Efficiency and Health: A National Longitudinal Data Linkage Study"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:44:34Z"}