{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:1398304"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:1398304","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"End Point Detection in Reactive Ion Etching","abstract":"End-point detection for deep reactive ion etch of silicon in the semiconductor industry has been investigated with a focus on statistical treatments on optical emission spectroscopy. The data reduction technique Principal components analysis (PCA) has been briefly reviewed and analysed as an introduction to independent component analysis (ICA). ICA is a computational dimension reduction technique capable of separating multivariate data into single components. In this instance PCA and ICA are used in to combine the spectral channels of optical emission spectroscopy of plasma processes into a reduced number of components. ICA is based on a fixed-point iteration process maximizing non-gaussianity as a measure of statistical independence. ICA has been shown to offer an improvement in signal to noise ratio when compared to principal component analysis, which has been widely used in previous studies into end-pointing. In addition to the end-point investigation, a study was carried out into the fabrication of arrays of free standing silicon nanorods. The fabrication process consisted of an electron beam lithograpy stage to pattern bare silicon, followed by a deep reactive ion etch - using the Bosch process - to create the nanorods. A variety of difference diameter nanorods, with a selection of pitch dimensions were created using this technique.","abstract_html":"End-point detection for deep reactive ion etch of silicon in the semiconductor industry has been investigated with a focus on statistical treatments on optical emission spectroscopy. The data reduction technique Principal components analysis (PCA) has been briefly reviewed and analysed as an introduction to independent component analysis (ICA). ICA is a computational dimension reduction technique capable of separating multivariate data into single components. In this instance PCA and ICA are used in to combine the spectral channels of optical emission spectroscopy of plasma processes into a reduced number of components. ICA is based on a fixed-point iteration process maximizing non-gaussianity as a measure of statistical independence. ICA has been shown to offer an improvement in signal to noise ratio when compared to principal component analysis, which has been widely used in previous studies into end-pointing. In addition to the end-point investigation, a study was carried out into the fabrication of arrays of free standing silicon nanorods. The fabrication process consisted of an electron beam lithograpy stage to pattern bare silicon, followed by a deep reactive ion etch - using the Bosch process - to create the nanorods. A variety of difference diameter nanorods, with a selection of pitch dimensions were created using this technique.","abstract_has_math":false,"creators":["Pugh, CJ"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-04","date_published":"2013-04","updated_at":"2026-11-26T03:33:17Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/1398304/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/1398304/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A1398304","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A1398304","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pugh, CJ"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-04-28"]},{"key":"dc:date.issued","label":"Date","values":["2013-04"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Electronic and Electrical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/1398304/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["End-point detection for deep reactive ion etch of silicon in the semiconductor industry has been investigated with a focus on statistical treatments on optical emission spectroscopy. The data reduction technique Principal components analysis (PCA) has been briefly reviewed and analysed as an introduction to independent component analysis (ICA). ICA is a computational dimension reduction technique capable of separating multivariate data into single components. In this instance PCA and ICA are used in to combine the spectral channels of optical emission spectroscopy of plasma processes into a reduced number of components. ICA is based on a fixed-point iteration process maximizing non-gaussianity as a measure of statistical independence. ICA has been shown to offer an improvement in signal to noise ratio when compared to principal component analysis, which has been widely used in previous studies into end-pointing. In addition to the end-point investigation, a study was carried out into the fabrication of arrays of free standing silicon nanorods. The fabrication process consisted of an electron beam lithograpy stage to pattern bare silicon, followed by a deep reactive ion etch - using the Bosch process - to create the nanorods. A variety of difference diameter nanorods, with a selection of pitch dimensions were created using this technique."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["End Point Detection in Reactive Ion Etching"]}]}],"canonical_facts":{"dc:creator":["Pugh, CJ"],"dc:date":["2013-04-28"],"dc:date.issued":["2013-04"],"dc:description.abstract":["End-point detection for deep reactive ion etch of silicon in the semiconductor industry has been investigated with a focus on statistical treatments on optical emission spectroscopy. The data reduction technique Principal components analysis (PCA) has been briefly reviewed and analysed as an introduction to independent component analysis (ICA). ICA is a computational dimension reduction technique capable of separating multivariate data into single components. In this instance PCA and ICA are used in to combine the spectral channels of optical emission spectroscopy of plasma processes into a reduced number of components. ICA is based on a fixed-point iteration process maximizing non-gaussianity as a measure of statistical independence. ICA has been shown to offer an improvement in signal to noise ratio when compared to principal component analysis, which has been widely used in previous studies into end-pointing. In addition to the end-point investigation, a study was carried out into the fabrication of arrays of free standing silicon nanorods. The fabrication process consisted of an electron beam lithograpy stage to pattern bare silicon, followed by a deep reactive ion etch - using the Bosch process - to create the nanorods. A variety of difference diameter nanorods, with a selection of pitch dimensions were created using this technique."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/1398304/"],"dc:language":["en","eng"],"dc:publisher.department":["Electronic and Electrical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["End Point Detection in Reactive Ion Etching"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T03:33:17Z"}