{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:1406401"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:1406401","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Assessment of the 3D spatial distribution of the Calcium/Phosphorus ratio in bone","abstract":"The purpose of this study was the development of a technique for the non-invasive assessment of the 3D spatial distribution of the Ca/P ratio in bone, which can be applied in a conventional computed-tomography (CT) system, to investigate the variation of Ca/P ratio in healthy and osteoporotic bone, and to potentially enhance osteoporosis understanding and diagnosis. Three-material mass-fraction decomposition CT dual energy analysis (CT-DEA) was developed and optimised for the assessment of Ca/P ratio. As part of this process, density values are provided as a bi-product. The technique was optimised and experimentally applied through a microCT system. The target of the optimisation was to achieve a precision of better than 0.09 in the Ca/P ratio, in order to be able to distinguish between all healthy and osteoporotic regions. Electron dispersive X-ray spectroscopy (EDX) was used to evaluate the performance of CT-DEA on bone apatite. Ca/P ratio measurements were made on the same healthy and inflammation mediated osteoporotic (IMO) rabbit cortical bone surfaces, using CT-DEA and EDX. The mean di fference in the Ca/P ratio between the two techniques was 0.11± 0.08 (8 6%) and the correlation was R²=0.69, suggesting su cient con dence in the experimental capabilities of the CT-DEA technique. Healthy and IMO rabbit, both collagen-free and intact, cortical bone samples were assessed by CT-DEA. Qualitative analysis of the results involved the production of Ca/P ratio and density distribution maps. Quantitative analysis involved the quanti cation of the Ca/P ratio and density across the whole sample and in volumes of interest, as well as the low Ca/P ratio proportion in each sample. Furthermore, a 3D region growing technique was used to study the uniformity of Ca/P ratio in the samples. Results showed di erences in both density and Ca/P ratio between healthy and IMO bone samples, supporting their use as possible osteoporosis indicators and the use of the developed technique for further studies.","abstract_html":"The purpose of this study was the development of a technique for the non-invasive assessment of the 3D spatial distribution of the Ca/P ratio in bone, which can be applied in a conventional computed-tomography (CT) system, to investigate the variation of Ca/P ratio in healthy and osteoporotic bone, and to potentially enhance osteoporosis understanding and diagnosis. Three-material mass-fraction decomposition CT dual energy analysis (CT-DEA) was developed and optimised for the assessment of Ca/P ratio. As part of this process, density values are provided as a bi-product. The technique was optimised and experimentally applied through a microCT system. The target of the optimisation was to achieve a precision of better than 0.09 in the Ca/P ratio, in order to be able to distinguish between all healthy and osteoporotic regions. Electron dispersive X-ray spectroscopy (EDX) was used to evaluate the performance of CT-DEA on bone apatite. Ca/P ratio measurements were made on the same healthy and inflammation mediated osteoporotic (IMO) rabbit cortical bone surfaces, using CT-DEA and EDX. The mean di fference in the Ca/P ratio between the two techniques was 0.11± 0.08 (8 6%) and the correlation was R²=0.69, suggesting su cient con dence in the experimental capabilities of the CT-DEA technique. Healthy and IMO rabbit, both collagen-free and intact, cortical bone samples were assessed by CT-DEA. Qualitative analysis of the results involved the production of Ca/P ratio and density distribution maps. Quantitative analysis involved the quanti cation of the Ca/P ratio and density across the whole sample and in volumes of interest, as well as the low Ca/P ratio proportion in each sample. Furthermore, a 3D region growing technique was used to study the uniformity of Ca/P ratio in the samples. Results showed di erences in both density and Ca/P ratio between healthy and IMO bone samples, supporting their use as possible osteoporosis indicators and the use of the developed technique for further studies.","abstract_has_math":false,"creators":["Hadjipanteli, A"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-09","date_published":"2013-09","updated_at":"2026-11-26T03:33:55Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/1406401/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/1406401/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A1406401","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A1406401","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hadjipanteli, A"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-09-28"]},{"key":"dc:date.issued","label":"Date","values":["2013-09"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics and Bioengineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/1406401/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was the development of a technique for the non-invasive assessment of the 3D spatial distribution of the Ca/P ratio in bone, which can be applied in a conventional computed-tomography (CT) system, to investigate the variation of Ca/P ratio in healthy and osteoporotic bone, and to potentially enhance osteoporosis understanding and diagnosis. Three-material mass-fraction decomposition CT dual energy analysis (CT-DEA) was developed and optimised for the assessment of Ca/P ratio. As part of this process, density values are provided as a bi-product. The technique was optimised and experimentally applied through a microCT system. The target of the optimisation was to achieve a precision of better than 0.09 in the Ca/P ratio, in order to be able to distinguish between all healthy and osteoporotic regions. Electron dispersive X-ray spectroscopy (EDX) was used to evaluate the performance of CT-DEA on bone apatite. Ca/P ratio measurements were made on the same healthy and inflammation mediated osteoporotic (IMO) rabbit cortical bone surfaces, using CT-DEA and EDX. The mean di fference in the Ca/P ratio between the two techniques was 0.11± 0.08 (8 6%) and the correlation was R²=0.69, suggesting su cient con dence in the experimental capabilities of the CT-DEA technique. Healthy and IMO rabbit, both collagen-free and intact, cortical bone samples were assessed by CT-DEA. Qualitative analysis of the results involved the production of Ca/P ratio and density distribution maps. Quantitative analysis involved the quanti cation of the Ca/P ratio and density across the whole sample and in volumes of interest, as well as the low Ca/P ratio proportion in each sample. Furthermore, a 3D region growing technique was used to study the uniformity of Ca/P ratio in the samples. Results showed di erences in both density and Ca/P ratio between healthy and IMO bone samples, supporting their use as possible osteoporosis indicators and the use of the developed technique for further studies."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Assessment of the 3D spatial distribution of the Calcium/Phosphorus ratio in bone"]}]}],"canonical_facts":{"dc:creator":["Hadjipanteli, A"],"dc:date":["2013-09-28"],"dc:date.issued":["2013-09"],"dc:description.abstract":["The purpose of this study was the development of a technique for the non-invasive assessment of the 3D spatial distribution of the Ca/P ratio in bone, which can be applied in a conventional computed-tomography (CT) system, to investigate the variation of Ca/P ratio in healthy and osteoporotic bone, and to potentially enhance osteoporosis understanding and diagnosis. Three-material mass-fraction decomposition CT dual energy analysis (CT-DEA) was developed and optimised for the assessment of Ca/P ratio. As part of this process, density values are provided as a bi-product. The technique was optimised and experimentally applied through a microCT system. The target of the optimisation was to achieve a precision of better than 0.09 in the Ca/P ratio, in order to be able to distinguish between all healthy and osteoporotic regions. Electron dispersive X-ray spectroscopy (EDX) was used to evaluate the performance of CT-DEA on bone apatite. Ca/P ratio measurements were made on the same healthy and inflammation mediated osteoporotic (IMO) rabbit cortical bone surfaces, using CT-DEA and EDX. The mean di fference in the Ca/P ratio between the two techniques was 0.11± 0.08 (8 6%) and the correlation was R²=0.69, suggesting su cient con dence in the experimental capabilities of the CT-DEA technique. Healthy and IMO rabbit, both collagen-free and intact, cortical bone samples were assessed by CT-DEA. Qualitative analysis of the results involved the production of Ca/P ratio and density distribution maps. Quantitative analysis involved the quanti cation of the Ca/P ratio and density across the whole sample and in volumes of interest, as well as the low Ca/P ratio proportion in each sample. Furthermore, a 3D region growing technique was used to study the uniformity of Ca/P ratio in the samples. Results showed di erences in both density and Ca/P ratio between healthy and IMO bone samples, supporting their use as possible osteoporosis indicators and the use of the developed technique for further studies."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/1406401/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics and Bioengineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Assessment of the 3D spatial distribution of the Calcium/Phosphorus ratio in bone"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T03:33:55Z"}