{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:1417079"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:1417079","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Automated multi-parameter monitoring of neo-nates","abstract":"Advancements in monitoring technology have led to an increasing amount of physiological data; such as heart rate and oxygen saturation, being accumulated in hospitals. A high rate of false alarms in the neonatal intensive care environment due to inadequate analysis of data highlights the need for an intelligent detection system with improved specificity that provides timely alerts to allow early clinical intervention. Current cot-side monitoring systems analyse data channels independently by applying parameter limits. This simplistic system produces a large proportion of false alerts rendering it futile. Ideally, algorithms should be developed to analyse the data to produce clinically useful information and a model that combines data channels for intelligent analysis is desirable. In this thesis, the typical data channels measured in the neonatal intensive care unit (NICU) and the complications encountered in the NICU are reviewed. Previous work on automated patient monitoring and the various approaches for this project are examined. The model would be required to learn ‘stable’ data and indicate novelty when data patterns deviate significantly from this reference. It needs to handle data with unknown underlying distributions. Three statistical models are compared to evaluate their suitability to extract clinical events from neonatal physiological data. These include kernel density estimation (KDE), kernel principal component analysis (KPCA) and one-class support vector machines (OCSVM). The goal is to reduce the false detection rate without altering the sensitivity that is achieved by the current monitor system. Further work involved improving the model and investigating the effect of incorporating additional parameters derived from the data. Physiological data from cot-side monitors and clinical data relating to patient deterioration were collected from nine premature infants. All three novelty detection models that were developed were able to improve event detection from negligible specificity, provided by current methods, to over 70% whilst maintaining high sensitivity.","abstract_html":"Advancements in monitoring technology have led to an increasing amount of physiological data; such as heart rate and oxygen saturation, being accumulated in hospitals. A high rate of false alarms in the neonatal intensive care environment due to inadequate analysis of data highlights the need for an intelligent detection system with improved specificity that provides timely alerts to allow early clinical intervention. Current cot-side monitoring systems analyse data channels independently by applying parameter limits. This simplistic system produces a large proportion of false alerts rendering it futile. Ideally, algorithms should be developed to analyse the data to produce clinically useful information and a model that combines data channels for intelligent analysis is desirable. In this thesis, the typical data channels measured in the neonatal intensive care unit (NICU) and the complications encountered in the NICU are reviewed. Previous work on automated patient monitoring and the various approaches for this project are examined. The model would be required to learn ‘stable’ data and indicate novelty when data patterns deviate significantly from this reference. It needs to handle data with unknown underlying distributions. Three statistical models are compared to evaluate their suitability to extract clinical events from neonatal physiological data. These include kernel density estimation (KDE), kernel principal component analysis (KPCA) and one-class support vector machines (OCSVM). The goal is to reduce the false detection rate without altering the sensitivity that is achieved by the current monitor system. Further work involved improving the model and investigating the effect of incorporating additional parameters derived from the data. Physiological data from cot-side monitors and clinical data relating to patient deterioration were collected from nine premature infants. All three novelty detection models that were developed were able to improve event detection from negligible specificity, provided by current methods, to over 70% whilst maintaining high sensitivity.","abstract_has_math":false,"creators":["Gangadharan, V"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-12","date_published":"2013-12","updated_at":"2026-11-26T03:34:36Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/1417079/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/1417079/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A1417079","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A1417079","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gangadharan, V"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-12-28"]},{"key":"dc:date.issued","label":"Date","values":["2013-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics and Bioengineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/1417079/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Advancements in monitoring technology have led to an increasing amount of physiological data; such as heart rate and oxygen saturation, being accumulated in hospitals. A high rate of false alarms in the neonatal intensive care environment due to inadequate analysis of data highlights the need for an intelligent detection system with improved specificity that provides timely alerts to allow early clinical intervention. Current cot-side monitoring systems analyse data channels independently by applying parameter limits. This simplistic system produces a large proportion of false alerts rendering it futile. Ideally, algorithms should be developed to analyse the data to produce clinically useful information and a model that combines data channels for intelligent analysis is desirable. In this thesis, the typical data channels measured in the neonatal intensive care unit (NICU) and the complications encountered in the NICU are reviewed. Previous work on automated patient monitoring and the various approaches for this project are examined. The model would be required to learn ‘stable’ data and indicate novelty when data patterns deviate significantly from this reference. It needs to handle data with unknown underlying distributions. Three statistical models are compared to evaluate their suitability to extract clinical events from neonatal physiological data. These include kernel density estimation (KDE), kernel principal component analysis (KPCA) and one-class support vector machines (OCSVM). The goal is to reduce the false detection rate without altering the sensitivity that is achieved by the current monitor system. Further work involved improving the model and investigating the effect of incorporating additional parameters derived from the data. Physiological data from cot-side monitors and clinical data relating to patient deterioration were collected from nine premature infants. All three novelty detection models that were developed were able to improve event detection from negligible specificity, provided by current methods, to over 70% whilst maintaining high sensitivity."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Automated multi-parameter monitoring of neo-nates"]}]}],"canonical_facts":{"dc:creator":["Gangadharan, V"],"dc:date":["2013-12-28"],"dc:date.issued":["2013-12"],"dc:description.abstract":["Advancements in monitoring technology have led to an increasing amount of physiological data; such as heart rate and oxygen saturation, being accumulated in hospitals. A high rate of false alarms in the neonatal intensive care environment due to inadequate analysis of data highlights the need for an intelligent detection system with improved specificity that provides timely alerts to allow early clinical intervention. Current cot-side monitoring systems analyse data channels independently by applying parameter limits. This simplistic system produces a large proportion of false alerts rendering it futile. Ideally, algorithms should be developed to analyse the data to produce clinically useful information and a model that combines data channels for intelligent analysis is desirable. In this thesis, the typical data channels measured in the neonatal intensive care unit (NICU) and the complications encountered in the NICU are reviewed. Previous work on automated patient monitoring and the various approaches for this project are examined. The model would be required to learn ‘stable’ data and indicate novelty when data patterns deviate significantly from this reference. It needs to handle data with unknown underlying distributions. Three statistical models are compared to evaluate their suitability to extract clinical events from neonatal physiological data. These include kernel density estimation (KDE), kernel principal component analysis (KPCA) and one-class support vector machines (OCSVM). The goal is to reduce the false detection rate without altering the sensitivity that is achieved by the current monitor system. Further work involved improving the model and investigating the effect of incorporating additional parameters derived from the data. Physiological data from cot-side monitors and clinical data relating to patient deterioration were collected from nine premature infants. All three novelty detection models that were developed were able to improve event detection from negligible specificity, provided by current methods, to over 70% whilst maintaining high sensitivity."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/1417079/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics and Bioengineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Automated multi-parameter monitoring of neo-nates"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T03:34:36Z"}