{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:1419100"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:1419100","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Development of Preparative Microfluidic Techniques for Lysis of Microbial Cells and Affinity Purification of Proteins","abstract":"In order to fully realise the benefits of microscale mammalian cell culture and microbial fermentation systems, a device capable of online sample preparation to enable further investigation of product quality is a key requirement. The aim of this work is to move toward such a device by designing and characterising a microfluidic lysis device and microaffinity chromatography device that are compatible with each other. The resulting microfluidic lysis device is useful for preparatory lysis of microbial cells. It works by mixing a lysis reagent (BugBuster MastermixTM), with microbial culture, using a T-Piece connection. Lysis takes place in a 700µm internal diameter fused silica capillary. The device was able to successfully lyse microbial cells with similar active Glutathione S Transferase release to sonication. The operating flowrate range of the device was 3.207µL min-1 to 6.414 µL min-1 and the device volume was 30µL - 60µL. The microaffinity chromatography column performed well in studies with pure Glutathione S Transferase. It showed good loading and elution behaviour. The breakthrough and elution curves, and quantity of protein eluted per unit bed volume, were similar to lab scale. The difference being as a result of experimental error. The column also performed well with a 100% clarified Escherichia coli lysate containing recombinant Glutathione S Transferase from Schistosoma japonicum. The eluate had a purity of 55% and concentration of 2.24 mg/ml. The column was fabricated from inexpensive fused silica capillary. It had an internal diameter of 700µm, a length of 5cm (the same length as a typical lab scale Glutathione Affinity column), and a bed volume of approximately 19µL. The operating flowrate range for the column was the same as the microlysis device.","abstract_html":"In order to fully realise the benefits of microscale mammalian cell culture and microbial fermentation systems, a device capable of online sample preparation to enable further investigation of product quality is a key requirement. The aim of this work is to move toward such a device by designing and characterising a microfluidic lysis device and microaffinity chromatography device that are compatible with each other. The resulting microfluidic lysis device is useful for preparatory lysis of microbial cells. It works by mixing a lysis reagent (BugBuster MastermixTM), with microbial culture, using a T-Piece connection. Lysis takes place in a 700µm internal diameter fused silica capillary. The device was able to successfully lyse microbial cells with similar active Glutathione S Transferase release to sonication. The operating flowrate range of the device was 3.207µL min-1 to 6.414 µL min-1 and the device volume was 30µL - 60µL. The microaffinity chromatography column performed well in studies with pure Glutathione S Transferase. It showed good loading and elution behaviour. The breakthrough and elution curves, and quantity of protein eluted per unit bed volume, were similar to lab scale. The difference being as a result of experimental error. The column also performed well with a 100% clarified Escherichia coli lysate containing recombinant Glutathione S Transferase from Schistosoma japonicum. The eluate had a purity of 55% and concentration of 2.24 mg/ml. The column was fabricated from inexpensive fused silica capillary. It had an internal diameter of 700µm, a length of 5cm (the same length as a typical lab scale Glutathione Affinity column), and a bed volume of approximately 19µL. The operating flowrate range for the column was the same as the microlysis device.","abstract_has_math":false,"creators":["El-Sabbahy, H"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-09","date_published":"2013-09","updated_at":"2026-11-26T03:35:14Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/1419100/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/1419100/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A1419100","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A1419100","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["El-Sabbahy, H"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-09-28"]},{"key":"dc:date.issued","label":"Date","values":["2013-09"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Biochemical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/1419100/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In order to fully realise the benefits of microscale mammalian cell culture and microbial fermentation systems, a device capable of online sample preparation to enable further investigation of product quality is a key requirement. The aim of this work is to move toward such a device by designing and characterising a microfluidic lysis device and microaffinity chromatography device that are compatible with each other. The resulting microfluidic lysis device is useful for preparatory lysis of microbial cells. It works by mixing a lysis reagent (BugBuster MastermixTM), with microbial culture, using a T-Piece connection. Lysis takes place in a 700µm internal diameter fused silica capillary. The device was able to successfully lyse microbial cells with similar active Glutathione S Transferase release to sonication. The operating flowrate range of the device was 3.207µL min-1 to 6.414 µL min-1 and the device volume was 30µL - 60µL. The microaffinity chromatography column performed well in studies with pure Glutathione S Transferase. It showed good loading and elution behaviour. The breakthrough and elution curves, and quantity of protein eluted per unit bed volume, were similar to lab scale. The difference being as a result of experimental error. The column also performed well with a 100% clarified Escherichia coli lysate containing recombinant Glutathione S Transferase from Schistosoma japonicum. The eluate had a purity of 55% and concentration of 2.24 mg/ml. The column was fabricated from inexpensive fused silica capillary. It had an internal diameter of 700µm, a length of 5cm (the same length as a typical lab scale Glutathione Affinity column), and a bed volume of approximately 19µL. The operating flowrate range for the column was the same as the microlysis device."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of Preparative Microfluidic Techniques for Lysis of Microbial Cells and Affinity Purification of Proteins"]}]}],"canonical_facts":{"dc:creator":["El-Sabbahy, H"],"dc:date":["2013-09-28"],"dc:date.issued":["2013-09"],"dc:description.abstract":["In order to fully realise the benefits of microscale mammalian cell culture and microbial fermentation systems, a device capable of online sample preparation to enable further investigation of product quality is a key requirement. The aim of this work is to move toward such a device by designing and characterising a microfluidic lysis device and microaffinity chromatography device that are compatible with each other. The resulting microfluidic lysis device is useful for preparatory lysis of microbial cells. It works by mixing a lysis reagent (BugBuster MastermixTM), with microbial culture, using a T-Piece connection. Lysis takes place in a 700µm internal diameter fused silica capillary. The device was able to successfully lyse microbial cells with similar active Glutathione S Transferase release to sonication. The operating flowrate range of the device was 3.207µL min-1 to 6.414 µL min-1 and the device volume was 30µL - 60µL. The microaffinity chromatography column performed well in studies with pure Glutathione S Transferase. It showed good loading and elution behaviour. The breakthrough and elution curves, and quantity of protein eluted per unit bed volume, were similar to lab scale. The difference being as a result of experimental error. The column also performed well with a 100% clarified Escherichia coli lysate containing recombinant Glutathione S Transferase from Schistosoma japonicum. The eluate had a purity of 55% and concentration of 2.24 mg/ml. The column was fabricated from inexpensive fused silica capillary. It had an internal diameter of 700µm, a length of 5cm (the same length as a typical lab scale Glutathione Affinity column), and a bed volume of approximately 19µL. The operating flowrate range for the column was the same as the microlysis device."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/1419100/"],"dc:language":["en","eng"],"dc:publisher.department":["Biochemical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Development of Preparative Microfluidic Techniques for Lysis of Microbial Cells and Affinity Purification of Proteins"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T03:35:14Z"}