{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:1446156"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:1446156","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"In-plane mechanochemistry at model biological interfaces","abstract":"When a chemical or biological reaction occurs on one surface of a microfab- ricated cantilever, a surface stress is generated resulting in cantilever bending motion. This signal transduction mechanism has recently been employed to detect DNA hybridisation and protein recognition, and has attracted much attention as a novel label-free biosensor. However, the biosensing application of cantilevers can best be realised if we develop a fundamental understanding of what causes the cantilever to bend In this thesis, I have performed systematic pH titration experiments using various self-assembled monolayers (SAMs) of alkanethiols HS(CH2) X on gold coated cantilevers, which represent a model organic system by virtue of the relatively well-defined surface chemistry. Differential surface stress measurements were taken to probe the biochemically specific interfacial forces, which were found to critically depend upon multiple factors including pH, ion species, and ionic strength of the aqueous environment, as well as chain length and terminal functional group of SAMs. These findings provide important insights into the fundamental origins of surface stress generation, which have broad implications in the study of biochemical interfaces from molecular thin films to cellular membranes.","abstract_html":"When a chemical or biological reaction occurs on one surface of a microfab- ricated cantilever, a surface stress is generated resulting in cantilever bending motion. This signal transduction mechanism has recently been employed to detect DNA hybridisation and protein recognition, and has attracted much attention as a novel label-free biosensor. However, the biosensing application of cantilevers can best be realised if we develop a fundamental understanding of what causes the cantilever to bend In this thesis, I have performed systematic pH titration experiments using various self-assembled monolayers (SAMs) of alkanethiols HS(CH2) X on gold coated cantilevers, which represent a model organic system by virtue of the relatively well-defined surface chemistry. Differential surface stress measurements were taken to probe the biochemically specific interfacial forces, which were found to critically depend upon multiple factors including pH, ion species, and ionic strength of the aqueous environment, as well as chain length and terminal functional group of SAMs. These findings provide important insights into the fundamental origins of surface stress generation, which have broad implications in the study of biochemical interfaces from molecular thin films to cellular membranes.","abstract_has_math":false,"creators":["Watari, M"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-12","date_published":"2007-12","updated_at":"2026-11-26T04:20:18Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/1446156/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/1446156/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A1446156","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A1446156","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Watari, M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007-12-31"]},{"key":"dc:date.issued","label":"Date","values":["2007-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Medicine"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/1446156/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["When a chemical or biological reaction occurs on one surface of a microfab- ricated cantilever, a surface stress is generated resulting in cantilever bending motion. This signal transduction mechanism has recently been employed to detect DNA hybridisation and protein recognition, and has attracted much attention as a novel label-free biosensor. However, the biosensing application of cantilevers can best be realised if we develop a fundamental understanding of what causes the cantilever to bend In this thesis, I have performed systematic pH titration experiments using various self-assembled monolayers (SAMs) of alkanethiols HS(CH2) X on gold coated cantilevers, which represent a model organic system by virtue of the relatively well-defined surface chemistry. Differential surface stress measurements were taken to probe the biochemically specific interfacial forces, which were found to critically depend upon multiple factors including pH, ion species, and ionic strength of the aqueous environment, as well as chain length and terminal functional group of SAMs. These findings provide important insights into the fundamental origins of surface stress generation, which have broad implications in the study of biochemical interfaces from molecular thin films to cellular membranes."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["In-plane mechanochemistry at model biological interfaces"]}]}],"canonical_facts":{"dc:creator":["Watari, M"],"dc:date":["2007-12-31"],"dc:date.issued":["2007-12"],"dc:description.abstract":["When a chemical or biological reaction occurs on one surface of a microfab- ricated cantilever, a surface stress is generated resulting in cantilever bending motion. This signal transduction mechanism has recently been employed to detect DNA hybridisation and protein recognition, and has attracted much attention as a novel label-free biosensor. However, the biosensing application of cantilevers can best be realised if we develop a fundamental understanding of what causes the cantilever to bend In this thesis, I have performed systematic pH titration experiments using various self-assembled monolayers (SAMs) of alkanethiols HS(CH2) X on gold coated cantilevers, which represent a model organic system by virtue of the relatively well-defined surface chemistry. Differential surface stress measurements were taken to probe the biochemically specific interfacial forces, which were found to critically depend upon multiple factors including pH, ion species, and ionic strength of the aqueous environment, as well as chain length and terminal functional group of SAMs. These findings provide important insights into the fundamental origins of surface stress generation, which have broad implications in the study of biochemical interfaces from molecular thin films to cellular membranes."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/1446156/"],"dc:language":["en","eng"],"dc:publisher.department":["Department of Medicine"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["In-plane mechanochemistry at model biological interfaces"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T04:20:18Z"}