{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:1446818"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:1446818","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Characterisation and design of ultrasound agent particles","abstract":"Ultrasound contrast agents, consisting of gas bubbles coated with a surfactant or polymer shell, offer benefits in a range of diagnostic and therapeutic applications. However, their behaviour both in vitro and in vivo is by no means fully understood and there remains considerable scope for increasing their effectiveness. The aim of the work described in this thesis is to improve the characterisation of existing contrast agents and to determine how future agents might be designed in order to optimise their performance. Previous theoretical and experimental work relating to both contrast agents and free gas bubbles will be reviewed. This will be followed by an assessment of the validity of the assumptions underlying existing models for contrast agents. In particular, examination will be made of: the modelling of the material coating the contrast agent particles (CAPs), the influence of blood cells upon CAP dynamics and multiple scattering of ultrasound in CAP suspensions. The results from a combination of computer simulations and experimental testing will be used to derive a new, generalised model for CAP behaviour. The model will be used to carry out a sensitivity analysis in order to identify the most significant factors controlling CAP behaviour. Based on these findings, a number of new designs will be developed, with the aim of enhancing CAP detectability at low insonation pressures. The designs will be evaluated in terms of their performance, based on the results of experiments using scale models. Finally, an assessment of the areas for future work will be made.","abstract_html":"Ultrasound contrast agents, consisting of gas bubbles coated with a surfactant or polymer shell, offer benefits in a range of diagnostic and therapeutic applications. However, their behaviour both in vitro and in vivo is by no means fully understood and there remains considerable scope for increasing their effectiveness. The aim of the work described in this thesis is to improve the characterisation of existing contrast agents and to determine how future agents might be designed in order to optimise their performance. Previous theoretical and experimental work relating to both contrast agents and free gas bubbles will be reviewed. This will be followed by an assessment of the validity of the assumptions underlying existing models for contrast agents. In particular, examination will be made of: the modelling of the material coating the contrast agent particles (CAPs), the influence of blood cells upon CAP dynamics and multiple scattering of ultrasound in CAP suspensions. The results from a combination of computer simulations and experimental testing will be used to derive a new, generalised model for CAP behaviour. The model will be used to carry out a sensitivity analysis in order to identify the most significant factors controlling CAP behaviour. Based on these findings, a number of new designs will be developed, with the aim of enhancing CAP detectability at low insonation pressures. The designs will be evaluated in terms of their performance, based on the results of experiments using scale models. Finally, an assessment of the areas for future work will be made.","abstract_has_math":false,"creators":["Stride, Eleanor Phoebe Jane"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-04","date_published":"2005-04","updated_at":"2026-11-26T04:23:50Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/1446818/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/1446818/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A1446818","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A1446818","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Stride, Eleanor Phoebe Jane"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-04-30"]},{"key":"dc:date.issued","label":"Date","values":["2005-04"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Mechanical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/1446818/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ultrasound contrast agents, consisting of gas bubbles coated with a surfactant or polymer shell, offer benefits in a range of diagnostic and therapeutic applications. However, their behaviour both in vitro and in vivo is by no means fully understood and there remains considerable scope for increasing their effectiveness. The aim of the work described in this thesis is to improve the characterisation of existing contrast agents and to determine how future agents might be designed in order to optimise their performance. Previous theoretical and experimental work relating to both contrast agents and free gas bubbles will be reviewed. This will be followed by an assessment of the validity of the assumptions underlying existing models for contrast agents. In particular, examination will be made of: the modelling of the material coating the contrast agent particles (CAPs), the influence of blood cells upon CAP dynamics and multiple scattering of ultrasound in CAP suspensions. The results from a combination of computer simulations and experimental testing will be used to derive a new, generalised model for CAP behaviour. The model will be used to carry out a sensitivity analysis in order to identify the most significant factors controlling CAP behaviour. Based on these findings, a number of new designs will be developed, with the aim of enhancing CAP detectability at low insonation pressures. The designs will be evaluated in terms of their performance, based on the results of experiments using scale models. Finally, an assessment of the areas for future work will be made."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Characterisation and design of ultrasound agent particles"]}]}],"canonical_facts":{"dc:creator":["Stride, Eleanor Phoebe Jane"],"dc:date":["2005-04-30"],"dc:date.issued":["2005-04"],"dc:description.abstract":["Ultrasound contrast agents, consisting of gas bubbles coated with a surfactant or polymer shell, offer benefits in a range of diagnostic and therapeutic applications. However, their behaviour both in vitro and in vivo is by no means fully understood and there remains considerable scope for increasing their effectiveness. The aim of the work described in this thesis is to improve the characterisation of existing contrast agents and to determine how future agents might be designed in order to optimise their performance. Previous theoretical and experimental work relating to both contrast agents and free gas bubbles will be reviewed. This will be followed by an assessment of the validity of the assumptions underlying existing models for contrast agents. In particular, examination will be made of: the modelling of the material coating the contrast agent particles (CAPs), the influence of blood cells upon CAP dynamics and multiple scattering of ultrasound in CAP suspensions. The results from a combination of computer simulations and experimental testing will be used to derive a new, generalised model for CAP behaviour. The model will be used to carry out a sensitivity analysis in order to identify the most significant factors controlling CAP behaviour. Based on these findings, a number of new designs will be developed, with the aim of enhancing CAP detectability at low insonation pressures. The designs will be evaluated in terms of their performance, based on the results of experiments using scale models. Finally, an assessment of the areas for future work will be made."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/1446818/"],"dc:language":["en","eng"],"dc:publisher.department":["Department of Mechanical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Characterisation and design of ultrasound agent particles"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T04:23:50Z"}