{"id":{"repo_id":"ukzn","oai_identifier":"oai:researchspace.ukzn.ac.za:10413/12121"},"canonical_url":"https://search.ndltd.org/etd/ukzn/oai:researchspace.ukzn.ac.za:10413/12121","repository":{"repo_id":"ukzn","name":"University of Kwazulu-Natal","base_url":"https://researchspace.ukzn.ac.za/server/oai/request"},"display":{"title":"An investigation of electric-field-gradient-induced Birefringence in fluids.","abstract":"The theory of electric-field-gradient-induced birefringence (EFGIB, the Buckingham effect) is briefly reviewed, and modifications to the Buckingham-effect apparatus are described. These modifications have increased the throughput of the light reaching the photodiode detector, thereby considerably enhancing the sensitivity of the measurements. In addition, a new PID voltage controller has been built for the high-voltage power amplifier, ensuring stability to better than 0.1% over long periods of time. Room-temperature measurements of the Buckingham effect for gaseous oxygen have been undertaken, allowing for an estimation of the traceless electric quadrupole moment £ of O2. The quadrupole moment has been extracted from the measured data by making the assumption that the temperature-independent hyperpolarizability contribution to the EFGIB is negligible. The limitations of this assumption are discussed. The value obtained for the electric quadrupole moment of O2 is £ = (¡1.033 § 0.027) £ 10¡40 Cm2. The available ab initio quantum-computed values of£found forO2 in the literature are tabulated, and are comparedwith our measured value. Potential future work, where a full temperature-dependent study of the EFGIB of O2 is envisioned, is briefly described.","abstract_html":"The theory of electric-field-gradient-induced birefringence (EFGIB, the Buckingham effect) is briefly reviewed, and modifications to the Buckingham-effect apparatus are described. These modifications have increased the throughput of the light reaching the photodiode detector, thereby considerably enhancing the sensitivity of the measurements. In addition, a new PID voltage controller has been built for the high-voltage power amplifier, ensuring stability to better than 0.1% over long periods of time. Room-temperature measurements of the Buckingham effect for gaseous oxygen have been undertaken, allowing for an estimation of the traceless electric quadrupole moment £ of O2. The quadrupole moment has been extracted from the measured data by making the assumption that the temperature-independent hyperpolarizability contribution to the EFGIB is negligible. The limitations of this assumption are discussed. The value obtained for the electric quadrupole moment of O2 is £ = (¡1.033 § 0.027) £ 10¡40 Cm2. The available ab initio quantum-computed values of£found forO2 in the literature are tabulated, and are comparedwith our measured value. Potential future work, where a full temperature-dependent study of the EFGIB of O2 is envisioned, is briefly described.","abstract_has_math":false,"creators":["Ntombela, Siyabonga Sibusiso."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Couling, Vincent William."],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-27T00:31:22Z","subjects":["Refraction, Double.","Electric fields.","Theses -- Physics."],"languages":["en_ZA"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10413/12121","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10413/12121","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aukzn%3Aoai%3Aresearchspace.ukzn.ac.za%3A10413%2F12121","prefix":"oai_dc"},"source_record":{"url":"https://researchspace.ukzn.ac.za/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aresearchspace.ukzn.ac.za%3A10413%2F12121","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Couling, Vincent William."]},{"key":"dc:creator","label":"Author","values":["Ntombela, Siyabonga Sibusiso."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-06-17T16:37:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-06-17T16:37:58Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Refraction, Double.","Electric fields.","Theses -- Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_ZA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10413/12121"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["M. Sc. University of KwaZulu-Natal, Pietermaritzburg 2014."]},{"key":"dc:description.abstract","label":"Abstract","values":["The theory of electric-field-gradient-induced birefringence (EFGIB, the Buckingham effect) is briefly reviewed, and modifications to the Buckingham-effect apparatus are described. These modifications have increased the throughput of the light reaching the photodiode detector, thereby considerably enhancing the sensitivity of the measurements. In addition, a new PID voltage controller has been built for the high-voltage power amplifier, ensuring stability to better than 0.1% over long periods of time. Room-temperature measurements of the Buckingham effect for gaseous oxygen have been undertaken, allowing for an estimation of the traceless electric quadrupole moment £ of O2. The quadrupole moment has been extracted from the measured data by making the assumption that the temperature-independent hyperpolarizability contribution to the EFGIB is negligible. The limitations of this assumption are discussed. The value obtained for the electric quadrupole moment of O2 is £ = (¡1.033 § 0.027) £ 10¡40 Cm2. The available ab initio quantum-computed values of£found forO2 in the literature are tabulated, and are comparedwith our measured value. Potential future work, where a full temperature-dependent study of the EFGIB of O2 is envisioned, is briefly described."]},{"key":"dc:title","label":"Title","values":["An investigation of electric-field-gradient-induced Birefringence in fluids."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Couling, Vincent William."],"dc:creator":["Ntombela, Siyabonga Sibusiso."],"dc:date.accessioned":["2015-06-17T16:37:58Z"],"dc:date.available":["2015-06-17T16:37:58Z"],"dc:date.created":["2014"],"dc:date.issued":["2014"],"dc:description":["M. Sc. University of KwaZulu-Natal, Pietermaritzburg 2014."],"dc:description.abstract":["The theory of electric-field-gradient-induced birefringence (EFGIB, the Buckingham effect) is briefly reviewed, and modifications to the Buckingham-effect apparatus are described. These modifications have increased the throughput of the light reaching the photodiode detector, thereby considerably enhancing the sensitivity of the measurements. In addition, a new PID voltage controller has been built for the high-voltage power amplifier, ensuring stability to better than 0.1% over long periods of time. Room-temperature measurements of the Buckingham effect for gaseous oxygen have been undertaken, allowing for an estimation of the traceless electric quadrupole moment £ of O2. The quadrupole moment has been extracted from the measured data by making the assumption that the temperature-independent hyperpolarizability contribution to the EFGIB is negligible. The limitations of this assumption are discussed. The value obtained for the electric quadrupole moment of O2 is £ = (¡1.033 § 0.027) £ 10¡40 Cm2. The available ab initio quantum-computed values of£found forO2 in the literature are tabulated, and are comparedwith our measured value. Potential future work, where a full temperature-dependent study of the EFGIB of O2 is envisioned, is briefly described."],"dc:identifier.uri":["http://hdl.handle.net/10413/12121"],"dc:language.iso":["en_ZA"],"dc:subject":["Refraction, Double.","Electric fields.","Theses -- Physics."],"dc:title":["An investigation of electric-field-gradient-induced Birefringence in fluids."],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-27T00:31:22Z"}