{"id":{"repo_id":"ukzn","oai_identifier":"oai:researchspace.ukzn.ac.za:10413/14149"},"canonical_url":"https://search.ndltd.org/etd/ukzn/oai:researchspace.ukzn.ac.za:10413/14149","repository":{"repo_id":"ukzn","name":"University of Kwazulu-Natal","base_url":"https://researchspace.ukzn.ac.za/server/oai/request"},"display":{"title":"Microfluidic technologies for capturing and concentrating human immunodeficiency virus-1 (HIV-1) particles.","abstract":"HIV-1 RNA assays are routinely used in developed countries to monitor the effectiveness of antiretroviral therapy (ART). These assays require well-trained operators, expensive equipment and reagents, and established laboratory infrastructure. These requirements limit their usefulness in resource-limited settings where people are most afflicted by the HIV-1 epidemic. Recent advances in microfluidics and nanotechnology offer new approaches for rapid, low-cost, robust and simple HIV-1 viral load monitoring systems. Here we describe an approach within a microfluidic device to directly detect HIV-1 virus particles using an immune sandwich assay that includes anti-gp120 antibodies -conjugated to polystyrene microspheres and fluorescently labelled goat anti-HIV-1 FITC detection antibodies. The anti-gp120 antibody-conjugated microspheres were employed to capture and concentrate HIV-1 particles, whereas the FITC detection antibodies were used to generate fluorescent signal that represented the number of captured viruses. In the presence of HIV-1 particles, addition of microspheres and FITC detection antibody led to the formation of a microsphere/HIV-1 particle/FITC detection antibody complex. This complex was measured by analysing the fluorescence intensity produced by the FITC detection antibody bound to the HIV-1 particle within the complex. We demonstrated the utility of an in-house microfluidic device and assay in detecting 1x106 virus particles/μl with a significance of (p≤0.01). This assay was completed within 3.8 hours, without any pre- or post- treatment of reagents.","abstract_html":"HIV-1 RNA assays are routinely used in developed countries to monitor the effectiveness of antiretroviral therapy (ART). These assays require well-trained operators, expensive equipment and reagents, and established laboratory infrastructure. These requirements limit their usefulness in resource-limited settings where people are most afflicted by the HIV-1 epidemic. Recent advances in microfluidics and nanotechnology offer new approaches for rapid, low-cost, robust and simple HIV-1 viral load monitoring systems. Here we describe an approach within a microfluidic device to directly detect HIV-1 virus particles using an immune sandwich assay that includes anti-gp120 antibodies -conjugated to polystyrene microspheres and fluorescently labelled goat anti-HIV-1 FITC detection antibodies. The anti-gp120 antibody-conjugated microspheres were employed to capture and concentrate HIV-1 particles, whereas the FITC detection antibodies were used to generate fluorescent signal that represented the number of captured viruses. In the presence of HIV-1 particles, addition of microspheres and FITC detection antibody led to the formation of a microsphere/HIV-1 particle/FITC detection antibody complex. This complex was measured by analysing the fluorescence intensity produced by the FITC detection antibody bound to the HIV-1 particle within the complex. We demonstrated the utility of an in-house microfluidic device and assay in detecting 1x106 virus particles/μl with a significance of (p≤0.01). This assay was completed within 3.8 hours, without any pre- or post- treatment of reagents.","abstract_has_math":false,"creators":["McArthur, Chanelle Crystal."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Balagaddé, Frederick."],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-26T23:08:00Z","subjects":["Microfluidics.","Immunodeficiency.","HIV (Viruses)","Theses -- Medical microbiology."],"languages":["en_ZA"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10413/14149","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10413/14149","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aukzn%3Aoai%3Aresearchspace.ukzn.ac.za%3A10413%2F14149","prefix":"oai_dc"},"source_record":{"url":"https://researchspace.ukzn.ac.za/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aresearchspace.ukzn.ac.za%3A10413%2F14149","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Balagaddé, Frederick."]},{"key":"dc:creator","label":"Author","values":["McArthur, Chanelle Crystal."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-02-27T08:01:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-02-27T08:01:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidics.","Immunodeficiency.","HIV (Viruses)","Theses -- Medical microbiology."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_ZA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10413/14149"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Medical Sciences in Medical Microbiology. University of KwaZulu-Natal, Medical school 2016."]},{"key":"dc:description.abstract","label":"Abstract","values":["HIV-1 RNA assays are routinely used in developed countries to monitor the effectiveness of antiretroviral therapy (ART). These assays require well-trained operators, expensive equipment and reagents, and established laboratory infrastructure. These requirements limit their usefulness in resource-limited settings where people are most afflicted by the HIV-1 epidemic. Recent advances in microfluidics and nanotechnology offer new approaches for rapid, low-cost, robust and simple HIV-1 viral load monitoring systems. Here we describe an approach within a microfluidic device to directly detect HIV-1 virus particles using an immune sandwich assay that includes anti-gp120 antibodies -conjugated to polystyrene microspheres and fluorescently labelled goat anti-HIV-1 FITC detection antibodies. The anti-gp120 antibody-conjugated microspheres were employed to capture and concentrate HIV-1 particles, whereas the FITC detection antibodies were used to generate fluorescent signal that represented the number of captured viruses. In the presence of HIV-1 particles, addition of microspheres and FITC detection antibody led to the formation of a microsphere/HIV-1 particle/FITC detection antibody complex. This complex was measured by analysing the fluorescence intensity produced by the FITC detection antibody bound to the HIV-1 particle within the complex. We demonstrated the utility of an in-house microfluidic device and assay in detecting 1x106 virus particles/μl with a significance of (p≤0.01). This assay was completed within 3.8 hours, without any pre- or post- treatment of reagents."]},{"key":"dc:title","label":"Title","values":["Microfluidic technologies for capturing and concentrating human immunodeficiency virus-1 (HIV-1) particles."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Balagaddé, Frederick."],"dc:creator":["McArthur, Chanelle Crystal."],"dc:date.accessioned":["2017-02-27T08:01:00Z"],"dc:date.available":["2017-02-27T08:01:00Z"],"dc:date.created":["2016"],"dc:date.issued":["2016"],"dc:description":["Master of Medical Sciences in Medical Microbiology. University of KwaZulu-Natal, Medical school 2016."],"dc:description.abstract":["HIV-1 RNA assays are routinely used in developed countries to monitor the effectiveness of antiretroviral therapy (ART). These assays require well-trained operators, expensive equipment and reagents, and established laboratory infrastructure. These requirements limit their usefulness in resource-limited settings where people are most afflicted by the HIV-1 epidemic. Recent advances in microfluidics and nanotechnology offer new approaches for rapid, low-cost, robust and simple HIV-1 viral load monitoring systems. Here we describe an approach within a microfluidic device to directly detect HIV-1 virus particles using an immune sandwich assay that includes anti-gp120 antibodies -conjugated to polystyrene microspheres and fluorescently labelled goat anti-HIV-1 FITC detection antibodies. The anti-gp120 antibody-conjugated microspheres were employed to capture and concentrate HIV-1 particles, whereas the FITC detection antibodies were used to generate fluorescent signal that represented the number of captured viruses. In the presence of HIV-1 particles, addition of microspheres and FITC detection antibody led to the formation of a microsphere/HIV-1 particle/FITC detection antibody complex. This complex was measured by analysing the fluorescence intensity produced by the FITC detection antibody bound to the HIV-1 particle within the complex. We demonstrated the utility of an in-house microfluidic device and assay in detecting 1x106 virus particles/μl with a significance of (p≤0.01). This assay was completed within 3.8 hours, without any pre- or post- treatment of reagents."],"dc:identifier.uri":["http://hdl.handle.net/10413/14149"],"dc:language.iso":["en_ZA"],"dc:subject":["Microfluidics.","Immunodeficiency.","HIV (Viruses)","Theses -- Medical microbiology."],"dc:title":["Microfluidic technologies for capturing and concentrating human immunodeficiency virus-1 (HIV-1) particles."],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-26T23:08:00Z"}