{"id":{"repo_id":"umkc","oai_identifier":"oai:mospace.umsystem.edu:10355/12304"},"canonical_url":"https://search.ndltd.org/etd/umkc/oai:mospace.umsystem.edu:10355/12304","repository":{"repo_id":"umkc","name":"University of Missouri - Kansas City","base_url":"https://mospace.umsystem.edu/oai/request"},"display":{"title":"In-situ radio frequency identification (RFID) moisture meter","abstract":"An in-situ moisture meter, utilizing a Radio Frequency Identification (RFID) to detect hidden moisture in walls is studied. Both commercial and household building moisture problems call for a better way to measure moisture within the building envelope. The presence of moisture within the insulating material of the building walls can attribute to the possibility of mold growth. Simple resistor divider type moisture meters are easily realizable but do not always provide the best methodology for detecting moisture levels accurately. An embeddable and unobtrusive means to detect moisture within the wall cavity is studied. The methodology used for detection is an improved type of resistive probe utilizing an integrating amplifier to determine moisture content in typical celluose insulation. To compliment the resistive measurement, a humidity sensor has been added along with a built-in temperature sensor embedded in the MSP430 microcontroller.","abstract_html":"An in-situ moisture meter, utilizing a Radio Frequency Identification (RFID) to detect hidden moisture in walls is studied. Both commercial and household building moisture problems call for a better way to measure moisture within the building envelope. The presence of moisture within the insulating material of the building walls can attribute to the possibility of mold growth. Simple resistor divider type moisture meters are easily realizable but do not always provide the best methodology for detecting moisture levels accurately. An embeddable and unobtrusive means to detect moisture within the wall cavity is studied. The methodology used for detection is an improved type of resistive probe utilizing an integrating amplifier to determine moisture content in typical celluose insulation. To compliment the resistive measurement, a humidity sensor has been added along with a built-in temperature sensor embedded in the MSP430 microcontroller.","abstract_has_math":false,"creators":["Swafford, Brian J."],"institution":"University of Missouri--Kansas City","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Electrical Engineering (UMKC)","degree_department":null,"school":null,"contributors":[],"advisors":["León-Salas, Walter D. (Walter Daniel)"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"12/15/2011","date_published":"12/15/2011","updated_at":"2026-11-19T08:44:13Z","subjects":["Thesis -- University of Missouri--Kansas City -- Engineering","Moisture meters","Radio frequency identification systems"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10355/12304","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10355/12304","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumkc%3Aoai%3Amospace.umsystem.edu%3A10355%2F12304","prefix":"oai_dc"},"source_record":{"url":"https://mospace.umsystem.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amospace.umsystem.edu%3A10355%2F12304","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["León-Salas, Walter D. (Walter Daniel)"]},{"key":"dc:creator","label":"Author","values":["Swafford, Brian J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-12-15T14:42:16Z","2025-12-19T13:48:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-12-15T14:42:16Z","2025-12-19T13:48:18Z"]},{"key":"dc:date.issued","label":"Date","values":["12/15/2011"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2011 Fall"]},{"key":"dc:publisher","label":"Institution","values":["University of Missouri--Kansas City"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering (UMKC)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Missouri--Kansas City"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Moisture meters","Radio frequency identification systems"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Thesis -- University of Missouri--Kansas City -- Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10355/12304"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Title from PDF of title page, viewed on December 15, 2011","Thesis advisor: Walter Daniel León-Salas","Vita","Includes bibliographic references (p. 61-62)","Thesis (M.A.)--School of Computing and Engineering. University of Missouri--Kansas City, 2011"]},{"key":"dc:description.abstract","label":"Abstract","values":["An in-situ moisture meter, utilizing a Radio Frequency Identification (RFID) to detect hidden moisture in walls is studied. Both commercial and household building moisture problems call for a better way to measure moisture within the building envelope. The presence of moisture within the insulating material of the building walls can attribute to the possibility of mold growth. Simple resistor divider type moisture meters are easily realizable but do not always provide the best methodology for detecting moisture levels accurately. An embeddable and unobtrusive means to detect moisture within the wall cavity is studied. The methodology used for detection is an improved type of resistive probe utilizing an integrating amplifier to determine moisture content in typical celluose insulation. To compliment the resistive measurement, a humidity sensor has been added along with a built-in temperature sensor embedded in the MSP430 microcontroller."]},{"key":"dc:description.tableofcontents","label":"Dc Description Tableofcontents","values":["Introduction -- Mold and moisture -- Moisture circuits -- Integrator moisture meter -- Experiment -- Conclusion -- Appendix A. Moisture meter schematic -- Appendix B. Microcontroller program -- Appendix C. Costs -- Appendix D. Power consumption"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["x, 63 pages"]},{"key":"dc:title","label":"Title","values":["In-situ radio frequency identification (RFID) moisture meter"]}]}],"canonical_facts":{"dc:contributor.advisor":["León-Salas, Walter D. (Walter Daniel)"],"dc:creator":["Swafford, Brian J."],"dc:date.accessioned":["2011-12-15T14:42:16Z","2025-12-19T13:48:18Z"],"dc:date.available":["2011-12-15T14:42:16Z","2025-12-19T13:48:18Z"],"dc:date.issued":["12/15/2011"],"dc:date.submitted":["2011 Fall"],"dc:description":["Title from PDF of title page, viewed on December 15, 2011","Thesis advisor: Walter Daniel León-Salas","Vita","Includes bibliographic references (p. 61-62)","Thesis (M.A.)--School of Computing and Engineering. University of Missouri--Kansas City, 2011"],"dc:description.abstract":["An in-situ moisture meter, utilizing a Radio Frequency Identification (RFID) to detect hidden moisture in walls is studied. Both commercial and household building moisture problems call for a better way to measure moisture within the building envelope. The presence of moisture within the insulating material of the building walls can attribute to the possibility of mold growth. Simple resistor divider type moisture meters are easily realizable but do not always provide the best methodology for detecting moisture levels accurately. An embeddable and unobtrusive means to detect moisture within the wall cavity is studied. The methodology used for detection is an improved type of resistive probe utilizing an integrating amplifier to determine moisture content in typical celluose insulation. To compliment the resistive measurement, a humidity sensor has been added along with a built-in temperature sensor embedded in the MSP430 microcontroller."],"dc:description.tableofcontents":["Introduction -- Mold and moisture -- Moisture circuits -- Integrator moisture meter -- Experiment -- Conclusion -- Appendix A. Moisture meter schematic -- Appendix B. Microcontroller program -- Appendix C. Costs -- Appendix D. Power consumption"],"dc:format.extent":["x, 63 pages"],"dc:identifier.uri":["https://hdl.handle.net/10355/12304"],"dc:language.iso":["en_US"],"dc:publisher":["University of Missouri--Kansas City"],"dc:subject.lcsh":["Moisture meters","Radio frequency identification systems"],"dc:subject.other":["Thesis -- University of Missouri--Kansas City -- Engineering"],"dc:title":["In-situ radio frequency identification (RFID) moisture meter"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical Engineering (UMKC)"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Missouri--Kansas City"]},"updated_at":"2026-11-19T08:44:13Z"}