{"id":{"repo_id":"umkc","oai_identifier":"oai:mospace.umsystem.edu:10355/14728"},"canonical_url":"https://search.ndltd.org/etd/umkc/oai:mospace.umsystem.edu:10355/14728","repository":{"repo_id":"umkc","name":"University of Missouri - Kansas City","base_url":"https://mospace.umsystem.edu/oai/request"},"display":{"title":"Detection of diesel leakage from underground storage tank using time domain reflectometry","abstract":"The Environmental Protection Agency (EPA) has established regulations concerning the construction and maintenance of an underground storage tank (UST) system. These regulations also define the means and methods required to detect potential leaks. Leak detection methods defined as â€œother methodsâ€� can be used if specific requirements are achieved. We find in our study time domain reflectometry (TDR) can be used to detect leaks from an UST. The magnitudes of reflections measured by the TDR technique are used to calculate electrical properties of the soil. We find the introduction of diesel fuel, a light nonaqueous phase liquid (LNAPL), into the soil alters the physical and chemical properties of the soil and subsequently the electrical properties. We demonstrate the measured variance of electrical properties can be correlated to the changes of diesel fuel concentration. We find diesel fuel can be detected and changes of concentration can be measured using TDR.","abstract_html":"The Environmental Protection Agency (EPA) has established regulations concerning the construction and maintenance of an underground storage tank (UST) system. These regulations also define the means and methods required to detect potential leaks. Leak detection methods defined as â€œother methodsâ€� can be used if specific requirements are achieved. We find in our study time domain reflectometry (TDR) can be used to detect leaks from an UST. The magnitudes of reflections measured by the TDR technique are used to calculate electrical properties of the soil. We find the introduction of diesel fuel, a light nonaqueous phase liquid (LNAPL), into the soil alters the physical and chemical properties of the soil and subsequently the electrical properties. We demonstrate the measured variance of electrical properties can be correlated to the changes of diesel fuel concentration. We find diesel fuel can be detected and changes of concentration can be measured using TDR.","abstract_has_math":false,"creators":["Barnett, Daniel A."],"institution":"University of Missouri--Kansas City","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Geosciences (UMKC)","degree_department":null,"school":null,"contributors":[],"advisors":["Lee, Jejung"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06-22","date_published":"2012-06-22","updated_at":"2026-11-19T08:45:47Z","subjects":["Thesis -- University of Missouri--Kansas City -- Geosciences","Time-domain reflectometry","Underground storage tanks -- Environmental aspects"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10355/14728","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10355/14728","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumkc%3Aoai%3Amospace.umsystem.edu%3A10355%2F14728","prefix":"oai_dc"},"source_record":{"url":"https://mospace.umsystem.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amospace.umsystem.edu%3A10355%2F14728","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lee, Jejung"]},{"key":"dc:creator","label":"Author","values":["Barnett, Daniel A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-06-22T14:58:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-06-22T14:58:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-06-22"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012 Spring"]},{"key":"dc:publisher","label":"Institution","values":["University of Missouri--Kansas City"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Geosciences (UMKC)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Missouri--Kansas City"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Time-domain reflectometry","Underground storage tanks -- Environmental aspects"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Thesis -- University of Missouri--Kansas City -- Geosciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10355/14728"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Title from PDF of title page, viewed on June 22, 2012","Thesis advisor: Jejung Lee","Vita","Includes bibliographic references (p. 39-40)","Thesis (M.S.)--Dept. of Geosciences. University of Missouri--Kansas City, 2012"]},{"key":"dc:description.abstract","label":"Abstract","values":["The Environmental Protection Agency (EPA) has established regulations concerning the construction and maintenance of an underground storage tank (UST) system. These regulations also define the means and methods required to detect potential leaks. Leak detection methods defined as â€œother methodsâ€� can be used if specific requirements are achieved. We find in our study time domain reflectometry (TDR) can be used to detect leaks from an UST. The magnitudes of reflections measured by the TDR technique are used to calculate electrical properties of the soil. We find the introduction of diesel fuel, a light nonaqueous phase liquid (LNAPL), into the soil alters the physical and chemical properties of the soil and subsequently the electrical properties. We demonstrate the measured variance of electrical properties can be correlated to the changes of diesel fuel concentration. We find diesel fuel can be detected and changes of concentration can be measured using TDR."]},{"key":"dc:description.tableofcontents","label":"Dc Description Tableofcontents","values":["Introduction -- Literature review -- Methodology -- Results and discussion -- Conclusions"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vii, 41 pages"]},{"key":"dc:title","label":"Title","values":["Detection of diesel leakage from underground storage tank using time domain reflectometry"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lee, Jejung"],"dc:creator":["Barnett, Daniel A."],"dc:date.accessioned":["2012-06-22T14:58:05Z"],"dc:date.available":["2012-06-22T14:58:05Z"],"dc:date.issued":["2012-06-22"],"dc:date.submitted":["2012 Spring"],"dc:description":["Title from PDF of title page, viewed on June 22, 2012","Thesis advisor: Jejung Lee","Vita","Includes bibliographic references (p. 39-40)","Thesis (M.S.)--Dept. of Geosciences. University of Missouri--Kansas City, 2012"],"dc:description.abstract":["The Environmental Protection Agency (EPA) has established regulations concerning the construction and maintenance of an underground storage tank (UST) system. These regulations also define the means and methods required to detect potential leaks. Leak detection methods defined as â€œother methodsâ€� can be used if specific requirements are achieved. We find in our study time domain reflectometry (TDR) can be used to detect leaks from an UST. The magnitudes of reflections measured by the TDR technique are used to calculate electrical properties of the soil. We find the introduction of diesel fuel, a light nonaqueous phase liquid (LNAPL), into the soil alters the physical and chemical properties of the soil and subsequently the electrical properties. We demonstrate the measured variance of electrical properties can be correlated to the changes of diesel fuel concentration. We find diesel fuel can be detected and changes of concentration can be measured using TDR."],"dc:description.tableofcontents":["Introduction -- Literature review -- Methodology -- Results and discussion -- Conclusions"],"dc:format.extent":["vii, 41 pages"],"dc:identifier.uri":["http://hdl.handle.net/10355/14728"],"dc:language.iso":["en_US"],"dc:publisher":["University of Missouri--Kansas City"],"dc:subject.lcsh":["Time-domain reflectometry","Underground storage tanks -- Environmental aspects"],"dc:subject.other":["Thesis -- University of Missouri--Kansas City -- Geosciences"],"dc:title":["Detection of diesel leakage from underground storage tank using time domain reflectometry"],"dc:type":["Thesis"],"thesis:degree_discipline":["Geosciences (UMKC)"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Missouri--Kansas City"]},"updated_at":"2026-11-19T08:45:47Z"}