{"id":{"repo_id":"umkc","oai_identifier":"oai:mospace.umsystem.edu:10355/46545"},"canonical_url":"https://search.ndltd.org/etd/umkc/oai:mospace.umsystem.edu:10355/46545","repository":{"repo_id":"umkc","name":"University of Missouri - Kansas City","base_url":"https://mospace.umsystem.edu/oai/request"},"display":{"title":"Electrical Carrier Mobility Measurements of Amorphous Hydrogenated Boron Carbide Using Space-Charge-Limited Current Techniques","abstract":"Within the field of neutron detection, there has been a push to develop solid-state direct-conversion devices. Amorphous hydrogenated boron carbide (a-BxC:Hy) is of particular interest for this purpose because it has a high thermal neutron capture crosssection and high resistivity. To develop an a-BxC:Hy based neutron detector, it is very important to know its charge carrier mobility. Because a-BxC:Hy has a high resistivity and an expectedly low mobility, traditional techniques for measuring mobility, like DC Hall, are not viable. To determine the mobility of a-BxC:Hy, measurement systems based on the steady-state space-charge-limited current (SS-SCLC) and dark-injection space-chargelimited current (DI-SCLC) techniques were developed to get beyond the low mobility limitation. The mobility measurements were performed on a series of a-BxC:Hy samples to determine the range of mobility values and to set a baseline for future research in optimizing the mobility. The samples were found to have very low values for mobility, typically in the range of 10⁻¹² to 10⁻⁹ cm²/(V·s). While this indicates that a-BxC:Hy is unsuitable for thick-film neutron detection, the range in mobility and resistivity values suggests that it can potentially be improved. As such, further research is necessary before an a-BxC:Hy based neutron detector can be fully realized.","abstract_html":"Within the field of neutron detection, there has been a push to develop solid-state direct-conversion devices. Amorphous hydrogenated boron carbide (a-BxC:Hy) is of particular interest for this purpose because it has a high thermal neutron capture crosssection and high resistivity. To develop an a-BxC:Hy based neutron detector, it is very important to know its charge carrier mobility. Because a-BxC:Hy has a high resistivity and an expectedly low mobility, traditional techniques for measuring mobility, like DC Hall, are not viable. To determine the mobility of a-BxC:Hy, measurement systems based on the steady-state space-charge-limited current (SS-SCLC) and dark-injection space-chargelimited current (DI-SCLC) techniques were developed to get beyond the low mobility limitation. The mobility measurements were performed on a series of a-BxC:Hy samples to determine the range of mobility values and to set a baseline for future research in optimizing the mobility. The samples were found to have very low values for mobility, typically in the range of 10⁻¹² to 10⁻⁹ cm²/(V·s). While this indicates that a-BxC:Hy is unsuitable for thick-film neutron detection, the range in mobility and resistivity values suggests that it can potentially be improved. As such, further research is necessary before an a-BxC:Hy based neutron detector can be fully realized.","abstract_has_math":false,"creators":["Keck, Christopher Lawrence"],"institution":"University of Missouri--Kansas City","degree_name":"Masters","degree_level":"Masters","degree_discipline":"Physics (UMKC)","degree_department":null,"school":null,"contributors":[],"advisors":["Paquette, Michelle M."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-08-11","date_published":"2015-08-11","updated_at":"2026-11-19T08:44:13Z","subjects":["Thesis -- University of Missouri--Kansas City -- Physics","Amorphous semiconductors"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10355/46545","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10355/46545","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumkc%3Aoai%3Amospace.umsystem.edu%3A10355%2F46545","prefix":"oai_dc"},"source_record":{"url":"https://mospace.umsystem.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amospace.umsystem.edu%3A10355%2F46545","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Paquette, Michelle M."]},{"key":"dc:creator","label":"Author","values":["Keck, Christopher Lawrence"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-08-11T14:05:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-08-11T14:05:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-08-11"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015 Spring"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics (UMKC)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Masters"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Missouri--Kansas City"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Amorphous semiconductors"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Thesis -- University of Missouri--Kansas City -- Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10355/46545"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Title from PDF of title page, viewed on August 25, 2015","Thesis advisor: Michelle Paquette","Vita","Includes bibliographic references (pages 117-122)","Thesis (M.S.)--Department of Physics and Astronomy. University of Missouri--Kansas City, 2015"]},{"key":"dc:description.abstract","label":"Abstract","values":["Within the field of neutron detection, there has been a push to develop solid-state direct-conversion devices. Amorphous hydrogenated boron carbide (a-BxC:Hy) is of particular interest for this purpose because it has a high thermal neutron capture crosssection and high resistivity. To develop an a-BxC:Hy based neutron detector, it is very important to know its charge carrier mobility. Because a-BxC:Hy has a high resistivity and an expectedly low mobility, traditional techniques for measuring mobility, like DC Hall, are not viable. To determine the mobility of a-BxC:Hy, measurement systems based on the steady-state space-charge-limited current (SS-SCLC) and dark-injection space-chargelimited current (DI-SCLC) techniques were developed to get beyond the low mobility limitation. The mobility measurements were performed on a series of a-BxC:Hy samples to determine the range of mobility values and to set a baseline for future research in optimizing the mobility. The samples were found to have very low values for mobility, typically in the range of 10⁻¹² to 10⁻⁹ cm²/(V·s). While this indicates that a-BxC:Hy is unsuitable for thick-film neutron detection, the range in mobility and resistivity values suggests that it can potentially be improved. As such, further research is necessary before an a-BxC:Hy based neutron detector can be fully realized."]},{"key":"dc:description.tableofcontents","label":"Dc Description Tableofcontents","values":["Introduction -- Theory -- Experimental setup -- Results and discussion -- Conclusion -- Appendix A. SS-SCLC data -- Appendix B. DI-SCLC data"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiii, 123 pages"]},{"key":"dc:title","label":"Title","values":["Electrical Carrier Mobility Measurements of Amorphous Hydrogenated Boron Carbide Using Space-Charge-Limited Current Techniques"]}]}],"canonical_facts":{"dc:contributor.advisor":["Paquette, Michelle M."],"dc:creator":["Keck, Christopher Lawrence"],"dc:date.accessioned":["2015-08-11T14:05:07Z"],"dc:date.available":["2015-08-11T14:05:07Z"],"dc:date.issued":["2015-08-11"],"dc:date.submitted":["2015 Spring"],"dc:description":["Title from PDF of title page, viewed on August 25, 2015","Thesis advisor: Michelle Paquette","Vita","Includes bibliographic references (pages 117-122)","Thesis (M.S.)--Department of Physics and Astronomy. University of Missouri--Kansas City, 2015"],"dc:description.abstract":["Within the field of neutron detection, there has been a push to develop solid-state direct-conversion devices. Amorphous hydrogenated boron carbide (a-BxC:Hy) is of particular interest for this purpose because it has a high thermal neutron capture crosssection and high resistivity. To develop an a-BxC:Hy based neutron detector, it is very important to know its charge carrier mobility. Because a-BxC:Hy has a high resistivity and an expectedly low mobility, traditional techniques for measuring mobility, like DC Hall, are not viable. To determine the mobility of a-BxC:Hy, measurement systems based on the steady-state space-charge-limited current (SS-SCLC) and dark-injection space-chargelimited current (DI-SCLC) techniques were developed to get beyond the low mobility limitation. The mobility measurements were performed on a series of a-BxC:Hy samples to determine the range of mobility values and to set a baseline for future research in optimizing the mobility. The samples were found to have very low values for mobility, typically in the range of 10⁻¹² to 10⁻⁹ cm²/(V·s). While this indicates that a-BxC:Hy is unsuitable for thick-film neutron detection, the range in mobility and resistivity values suggests that it can potentially be improved. As such, further research is necessary before an a-BxC:Hy based neutron detector can be fully realized."],"dc:description.tableofcontents":["Introduction -- Theory -- Experimental setup -- Results and discussion -- Conclusion -- Appendix A. SS-SCLC data -- Appendix B. DI-SCLC data"],"dc:format.extent":["xiii, 123 pages"],"dc:identifier.uri":["https://hdl.handle.net/10355/46545"],"dc:language.iso":["eng"],"dc:subject.lcsh":["Amorphous semiconductors"],"dc:subject.other":["Thesis -- University of Missouri--Kansas City -- Physics"],"dc:title":["Electrical Carrier Mobility Measurements of Amorphous Hydrogenated Boron Carbide Using Space-Charge-Limited Current Techniques"],"dc:type":["Thesis"],"thesis:degree_discipline":["Physics (UMKC)"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Masters"],"thesis:institution_name":["University of Missouri--Kansas City"]},"updated_at":"2026-11-19T08:44:13Z"}