{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/102826"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/102826","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"A fundamental study of high pressure turbine blade trailing edge cooling: an experimental and numerical approach.","abstract":"Experimental and computational results regarding turbulent mixing of passage flow and the coolant from a high-pressure turbine blade trailing edge cooling scheme are documented. Special interest is devoted to gaining a fundamental understanding of the thermal protection provided by the cooling scheme. The trailing edge cooling scheme is a scaled version of a generic scheme, tested in a suction type wind tunnel. The scaled model is three-dimensional with rectangular ribs. Three different lip geometries (square, single round, and double round) are tested. The freestream Reynolds number, based upon the lip thickness, is fixed at 10,200. Primarily, three blowing ratios, M=1.5, M=1.0, and M=0.5 are documented. A hot-wire sensor and a thermocouple are placed inside the slot and detailed measurements of velocities, turbulence intensities, and temperatures are acquired. Values of adiabatic effectiveness obtained on the model surface quantify thermal protection. Spectral analysis of the hot-wire signal is performed at various locations in the flow field. Spectra indicate a coherent mechanism of mixing. This clear unsteadiness is attributed to vortex shedding from the lip. It is shown that effectiveness increases as the blowing ratio increases. This document suggests also that lip geometry is an influential parameter for this cooling scheme. Effectiveness is greatly increased when a rounded lip is utilized. In one case, additional blowing ratios (M=0.75 and M=1.25) were tested. Experiments concluded that above M=1.25, effectiveness is insensitive to blowing ratio. Two-dimensional simulations are presented for M=1.5, M=1.0 and M=0.5. They use various Reynolds Averaged Navier Stokes turbulence closure models. The frequencies of unsteadiness are well modeled but, in general, effectiveness is over-predicted. Furthermore, general features of the flow and thermal fields are modeled well, but surface heat transfer characteristics are not.","abstract_html":"Experimental and computational results regarding turbulent mixing of passage flow and the coolant from a high-pressure turbine blade trailing edge cooling scheme are documented. Special interest is devoted to gaining a fundamental understanding of the thermal protection provided by the cooling scheme. The trailing edge cooling scheme is a scaled version of a generic scheme, tested in a suction type wind tunnel. The scaled model is three-dimensional with rectangular ribs. Three different lip geometries (square, single round, and double round) are tested. The freestream Reynolds number, based upon the lip thickness, is fixed at 10,200. Primarily, three blowing ratios, M=1.5, M=1.0, and M=0.5 are documented. A hot-wire sensor and a thermocouple are placed inside the slot and detailed measurements of velocities, turbulence intensities, and temperatures are acquired. Values of adiabatic effectiveness obtained on the model surface quantify thermal protection. Spectral analysis of the hot-wire signal is performed at various locations in the flow field. Spectra indicate a coherent mechanism of mixing. This clear unsteadiness is attributed to vortex shedding from the lip. It is shown that effectiveness increases as the blowing ratio increases. This document suggests also that lip geometry is an influential parameter for this cooling scheme. Effectiveness is greatly increased when a rounded lip is utilized. In one case, additional blowing ratios (M=0.75 and M=1.25) were tested. Experiments concluded that above M=1.25, effectiveness is insensitive to blowing ratio. Two-dimensional simulations are presented for M=1.5, M=1.0 and M=0.5. They use various Reynolds Averaged Navier Stokes turbulence closure models. The frequencies of unsteadiness are well modeled but, in general, effectiveness is over-predicted. Furthermore, general features of the flow and thermal fields are modeled well, but surface heat transfer characteristics are not.","abstract_has_math":false,"creators":["Boomsma, Aaron Anno"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-11","date_published":"2010-11","updated_at":"2026-11-19T08:36:56Z","subjects":["Thermal protection","Cooling scheme","Lip geometry","Hot-wire","Thermal fields","Mechanical Engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Boomsma, Aaron Anno. (2010). A fundamental study of high pressure turbine blade trailing edge cooling: an experimental and numerical approach.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/102826."],"render_values":[{"text":"Boomsma, Aaron Anno. (2010). A fundamental study of high pressure turbine blade trailing edge cooling: an experimental and numerical approach.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/102826.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/102826","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/102826","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F102826","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F102826","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Boomsma, Aaron Anno"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-04-15T19:29:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-04-15T19:29:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Thermal protection","Cooling scheme","Lip geometry","Hot-wire","Thermal fields","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Boomsma, Aaron Anno. (2010). A fundamental study of high pressure turbine blade trailing edge cooling: an experimental and numerical approach.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/102826."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/102826"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. November 2010. Major: Mechanical Engineering. Advisor: Dr. Terrence W. Simon. 1 computer file (PDF); xii, 126 pages, appendix p. 121-126. Ill. (some col.)"]},{"key":"dc:description.abstract","label":"Abstract","values":["Experimental and computational results regarding turbulent mixing of passage flow and the coolant from a high-pressure turbine blade trailing edge cooling scheme are documented. Special interest is devoted to gaining a fundamental understanding of the thermal protection provided by the cooling scheme. The trailing edge cooling scheme is a scaled version of a generic scheme, tested in a suction type wind tunnel. The scaled model is three-dimensional with rectangular ribs. Three different lip geometries (square, single round, and double round) are tested. The freestream Reynolds number, based upon the lip thickness, is fixed at 10,200. Primarily, three blowing ratios, M=1.5, M=1.0, and M=0.5 are documented. A hot-wire sensor and a thermocouple are placed inside the slot and detailed measurements of velocities, turbulence intensities, and temperatures are acquired. Values of adiabatic effectiveness obtained on the model surface quantify thermal protection. Spectral analysis of the hot-wire signal is performed at various locations in the flow field. Spectra indicate a coherent mechanism of mixing. This clear unsteadiness is attributed to vortex shedding from the lip. It is shown that effectiveness increases as the blowing ratio increases. This document suggests also that lip geometry is an influential parameter for this cooling scheme. Effectiveness is greatly increased when a rounded lip is utilized. In one case, additional blowing ratios (M=0.75 and M=1.25) were tested. Experiments concluded that above M=1.25, effectiveness is insensitive to blowing ratio. Two-dimensional simulations are presented for M=1.5, M=1.0 and M=0.5. They use various Reynolds Averaged Navier Stokes turbulence closure models. The frequencies of unsteadiness are well modeled but, in general, effectiveness is over-predicted. Furthermore, general features of the flow and thermal fields are modeled well, but surface heat transfer characteristics are not."]},{"key":"dc:title","label":"Title","values":["A fundamental study of high pressure turbine blade trailing edge cooling: an experimental and numerical approach."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Boomsma, Aaron Anno"],"dc:date.accessioned":["2011-04-15T19:29:39Z"],"dc:date.available":["2011-04-15T19:29:39Z"],"dc:date.issued":["2010-11"],"dc:description":["University of Minnesota M.S. thesis. November 2010. Major: Mechanical Engineering. Advisor: Dr. Terrence W. Simon. 1 computer file (PDF); xii, 126 pages, appendix p. 121-126. Ill. (some col.)"],"dc:description.abstract":["Experimental and computational results regarding turbulent mixing of passage flow and the coolant from a high-pressure turbine blade trailing edge cooling scheme are documented. Special interest is devoted to gaining a fundamental understanding of the thermal protection provided by the cooling scheme. The trailing edge cooling scheme is a scaled version of a generic scheme, tested in a suction type wind tunnel. The scaled model is three-dimensional with rectangular ribs. Three different lip geometries (square, single round, and double round) are tested. The freestream Reynolds number, based upon the lip thickness, is fixed at 10,200. Primarily, three blowing ratios, M=1.5, M=1.0, and M=0.5 are documented. A hot-wire sensor and a thermocouple are placed inside the slot and detailed measurements of velocities, turbulence intensities, and temperatures are acquired. Values of adiabatic effectiveness obtained on the model surface quantify thermal protection. Spectral analysis of the hot-wire signal is performed at various locations in the flow field. Spectra indicate a coherent mechanism of mixing. This clear unsteadiness is attributed to vortex shedding from the lip. It is shown that effectiveness increases as the blowing ratio increases. This document suggests also that lip geometry is an influential parameter for this cooling scheme. Effectiveness is greatly increased when a rounded lip is utilized. In one case, additional blowing ratios (M=0.75 and M=1.25) were tested. Experiments concluded that above M=1.25, effectiveness is insensitive to blowing ratio. Two-dimensional simulations are presented for M=1.5, M=1.0 and M=0.5. They use various Reynolds Averaged Navier Stokes turbulence closure models. The frequencies of unsteadiness are well modeled but, in general, effectiveness is over-predicted. Furthermore, general features of the flow and thermal fields are modeled well, but surface heat transfer characteristics are not."],"dc:identifier.citation":["Boomsma, Aaron Anno. (2010). A fundamental study of high pressure turbine blade trailing edge cooling: an experimental and numerical approach.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/102826."],"dc:identifier.uri":["http://purl.umn.edu/102826"],"dc:language.iso":["en_US"],"dc:subject":["Thermal protection","Cooling scheme","Lip geometry","Hot-wire","Thermal fields","Mechanical Engineering"],"dc:title":["A fundamental study of high pressure turbine blade trailing edge cooling: an experimental and numerical approach."],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:36:56Z"}