{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/131209"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/131209","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Peripheral nerve conduction block with high frequency stimulation via percutaneous lead electrode.","abstract":"Nerve conduction block elicited by high frequency electrical stimulation may be used to create chronic neuroprostheses to treat diseases that are characterized by pathological nervous activities. Previous studies have demonstrated that local and reversible nerve conduction block can be achieved using high frequency stimulation (3-6 kHz and above) delivered through cuff electrodes. However, cuff electrodes are designed to be placed encircling the nerve and demands invasive surgical procedure that may not be desired by patients in clinical applications. This study investigated the nerve block effect of high frequency stimulation delivered through a percutaneous lead placed next a motor nerve trunk in dogs. The optimal frequency and amplitude windows for nerve block using a biphasic rectangular waveform were 10-30 kHz and 15-20 V peak-to-peak within the tested parameter range (5-40 kHz and 5-20 V). Higher frequencies may require higher amplitudes to achieve nerve block effect. In addition, activation threshold of the nerve evoked by the biphasic high frequency stimulation also increased with frequency. The HFS nerve block was repeatable in more than 40 minutes of repetitive stimulation. This study demonstrated that it is feasible to achieve local reversible nerve block using percutaneous lead electrodes placed next to a nerve with biphasic high frequency waveform. Although it may be difficult to block all the nerve fibers in a nerve trunk with a percutaneous lead, partial nerve block can be clinically useful and desired in many disease conditions.","abstract_html":"Nerve conduction block elicited by high frequency electrical stimulation may be used to create chronic neuroprostheses to treat diseases that are characterized by pathological nervous activities. Previous studies have demonstrated that local and reversible nerve conduction block can be achieved using high frequency stimulation (3-6 kHz and above) delivered through cuff electrodes. However, cuff electrodes are designed to be placed encircling the nerve and demands invasive surgical procedure that may not be desired by patients in clinical applications. This study investigated the nerve block effect of high frequency stimulation delivered through a percutaneous lead placed next a motor nerve trunk in dogs. The optimal frequency and amplitude windows for nerve block using a biphasic rectangular waveform were 10-30 kHz and 15-20 V peak-to-peak within the tested parameter range (5-40 kHz and 5-20 V). Higher frequencies may require higher amplitudes to achieve nerve block effect. In addition, activation threshold of the nerve evoked by the biphasic high frequency stimulation also increased with frequency. The HFS nerve block was repeatable in more than 40 minutes of repetitive stimulation. This study demonstrated that it is feasible to achieve local reversible nerve block using percutaneous lead electrodes placed next to a nerve with biphasic high frequency waveform. Although it may be difficult to block all the nerve fibers in a nerve trunk with a percutaneous lead, partial nerve block can be clinically useful and desired in many disease conditions.","abstract_has_math":false,"creators":["Wei, Xuan"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-05","date_published":"2011-05","updated_at":"2026-11-19T08:37:08Z","subjects":["Integrarive biology and physiology"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Wei, Xuan. (2011). Peripheral nerve conduction block with high frequency stimulation via percutaneous lead electrode.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131209."],"render_values":[{"text":"Wei, Xuan. (2011). Peripheral nerve conduction block with high frequency stimulation via percutaneous lead electrode.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131209.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/131209","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/131209","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F131209","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Wei, Xuan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-14T15:13:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-14T15:13:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-05"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Integrarive biology and physiology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Wei, Xuan. (2011). Peripheral nerve conduction block with high frequency stimulation via percutaneous lead electrode.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131209."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/131209"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. Major: Integrarive biology and physiology. Advisor:John W. Osborn. 1 computer file (PDF); x, 46 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Nerve conduction block elicited by high frequency electrical stimulation may be used to create chronic neuroprostheses to treat diseases that are characterized by pathological nervous activities. Previous studies have demonstrated that local and reversible nerve conduction block can be achieved using high frequency stimulation (3-6 kHz and above) delivered through cuff electrodes. However, cuff electrodes are designed to be placed encircling the nerve and demands invasive surgical procedure that may not be desired by patients in clinical applications. This study investigated the nerve block effect of high frequency stimulation delivered through a percutaneous lead placed next a motor nerve trunk in dogs. The optimal frequency and amplitude windows for nerve block using a biphasic rectangular waveform were 10-30 kHz and 15-20 V peak-to-peak within the tested parameter range (5-40 kHz and 5-20 V). Higher frequencies may require higher amplitudes to achieve nerve block effect. In addition, activation threshold of the nerve evoked by the biphasic high frequency stimulation also increased with frequency. The HFS nerve block was repeatable in more than 40 minutes of repetitive stimulation. This study demonstrated that it is feasible to achieve local reversible nerve block using percutaneous lead electrodes placed next to a nerve with biphasic high frequency waveform. Although it may be difficult to block all the nerve fibers in a nerve trunk with a percutaneous lead, partial nerve block can be clinically useful and desired in many disease conditions."]},{"key":"dc:title","label":"Title","values":["Peripheral nerve conduction block with high frequency stimulation via percutaneous lead electrode."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Wei, Xuan"],"dc:date.accessioned":["2012-08-14T15:13:18Z"],"dc:date.available":["2012-08-14T15:13:18Z"],"dc:date.issued":["2011-05"],"dc:description":["University of Minnesota M.S. thesis. Major: Integrarive biology and physiology. Advisor:John W. Osborn. 1 computer file (PDF); x, 46 pages."],"dc:description.abstract":["Nerve conduction block elicited by high frequency electrical stimulation may be used to create chronic neuroprostheses to treat diseases that are characterized by pathological nervous activities. Previous studies have demonstrated that local and reversible nerve conduction block can be achieved using high frequency stimulation (3-6 kHz and above) delivered through cuff electrodes. However, cuff electrodes are designed to be placed encircling the nerve and demands invasive surgical procedure that may not be desired by patients in clinical applications. This study investigated the nerve block effect of high frequency stimulation delivered through a percutaneous lead placed next a motor nerve trunk in dogs. The optimal frequency and amplitude windows for nerve block using a biphasic rectangular waveform were 10-30 kHz and 15-20 V peak-to-peak within the tested parameter range (5-40 kHz and 5-20 V). Higher frequencies may require higher amplitudes to achieve nerve block effect. In addition, activation threshold of the nerve evoked by the biphasic high frequency stimulation also increased with frequency. The HFS nerve block was repeatable in more than 40 minutes of repetitive stimulation. This study demonstrated that it is feasible to achieve local reversible nerve block using percutaneous lead electrodes placed next to a nerve with biphasic high frequency waveform. Although it may be difficult to block all the nerve fibers in a nerve trunk with a percutaneous lead, partial nerve block can be clinically useful and desired in many disease conditions."],"dc:identifier.citation":["Wei, Xuan. (2011). Peripheral nerve conduction block with high frequency stimulation via percutaneous lead electrode.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131209."],"dc:identifier.uri":["http://purl.umn.edu/131209"],"dc:language.iso":["en_US"],"dc:subject":["Integrarive biology and physiology"],"dc:title":["Peripheral nerve conduction block with high frequency stimulation via percutaneous lead electrode."],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:37:08Z"}