{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/131468"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/131468","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Psychophysical thresholds are more precise measures of proprioceptive sensitivity than matching error values at the elbow joint.","abstract":"To assess proprioceptive function, clinicians employ joint position matching tasks. However, the reliability and validity of matching tasks are infrequently considered. Laboratory tests of proprioceptive sensitivity include more controlled matching methods that yield position error measures or psychophysical methods that yield a perceptual threshold. Psychophysical methods have been shown to be both valid and reliable. In this study, proprioceptive sensitivity of the elbow joint was assessed in 24 healthy adult volunteers using an ipsilateral matching method and a psychophysical method. The aims of the study were: 1) to determine if threshold measures obtained by psychophysical testing yield more precise measures of position sense than error measures obtained by an ipsilateral joint position matching method and 2) to determine if the two methods are linearly correlated with each other. The results indicated that the psychophysical method provided more precise measurements than the ipsilateral matching method. Despite both assessments measuring position sense sensitivity of the elbow, they were poorly linearly correlated with each other. Based on the findings, the study demonstrated that the psychophysical method provided a more precise measure of proprioceptive sensitivity at the elbow than the ipsilateral matching method.","abstract_html":"To assess proprioceptive function, clinicians employ joint position matching tasks. However, the reliability and validity of matching tasks are infrequently considered. Laboratory tests of proprioceptive sensitivity include more controlled matching methods that yield position error measures or psychophysical methods that yield a perceptual threshold. Psychophysical methods have been shown to be both valid and reliable. In this study, proprioceptive sensitivity of the elbow joint was assessed in 24 healthy adult volunteers using an ipsilateral matching method and a psychophysical method. The aims of the study were: 1) to determine if threshold measures obtained by psychophysical testing yield more precise measures of position sense than error measures obtained by an ipsilateral joint position matching method and 2) to determine if the two methods are linearly correlated with each other. The results indicated that the psychophysical method provided more precise measurements than the ipsilateral matching method. Despite both assessments measuring position sense sensitivity of the elbow, they were poorly linearly correlated with each other. Based on the findings, the study demonstrated that the psychophysical method provided a more precise measure of proprioceptive sensitivity at the elbow than the ipsilateral matching method.","abstract_has_math":false,"creators":["Herrmann, Amanda Ann"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06","date_published":"2012-06","updated_at":"2026-11-19T08:37:08Z","subjects":["Ipsilateral matching","Joint position matching","Position sensitivity","Proprioceptive performance","Proprioceptive sensitivity","Psychophysical testing","Kinesiology"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Herrmann, Amanda Ann. (2012). Psychophysical thresholds are more precise measures of proprioceptive sensitivity than matching error values at the elbow joint.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131468."],"render_values":[{"text":"Herrmann, Amanda Ann. (2012). Psychophysical thresholds are more precise measures of proprioceptive sensitivity than matching error values at the elbow joint.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131468.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/131468","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/131468","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F131468","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F131468","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Herrmann, Amanda Ann"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-16T14:42:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-16T14:42:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ipsilateral matching","Joint position matching","Position sensitivity","Proprioceptive performance","Proprioceptive sensitivity","Psychophysical testing","Kinesiology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Herrmann, Amanda Ann. (2012). Psychophysical thresholds are more precise measures of proprioceptive sensitivity than matching error values at the elbow joint.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131468."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/131468"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. June 2012. Major: Kinesiology. Advisor: Dr. Jürgen Konczak. 1 computer file (PDF); v, 27 pages, appendices A-B."]},{"key":"dc:description.abstract","label":"Abstract","values":["To assess proprioceptive function, clinicians employ joint position matching tasks. However, the reliability and validity of matching tasks are infrequently considered. Laboratory tests of proprioceptive sensitivity include more controlled matching methods that yield position error measures or psychophysical methods that yield a perceptual threshold. Psychophysical methods have been shown to be both valid and reliable. In this study, proprioceptive sensitivity of the elbow joint was assessed in 24 healthy adult volunteers using an ipsilateral matching method and a psychophysical method. The aims of the study were: 1) to determine if threshold measures obtained by psychophysical testing yield more precise measures of position sense than error measures obtained by an ipsilateral joint position matching method and 2) to determine if the two methods are linearly correlated with each other. The results indicated that the psychophysical method provided more precise measurements than the ipsilateral matching method. Despite both assessments measuring position sense sensitivity of the elbow, they were poorly linearly correlated with each other. Based on the findings, the study demonstrated that the psychophysical method provided a more precise measure of proprioceptive sensitivity at the elbow than the ipsilateral matching method."]},{"key":"dc:title","label":"Title","values":["Psychophysical thresholds are more precise measures of proprioceptive sensitivity than matching error values at the elbow joint."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Herrmann, Amanda Ann"],"dc:date.accessioned":["2012-08-16T14:42:36Z"],"dc:date.available":["2012-08-16T14:42:36Z"],"dc:date.issued":["2012-06"],"dc:description":["University of Minnesota M.S. thesis. June 2012. Major: Kinesiology. Advisor: Dr. Jürgen Konczak. 1 computer file (PDF); v, 27 pages, appendices A-B."],"dc:description.abstract":["To assess proprioceptive function, clinicians employ joint position matching tasks. However, the reliability and validity of matching tasks are infrequently considered. Laboratory tests of proprioceptive sensitivity include more controlled matching methods that yield position error measures or psychophysical methods that yield a perceptual threshold. Psychophysical methods have been shown to be both valid and reliable. In this study, proprioceptive sensitivity of the elbow joint was assessed in 24 healthy adult volunteers using an ipsilateral matching method and a psychophysical method. The aims of the study were: 1) to determine if threshold measures obtained by psychophysical testing yield more precise measures of position sense than error measures obtained by an ipsilateral joint position matching method and 2) to determine if the two methods are linearly correlated with each other. The results indicated that the psychophysical method provided more precise measurements than the ipsilateral matching method. Despite both assessments measuring position sense sensitivity of the elbow, they were poorly linearly correlated with each other. Based on the findings, the study demonstrated that the psychophysical method provided a more precise measure of proprioceptive sensitivity at the elbow than the ipsilateral matching method."],"dc:identifier.citation":["Herrmann, Amanda Ann. (2012). Psychophysical thresholds are more precise measures of proprioceptive sensitivity than matching error values at the elbow joint.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131468."],"dc:identifier.uri":["http://purl.umn.edu/131468"],"dc:language.iso":["en_US"],"dc:subject":["Ipsilateral matching","Joint position matching","Position sensitivity","Proprioceptive performance","Proprioceptive sensitivity","Psychophysical testing","Kinesiology"],"dc:title":["Psychophysical thresholds are more precise measures of proprioceptive sensitivity than matching error values at the elbow joint."],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:37:08Z"}