{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/143722"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/143722","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis","abstract":"Statement of problem: The use of short dental implants is usually confined to areas of the mouth with limited vertical bone height. As a result, longer implant crowns are required to restore the occlusion with the opposing arch, leading to a disproportionate crown-to-implant ratio (C/I ratio). Purpose: The purpose of this study was to evaluate the stress distribution patterns on crestal bone of short implants plateau-designed connected with different crown heights, and to compare these findings with those of regular implants. Material and Methods: Two implant designs (∅5 mm×6 mm and ∅5 mm×11 mm) and abutments (∅5 mm×9 mm and ∅5 mm×5 mm) were scanned using a micro-CT scanner. STL surface models were subsequently extracted to generate surfaces. All models were imported to Abaqus CAE for three-dimensional non-linear finite element analysis. For each implant model, loadings of 100, 200, and 700 N were simulated in 2 directions: pure vertical and at an oblique angle of 15 degrees. Results: At 100 and 200 N oblique loads, peak compressive and tensile stresses ranged from 18.30 to 53.57 MPa and 7.39 to 43.95 MPa, respectively. At 700 N oblique loads, the ∅5 mm×6 mm implant with long abutment model exceeded the compressive and tensile strength of cortical bone, at 193.4 and 158.6 MPa correspondingly. For 700 N oblique loads, increasing crown height increased peak compressive stress by 28.6 % and peak tensile stress by 28.4 %. Stress distribution patterns showed the highest amounts of stress located at the implant crest module in cortical bone. Conclusion: Stress distribution patterns for the oblique loads of 100 and 200 N were similar in all models, regardless of the C/I ratios. All peak stresses were within physiological tolerance. At 700 N loads, increasing crown height resulted in bone failure.","abstract_html":"Statement of problem: The use of short dental implants is usually confined to areas of the mouth with limited vertical bone height. As a result, longer implant crowns are required to restore the occlusion with the opposing arch, leading to a disproportionate crown-to-implant ratio (C/I ratio). Purpose: The purpose of this study was to evaluate the stress distribution patterns on crestal bone of short implants plateau-designed connected with different crown heights, and to compare these findings with those of regular implants. Material and Methods: Two implant designs (∅5 mm×6 mm and ∅5 mm×11 mm) and abutments (∅5 mm×9 mm and ∅5 mm×5 mm) were scanned using a micro-CT scanner. STL surface models were subsequently extracted to generate surfaces. All models were imported to Abaqus CAE for three-dimensional non-linear finite element analysis. For each implant model, loadings of 100, 200, and 700 N were simulated in 2 directions: pure vertical and at an oblique angle of 15 degrees. Results: At 100 and 200 N oblique loads, peak compressive and tensile stresses ranged from 18.30 to 53.57 MPa and 7.39 to 43.95 MPa, respectively. At 700 N oblique loads, the ∅5 mm×6 mm implant with long abutment model exceeded the compressive and tensile strength of cortical bone, at 193.4 and 158.6 MPa correspondingly. For 700 N oblique loads, increasing crown height increased peak compressive stress by 28.6 % and peak tensile stress by 28.4 %. Stress distribution patterns showed the highest amounts of stress located at the implant crest module in cortical bone. Conclusion: Stress distribution patterns for the oblique loads of 100 and 200 N were similar in all models, regardless of the C/I ratios. All peak stresses were within physiological tolerance. At 700 N loads, increasing crown height resulted in bone failure.","abstract_has_math":false,"creators":["Ritkajorn, Tanawat"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-12","date_published":"2010-12","updated_at":"2026-11-19T08:37:19Z","subjects":["Dentistry"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ritkajorn, Tanawat. (2010). Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/143722."],"render_values":[{"text":"Ritkajorn, Tanawat. (2010). Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/143722.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/143722","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/143722","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F143722","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F143722","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ritkajorn, Tanawat"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-30T22:19:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-30T22:19:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-12"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ritkajorn, Tanawat. (2010). Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/143722."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/143722"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. December 2010. Major: Dentistry. Advisor: Alex S. L. Fok, PhD. 1 computer file (PDF); vii, 47 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Statement of problem: The use of short dental implants is usually confined to areas of the mouth with limited vertical bone height. As a result, longer implant crowns are required to restore the occlusion with the opposing arch, leading to a disproportionate crown-to-implant ratio (C/I ratio). Purpose: The purpose of this study was to evaluate the stress distribution patterns on crestal bone of short implants plateau-designed connected with different crown heights, and to compare these findings with those of regular implants. Material and Methods: Two implant designs (∅5 mm×6 mm and ∅5 mm×11 mm) and abutments (∅5 mm×9 mm and ∅5 mm×5 mm) were scanned using a micro-CT scanner. STL surface models were subsequently extracted to generate surfaces. All models were imported to Abaqus CAE for three-dimensional non-linear finite element analysis. For each implant model, loadings of 100, 200, and 700 N were simulated in 2 directions: pure vertical and at an oblique angle of 15 degrees. Results: At 100 and 200 N oblique loads, peak compressive and tensile stresses ranged from 18.30 to 53.57 MPa and 7.39 to 43.95 MPa, respectively. At 700 N oblique loads, the ∅5 mm×6 mm implant with long abutment model exceeded the compressive and tensile strength of cortical bone, at 193.4 and 158.6 MPa correspondingly. For 700 N oblique loads, increasing crown height increased peak compressive stress by 28.6 % and peak tensile stress by 28.4 %. Stress distribution patterns showed the highest amounts of stress located at the implant crest module in cortical bone. Conclusion: Stress distribution patterns for the oblique loads of 100 and 200 N were similar in all models, regardless of the C/I ratios. All peak stresses were within physiological tolerance. At 700 N loads, increasing crown height resulted in bone failure."]},{"key":"dc:title","label":"Title","values":["Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Ritkajorn, Tanawat"],"dc:date.accessioned":["2013-01-30T22:19:43Z"],"dc:date.available":["2013-01-30T22:19:43Z"],"dc:date.issued":["2010-12"],"dc:description":["University of Minnesota M.S. thesis. December 2010. Major: Dentistry. Advisor: Alex S. L. Fok, PhD. 1 computer file (PDF); vii, 47 pages."],"dc:description.abstract":["Statement of problem: The use of short dental implants is usually confined to areas of the mouth with limited vertical bone height. As a result, longer implant crowns are required to restore the occlusion with the opposing arch, leading to a disproportionate crown-to-implant ratio (C/I ratio). Purpose: The purpose of this study was to evaluate the stress distribution patterns on crestal bone of short implants plateau-designed connected with different crown heights, and to compare these findings with those of regular implants. Material and Methods: Two implant designs (∅5 mm×6 mm and ∅5 mm×11 mm) and abutments (∅5 mm×9 mm and ∅5 mm×5 mm) were scanned using a micro-CT scanner. STL surface models were subsequently extracted to generate surfaces. All models were imported to Abaqus CAE for three-dimensional non-linear finite element analysis. For each implant model, loadings of 100, 200, and 700 N were simulated in 2 directions: pure vertical and at an oblique angle of 15 degrees. Results: At 100 and 200 N oblique loads, peak compressive and tensile stresses ranged from 18.30 to 53.57 MPa and 7.39 to 43.95 MPa, respectively. At 700 N oblique loads, the ∅5 mm×6 mm implant with long abutment model exceeded the compressive and tensile strength of cortical bone, at 193.4 and 158.6 MPa correspondingly. For 700 N oblique loads, increasing crown height increased peak compressive stress by 28.6 % and peak tensile stress by 28.4 %. Stress distribution patterns showed the highest amounts of stress located at the implant crest module in cortical bone. Conclusion: Stress distribution patterns for the oblique loads of 100 and 200 N were similar in all models, regardless of the C/I ratios. All peak stresses were within physiological tolerance. At 700 N loads, increasing crown height resulted in bone failure."],"dc:identifier.citation":["Ritkajorn, Tanawat. (2010). Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/143722."],"dc:identifier.uri":["http://purl.umn.edu/143722"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry"],"dc:title":["Evaluation of stress distribution patterns on short implants with differing crown heights: a three dimensional finite element analysis"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:37:19Z"}