{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/152354"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/152354","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Optimizing sample preparation and scanning methods for component analysis of raw milk by fourier transform near infrared spectroscopy","abstract":"Raw milk is hard to analyze by NIR because of light scattering caused by large particles in the fat component; however, improvements to sample preparation and presentation could improve analysis. In this study, sample presentation and particle size reduction using homogenization was investigated for 160 diverse samples to predict component quantities in raw milk by FT-NIR. Excellent standard errors were obtained for all measured components following no-homogenization. Sonication and tube-dispersion methods were not different than no-homogenization, but were better compared to two-stage homogenization for moisture and casein due to whey protein denaturation during processing. High sample temperatures during analysis likely contributed to positive results for all component predictions compared to references. For sample presentation, static and dynamic flow-cell methods produced the best standard errors for components. Meanwhile, petri-dish presentation was accurate but may have been limited by the method design, which allowed for sample dehydration and loss of reflected light.","abstract_html":"Raw milk is hard to analyze by NIR because of light scattering caused by large particles in the fat component; however, improvements to sample preparation and presentation could improve analysis. In this study, sample presentation and particle size reduction using homogenization was investigated for 160 diverse samples to predict component quantities in raw milk by FT-NIR. Excellent standard errors were obtained for all measured components following no-homogenization. Sonication and tube-dispersion methods were not different than no-homogenization, but were better compared to two-stage homogenization for moisture and casein due to whey protein denaturation during processing. High sample temperatures during analysis likely contributed to positive results for all component predictions compared to references. For sample presentation, static and dynamic flow-cell methods produced the best standard errors for components. Meanwhile, petri-dish presentation was accurate but may have been limited by the method design, which allowed for sample dehydration and loss of reflected light.","abstract_has_math":false,"creators":["Reuter, Anthony Joseph"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-04","date_published":"2013-04","updated_at":"2026-11-19T08:37:28Z","subjects":["Homogenization","Milk analysis","Near-infrared spectroscopy","NIR","Sample preparation","Sample presentation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Reuter, Anthony Joseph. (2013). Optimizing sample preparation and scanning methods for component analysis of raw milk by fourier transform near infrared spectroscopy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/152354."],"render_values":[{"text":"Reuter, Anthony Joseph. (2013). Optimizing sample preparation and scanning methods for component analysis of raw milk by fourier transform near infrared spectroscopy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/152354.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/152354","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/152354","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F152354","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F152354","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Reuter, Anthony Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-07-10T18:36:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-07-10T18:36:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-04"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Homogenization","Milk analysis","Near-infrared spectroscopy","NIR","Sample preparation","Sample presentation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Reuter, Anthony Joseph. (2013). Optimizing sample preparation and scanning methods for component analysis of raw milk by fourier transform near infrared spectroscopy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/152354."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/152354"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. April 2013. Major: Food science. Advisors: Tonya Schoenfuss, Ph.D., Leonard Marquart, Ph.D., R.D. 1 computer file (PDF); vii, 143 pages, appendix p. 104-143."]},{"key":"dc:description.abstract","label":"Abstract","values":["Raw milk is hard to analyze by NIR because of light scattering caused by large particles in the fat component; however, improvements to sample preparation and presentation could improve analysis. In this study, sample presentation and particle size reduction using homogenization was investigated for 160 diverse samples to predict component quantities in raw milk by FT-NIR. Excellent standard errors were obtained for all measured components following no-homogenization. Sonication and tube-dispersion methods were not different than no-homogenization, but were better compared to two-stage homogenization for moisture and casein due to whey protein denaturation during processing. High sample temperatures during analysis likely contributed to positive results for all component predictions compared to references. For sample presentation, static and dynamic flow-cell methods produced the best standard errors for components. Meanwhile, petri-dish presentation was accurate but may have been limited by the method design, which allowed for sample dehydration and loss of reflected light."]},{"key":"dc:title","label":"Title","values":["Optimizing sample preparation and scanning methods for component analysis of raw milk by fourier transform near infrared spectroscopy"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Reuter, Anthony Joseph"],"dc:date.accessioned":["2013-07-10T18:36:06Z"],"dc:date.available":["2013-07-10T18:36:06Z"],"dc:date.issued":["2013-04"],"dc:description":["University of Minnesota M.S. thesis. April 2013. Major: Food science. Advisors: Tonya Schoenfuss, Ph.D., Leonard Marquart, Ph.D., R.D. 1 computer file (PDF); vii, 143 pages, appendix p. 104-143."],"dc:description.abstract":["Raw milk is hard to analyze by NIR because of light scattering caused by large particles in the fat component; however, improvements to sample preparation and presentation could improve analysis. In this study, sample presentation and particle size reduction using homogenization was investigated for 160 diverse samples to predict component quantities in raw milk by FT-NIR. Excellent standard errors were obtained for all measured components following no-homogenization. Sonication and tube-dispersion methods were not different than no-homogenization, but were better compared to two-stage homogenization for moisture and casein due to whey protein denaturation during processing. High sample temperatures during analysis likely contributed to positive results for all component predictions compared to references. For sample presentation, static and dynamic flow-cell methods produced the best standard errors for components. Meanwhile, petri-dish presentation was accurate but may have been limited by the method design, which allowed for sample dehydration and loss of reflected light."],"dc:identifier.citation":["Reuter, Anthony Joseph. (2013). Optimizing sample preparation and scanning methods for component analysis of raw milk by fourier transform near infrared spectroscopy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/152354."],"dc:identifier.uri":["http://purl.umn.edu/152354"],"dc:language.iso":["en_US"],"dc:subject":["Homogenization","Milk analysis","Near-infrared spectroscopy","NIR","Sample preparation","Sample presentation"],"dc:title":["Optimizing sample preparation and scanning methods for component analysis of raw milk by fourier transform near infrared spectroscopy"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:37:28Z"}