{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/156570"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/156570","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Experimental investigation of the effect of engine representative combustor exit temperature profile and disc cavity leakage flow on the film cooling of contoured Hub Endwall of a high pressure gas turbine rotor cascade","abstract":"The effects of an engine representative combustor exit temperature profile on the adiabatic effectiveness values on a contoured turbine hub endwall at different disc cavity leakage flow rates are documented. Measurements for passage thermal fields and endwall adiabatic effectiveness values are made for disc cavity leakage mass flow rates of 0.5%, 1.0 % and 1.5 % of the mainstream passage flow; in presence of an engine representative combustor exit temperature profile. The endwall contour resembles the shape of a `shark nose'. Endwall adiabatic effectiveness values for the `shark nose' profile have been compared with those with a different endwall profile called `dolphin nose'. Also, augmentation in adiabatic effectiveness by using an engine representative combustor exit temperature profile relative to other profiles has been documented. The results indicate that increasing leakage flow rates leads to a more uniform distribution of adiabatic effectiveness values in the pitchwise direction at the passage entrance. Also, the presence of additional coolant in the near wall approach flow, leads to significant endwall cooling near the passage exit.","abstract_html":"The effects of an engine representative combustor exit temperature profile on the adiabatic effectiveness values on a contoured turbine hub endwall at different disc cavity leakage flow rates are documented. Measurements for passage thermal fields and endwall adiabatic effectiveness values are made for disc cavity leakage mass flow rates of 0.5%, 1.0 % and 1.5 % of the mainstream passage flow; in presence of an engine representative combustor exit temperature profile. The endwall contour resembles the shape of a `shark nose&#x27;. Endwall adiabatic effectiveness values for the `shark nose&#x27; profile have been compared with those with a different endwall profile called `dolphin nose&#x27;. Also, augmentation in adiabatic effectiveness by using an engine representative combustor exit temperature profile relative to other profiles has been documented. The results indicate that increasing leakage flow rates leads to a more uniform distribution of adiabatic effectiveness values in the pitchwise direction at the passage entrance. Also, the presence of additional coolant in the near wall approach flow, leads to significant endwall cooling near the passage exit.","abstract_has_math":false,"creators":["Ayaskanta, Arya"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-05","date_published":"2013-05","updated_at":"2026-11-19T08:37:28Z","subjects":["Adiabatic effectiveness","Combustor exit profile","Contouring","Endwall heat transfer","Leakage flow"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ayaskanta, Arya. (2013). Experimental investigation of the effect of engine representative combustor exit temperature profile and disc cavity leakage flow on the film cooling of contoured Hub Endwall of a high pressure gas turbine rotor cascade. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/156570."],"render_values":[{"text":"Ayaskanta, Arya. (2013). Experimental investigation of the effect of engine representative combustor exit temperature profile and disc cavity leakage flow on the film cooling of contoured Hub Endwall of a high pressure gas turbine rotor cascade. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/156570.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/156570","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/156570","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F156570","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F156570","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ayaskanta, Arya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-09-10T18:46:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-09-10T18:46:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-05"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Adiabatic effectiveness","Combustor exit profile","Contouring","Endwall heat transfer","Leakage flow"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ayaskanta, Arya. (2013). Experimental investigation of the effect of engine representative combustor exit temperature profile and disc cavity leakage flow on the film cooling of contoured Hub Endwall of a high pressure gas turbine rotor cascade. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/156570."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/156570"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. May 2013. Major: Mechanical Engineering. Advisor: Terrence W. Simon. 1 computer file (PDF); xii, 123 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["The effects of an engine representative combustor exit temperature profile on the adiabatic effectiveness values on a contoured turbine hub endwall at different disc cavity leakage flow rates are documented. Measurements for passage thermal fields and endwall adiabatic effectiveness values are made for disc cavity leakage mass flow rates of 0.5%, 1.0 % and 1.5 % of the mainstream passage flow; in presence of an engine representative combustor exit temperature profile. The endwall contour resembles the shape of a `shark nose'. Endwall adiabatic effectiveness values for the `shark nose' profile have been compared with those with a different endwall profile called `dolphin nose'. Also, augmentation in adiabatic effectiveness by using an engine representative combustor exit temperature profile relative to other profiles has been documented. The results indicate that increasing leakage flow rates leads to a more uniform distribution of adiabatic effectiveness values in the pitchwise direction at the passage entrance. Also, the presence of additional coolant in the near wall approach flow, leads to significant endwall cooling near the passage exit."]},{"key":"dc:title","label":"Title","values":["Experimental investigation of the effect of engine representative combustor exit temperature profile and disc cavity leakage flow on the film cooling of contoured Hub Endwall of a high pressure gas turbine rotor cascade"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Ayaskanta, Arya"],"dc:date.accessioned":["2013-09-10T18:46:44Z"],"dc:date.available":["2013-09-10T18:46:44Z"],"dc:date.issued":["2013-05"],"dc:description":["University of Minnesota M.S. thesis. May 2013. Major: Mechanical Engineering. Advisor: Terrence W. Simon. 1 computer file (PDF); xii, 123 pages."],"dc:description.abstract":["The effects of an engine representative combustor exit temperature profile on the adiabatic effectiveness values on a contoured turbine hub endwall at different disc cavity leakage flow rates are documented. Measurements for passage thermal fields and endwall adiabatic effectiveness values are made for disc cavity leakage mass flow rates of 0.5%, 1.0 % and 1.5 % of the mainstream passage flow; in presence of an engine representative combustor exit temperature profile. The endwall contour resembles the shape of a `shark nose'. Endwall adiabatic effectiveness values for the `shark nose' profile have been compared with those with a different endwall profile called `dolphin nose'. Also, augmentation in adiabatic effectiveness by using an engine representative combustor exit temperature profile relative to other profiles has been documented. The results indicate that increasing leakage flow rates leads to a more uniform distribution of adiabatic effectiveness values in the pitchwise direction at the passage entrance. Also, the presence of additional coolant in the near wall approach flow, leads to significant endwall cooling near the passage exit."],"dc:identifier.citation":["Ayaskanta, Arya. (2013). Experimental investigation of the effect of engine representative combustor exit temperature profile and disc cavity leakage flow on the film cooling of contoured Hub Endwall of a high pressure gas turbine rotor cascade. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/156570."],"dc:identifier.uri":["http://purl.umn.edu/156570"],"dc:language.iso":["en_US"],"dc:subject":["Adiabatic effectiveness","Combustor exit profile","Contouring","Endwall heat transfer","Leakage flow"],"dc:title":["Experimental investigation of the effect of engine representative combustor exit temperature profile and disc cavity leakage flow on the film cooling of contoured Hub Endwall of a high pressure gas turbine rotor cascade"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:37:28Z"}