{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/162282"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/162282","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Event detection for post lung transplant based on home monitoring of spirometry and symptoms","abstract":"The goal of this dissertation research was to develop, implement, and test an automated decision system to provide early detection of actual acute bronchopulmonary events in a population of lung transplant recipients following a home monitoring protocol. Decision rules were developed using wavelet analysis of spirometry and symptom signal data collected daily at home by the lung transplant recipients, and transmitted weekly to our study data center. Rules were developed based on a learning set of patient home data, and validated with an independent set of patients. Using either FEV1 or symptom-based home data monitoring, the detection algorithm can capture the majority of events (sensitivity > 80%) at an acceptable level of false alarms. Detection occurs 6.6 to 10.8 days earlier than the corresponding events recorded in the patient's clinical records. Combining rules using the Dempster-Shafer theory of evidence incrementally improves performance over a single variable. This framework can be readily implemented as an automatic event detection tool to aid medical discovery and diagnosis of acute pulmonary events.","abstract_html":"The goal of this dissertation research was to develop, implement, and test an automated decision system to provide early detection of actual acute bronchopulmonary events in a population of lung transplant recipients following a home monitoring protocol. Decision rules were developed using wavelet analysis of spirometry and symptom signal data collected daily at home by the lung transplant recipients, and transmitted weekly to our study data center. Rules were developed based on a learning set of patient home data, and validated with an independent set of patients. Using either FEV1 or symptom-based home data monitoring, the detection algorithm can capture the majority of events (sensitivity &gt; 80%) at an acceptable level of false alarms. Detection occurs 6.6 to 10.8 days earlier than the corresponding events recorded in the patient&#x27;s clinical records. Combining rules using the Dempster-Shafer theory of evidence incrementally improves performance over a single variable. This framework can be readily implemented as an automatic event detection tool to aid medical discovery and diagnosis of acute pulmonary events.","abstract_has_math":false,"creators":["Wang, Xuewe"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-12","date_published":"2011-12","updated_at":"2026-11-19T08:37:38Z","subjects":["Dempster-Shafer","Event detection","Home monitoring","Lung transplant","Spirometry","Wavelets"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Wang, Xuewe. (2011). Event detection for post lung transplant based on home monitoring of spirometry and symptoms. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/162282."],"render_values":[{"text":"Wang, Xuewe. (2011). Event detection for post lung transplant based on home monitoring of spirometry and symptoms. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/162282.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/162282","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/162282","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F162282","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Wang, Xuewe"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-01-09T22:26:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-01-09T22:26:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-12"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dempster-Shafer","Event detection","Home monitoring","Lung transplant","Spirometry","Wavelets"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Wang, Xuewe. (2011). Event detection for post lung transplant based on home monitoring of spirometry and symptoms. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/162282."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11299/162282"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota Ph.D. dissertation. December 2011. Major: Biomedical Engineering. Advisor: Stanley M. Finkelstein. 1 computer file (PDF); x, 150 pages, appendices p. 129-150."]},{"key":"dc:description.abstract","label":"Abstract","values":["The goal of this dissertation research was to develop, implement, and test an automated decision system to provide early detection of actual acute bronchopulmonary events in a population of lung transplant recipients following a home monitoring protocol. Decision rules were developed using wavelet analysis of spirometry and symptom signal data collected daily at home by the lung transplant recipients, and transmitted weekly to our study data center. Rules were developed based on a learning set of patient home data, and validated with an independent set of patients. Using either FEV1 or symptom-based home data monitoring, the detection algorithm can capture the majority of events (sensitivity > 80%) at an acceptable level of false alarms. Detection occurs 6.6 to 10.8 days earlier than the corresponding events recorded in the patient's clinical records. Combining rules using the Dempster-Shafer theory of evidence incrementally improves performance over a single variable. This framework can be readily implemented as an automatic event detection tool to aid medical discovery and diagnosis of acute pulmonary events."]},{"key":"dc:title","label":"Title","values":["Event detection for post lung transplant based on home monitoring of spirometry and symptoms"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Wang, Xuewe"],"dc:date.accessioned":["2014-01-09T22:26:39Z"],"dc:date.available":["2014-01-09T22:26:39Z"],"dc:date.issued":["2011-12"],"dc:description":["University of Minnesota Ph.D. dissertation. December 2011. Major: Biomedical Engineering. Advisor: Stanley M. Finkelstein. 1 computer file (PDF); x, 150 pages, appendices p. 129-150."],"dc:description.abstract":["The goal of this dissertation research was to develop, implement, and test an automated decision system to provide early detection of actual acute bronchopulmonary events in a population of lung transplant recipients following a home monitoring protocol. Decision rules were developed using wavelet analysis of spirometry and symptom signal data collected daily at home by the lung transplant recipients, and transmitted weekly to our study data center. Rules were developed based on a learning set of patient home data, and validated with an independent set of patients. Using either FEV1 or symptom-based home data monitoring, the detection algorithm can capture the majority of events (sensitivity > 80%) at an acceptable level of false alarms. Detection occurs 6.6 to 10.8 days earlier than the corresponding events recorded in the patient's clinical records. Combining rules using the Dempster-Shafer theory of evidence incrementally improves performance over a single variable. This framework can be readily implemented as an automatic event detection tool to aid medical discovery and diagnosis of acute pulmonary events."],"dc:identifier.citation":["Wang, Xuewe. (2011). Event detection for post lung transplant based on home monitoring of spirometry and symptoms. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/162282."],"dc:identifier.uri":["http://hdl.handle.net/11299/162282"],"dc:language.iso":["en_US"],"dc:subject":["Dempster-Shafer","Event detection","Home monitoring","Lung transplant","Spirometry","Wavelets"],"dc:title":["Event detection for post lung transplant based on home monitoring of spirometry and symptoms"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:37:38Z"}