{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/165458"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/165458","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"In vitro testing of the accuracy of a computerized pantograph","abstract":"Statement of the problem. The accuracy of a computerized pantograph has not been confirmed in laboratory or clinical studies.Specific aims. The purpose of this in vitro study is to test the accuracy of a computerized pantograph to record predetermined condylar settings on a fully adjustable articulator for condylar inclination with flat versus 3/8\" inserts, top wall, rear wall, progressive side shift, and immediate side shift. Materials and methods. Computerized pantographic sensors were mounted on a fully adjustable articulator with an arbitrary determination of the hinge axis. Tracings were made on the articulator with known condylar settings for condylar inclination with flat and 3/8\" curved inserts, immediate side shift, progressive side shift, top wall and rear wall. Means, standard deviations, P-values, equivalence testing and Bonferonni adjustments were determined for each condylar setting.Results. The computerized pantograph accurately recorded the immediate side shift at 0, 1.2 mm and 2.0 mm (P<.0001). Condylar inclination with the 3/8\" curved insert at 10 and 25 degrees was accurately determined at the 10 mm condylotrack distance (P<.0001). Condylar inclination with the flat insert, progressive side shift, top wall and rear wall were non-significant.Conclusion. The computerized pantograph is a valid instrument for recording immediate side shift and condylar inclination with a curved 3/8\" fossa at the 10 mm condylotrack distance.","abstract_html":"Statement of the problem. The accuracy of a computerized pantograph has not been confirmed in laboratory or clinical studies.Specific aims. The purpose of this in vitro study is to test the accuracy of a computerized pantograph to record predetermined condylar settings on a fully adjustable articulator for condylar inclination with flat versus 3/8&quot; inserts, top wall, rear wall, progressive side shift, and immediate side shift. Materials and methods. Computerized pantographic sensors were mounted on a fully adjustable articulator with an arbitrary determination of the hinge axis. Tracings were made on the articulator with known condylar settings for condylar inclination with flat and 3/8&quot; curved inserts, immediate side shift, progressive side shift, top wall and rear wall. Means, standard deviations, P-values, equivalence testing and Bonferonni adjustments were determined for each condylar setting.Results. The computerized pantograph accurately recorded the immediate side shift at 0, 1.2 mm and 2.0 mm (P&lt;.0001). Condylar inclination with the 3/8&quot; curved insert at 10 and 25 degrees was accurately determined at the 10 mm condylotrack distance (P&lt;.0001). Condylar inclination with the flat insert, progressive side shift, top wall and rear wall were non-significant.Conclusion. The computerized pantograph is a valid instrument for recording immediate side shift and condylar inclination with a curved 3/8&quot; fossa at the 10 mm condylotrack distance.","abstract_has_math":false,"creators":["Dryer, Richard"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-06","date_published":"2014-06","updated_at":"2026-11-19T08:37:48Z","subjects":["Computerized Pantograph","Horizontal Condylar Inclination","Immediate Side Shift","In Vitro","Mandbibular movement","Pantographic Tracing"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dryer, Richard. (2014). In vitro testing of the accuracy of a computerized pantograph. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/165458."],"render_values":[{"text":"Dryer, Richard. (2014). In vitro testing of the accuracy of a computerized pantograph. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/165458.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11299/165458","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11299/165458","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F165458","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Dryer, Richard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-09-08T14:50:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-09-08T14:50:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computerized Pantograph","Horizontal Condylar Inclination","Immediate Side Shift","In Vitro","Mandbibular movement","Pantographic Tracing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dryer, Richard. (2014). In vitro testing of the accuracy of a computerized pantograph. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/165458."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11299/165458"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. June 2014. Major: Dentistry. Advisor: Heather J. Conrad, D.M.D., M.S. 1 computer file (PDF); vi, 50 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Statement of the problem. The accuracy of a computerized pantograph has not been confirmed in laboratory or clinical studies.Specific aims. The purpose of this in vitro study is to test the accuracy of a computerized pantograph to record predetermined condylar settings on a fully adjustable articulator for condylar inclination with flat versus 3/8\" inserts, top wall, rear wall, progressive side shift, and immediate side shift. Materials and methods. Computerized pantographic sensors were mounted on a fully adjustable articulator with an arbitrary determination of the hinge axis. Tracings were made on the articulator with known condylar settings for condylar inclination with flat and 3/8\" curved inserts, immediate side shift, progressive side shift, top wall and rear wall. Means, standard deviations, P-values, equivalence testing and Bonferonni adjustments were determined for each condylar setting.Results. The computerized pantograph accurately recorded the immediate side shift at 0, 1.2 mm and 2.0 mm (P<.0001). Condylar inclination with the 3/8\" curved insert at 10 and 25 degrees was accurately determined at the 10 mm condylotrack distance (P<.0001). Condylar inclination with the flat insert, progressive side shift, top wall and rear wall were non-significant.Conclusion. The computerized pantograph is a valid instrument for recording immediate side shift and condylar inclination with a curved 3/8\" fossa at the 10 mm condylotrack distance."]},{"key":"dc:title","label":"Title","values":["In vitro testing of the accuracy of a computerized pantograph"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Dryer, Richard"],"dc:date.accessioned":["2014-09-08T14:50:29Z"],"dc:date.available":["2014-09-08T14:50:29Z"],"dc:date.issued":["2014-06"],"dc:description":["University of Minnesota M.S. thesis. June 2014. Major: Dentistry. Advisor: Heather J. Conrad, D.M.D., M.S. 1 computer file (PDF); vi, 50 pages."],"dc:description.abstract":["Statement of the problem. The accuracy of a computerized pantograph has not been confirmed in laboratory or clinical studies.Specific aims. The purpose of this in vitro study is to test the accuracy of a computerized pantograph to record predetermined condylar settings on a fully adjustable articulator for condylar inclination with flat versus 3/8\" inserts, top wall, rear wall, progressive side shift, and immediate side shift. Materials and methods. Computerized pantographic sensors were mounted on a fully adjustable articulator with an arbitrary determination of the hinge axis. Tracings were made on the articulator with known condylar settings for condylar inclination with flat and 3/8\" curved inserts, immediate side shift, progressive side shift, top wall and rear wall. Means, standard deviations, P-values, equivalence testing and Bonferonni adjustments were determined for each condylar setting.Results. The computerized pantograph accurately recorded the immediate side shift at 0, 1.2 mm and 2.0 mm (P<.0001). Condylar inclination with the 3/8\" curved insert at 10 and 25 degrees was accurately determined at the 10 mm condylotrack distance (P<.0001). Condylar inclination with the flat insert, progressive side shift, top wall and rear wall were non-significant.Conclusion. The computerized pantograph is a valid instrument for recording immediate side shift and condylar inclination with a curved 3/8\" fossa at the 10 mm condylotrack distance."],"dc:identifier.citation":["Dryer, Richard. (2014). In vitro testing of the accuracy of a computerized pantograph. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/165458."],"dc:identifier.uri":["http://hdl.handle.net/11299/165458"],"dc:language.iso":["en_US"],"dc:subject":["Computerized Pantograph","Horizontal Condylar Inclination","Immediate Side Shift","In Vitro","Mandbibular movement","Pantographic Tracing"],"dc:title":["In vitro testing of the accuracy of a computerized pantograph"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:37:48Z"}