{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/174790"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/174790","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Clinical Testing of the Precision of a Digital Condylogram","abstract":"Purpose: This study was designed to determine the repeatability of a digital condylogram to generate condylar recordings on patients at two separate time periods. Materials and Methods: A digital condylogram was used on 16 patients to record condylar movements at two separate time periods approximately 1 month apart. Data manager software was used to calculate recommended settings of a Denar D5A fully adjustable articulator for each trial. The differences between the calculated angles of trials 1 and 2 for each patient were determined and analyzed. Results: Immediate side shift (ISS) and progressive side shift (PSS) demonstrated significant differences on average between trial 1 and 2. Variation between the trials was large, particularly for rear wall and top wall angles. The average amount of time that elapsed between trials 1 and 2 did not have a significant effect on the results. Conclusion: The digital condylogram records sagittal condylar inclination, rear wall and top wall angles predictably over time; however, ISS and PSS were not recorded predictably. Results demonstrated significant variation that may be due to the patients' abilities to reproduce jaw movements precisely or that may be due to the operator's ability to connect the condylogram predictably.","abstract_html":"Purpose: This study was designed to determine the repeatability of a digital condylogram to generate condylar recordings on patients at two separate time periods. Materials and Methods: A digital condylogram was used on 16 patients to record condylar movements at two separate time periods approximately 1 month apart. Data manager software was used to calculate recommended settings of a Denar D5A fully adjustable articulator for each trial. The differences between the calculated angles of trials 1 and 2 for each patient were determined and analyzed. Results: Immediate side shift (ISS) and progressive side shift (PSS) demonstrated significant differences on average between trial 1 and 2. Variation between the trials was large, particularly for rear wall and top wall angles. The average amount of time that elapsed between trials 1 and 2 did not have a significant effect on the results. Conclusion: The digital condylogram records sagittal condylar inclination, rear wall and top wall angles predictably over time; however, ISS and PSS were not recorded predictably. Results demonstrated significant variation that may be due to the patients&#x27; abilities to reproduce jaw movements precisely or that may be due to the operator&#x27;s ability to connect the condylogram predictably.","abstract_has_math":false,"creators":["Keyes, John"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-03","date_published":"2015-03","updated_at":"2026-11-19T08:38:10Z","subjects":["Condylar movement","Condylogram","Digital Pantograph","Fully adjustable articulator","Movements of the mandible","Pantogram"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Keyes, John. (2015). Clinical Testing of the Precision of a Digital Condylogram. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/174790."],"render_values":[{"text":"Keyes, John. (2015). Clinical Testing of the Precision of a Digital Condylogram. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/174790.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/174790","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/174790","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F174790","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F174790","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Keyes, John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-10-13T18:52:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-10-13T18:52:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-03"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Condylar movement","Condylogram","Digital Pantograph","Fully adjustable articulator","Movements of the mandible","Pantogram"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Keyes, John. (2015). Clinical Testing of the Precision of a Digital Condylogram. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/174790."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11299/174790"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. March 2015. Major: Dentistry. Advisor: Heather Conrad. 1 computer file (PDF); vi, 43 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: This study was designed to determine the repeatability of a digital condylogram to generate condylar recordings on patients at two separate time periods. Materials and Methods: A digital condylogram was used on 16 patients to record condylar movements at two separate time periods approximately 1 month apart. Data manager software was used to calculate recommended settings of a Denar D5A fully adjustable articulator for each trial. The differences between the calculated angles of trials 1 and 2 for each patient were determined and analyzed. Results: Immediate side shift (ISS) and progressive side shift (PSS) demonstrated significant differences on average between trial 1 and 2. Variation between the trials was large, particularly for rear wall and top wall angles. The average amount of time that elapsed between trials 1 and 2 did not have a significant effect on the results. Conclusion: The digital condylogram records sagittal condylar inclination, rear wall and top wall angles predictably over time; however, ISS and PSS were not recorded predictably. Results demonstrated significant variation that may be due to the patients' abilities to reproduce jaw movements precisely or that may be due to the operator's ability to connect the condylogram predictably."]},{"key":"dc:title","label":"Title","values":["Clinical Testing of the Precision of a Digital Condylogram"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Keyes, John"],"dc:date.accessioned":["2015-10-13T18:52:43Z"],"dc:date.available":["2015-10-13T18:52:43Z"],"dc:date.issued":["2015-03"],"dc:description":["University of Minnesota M.S. thesis. March 2015. Major: Dentistry. Advisor: Heather Conrad. 1 computer file (PDF); vi, 43 pages."],"dc:description.abstract":["Purpose: This study was designed to determine the repeatability of a digital condylogram to generate condylar recordings on patients at two separate time periods. Materials and Methods: A digital condylogram was used on 16 patients to record condylar movements at two separate time periods approximately 1 month apart. Data manager software was used to calculate recommended settings of a Denar D5A fully adjustable articulator for each trial. The differences between the calculated angles of trials 1 and 2 for each patient were determined and analyzed. Results: Immediate side shift (ISS) and progressive side shift (PSS) demonstrated significant differences on average between trial 1 and 2. Variation between the trials was large, particularly for rear wall and top wall angles. The average amount of time that elapsed between trials 1 and 2 did not have a significant effect on the results. Conclusion: The digital condylogram records sagittal condylar inclination, rear wall and top wall angles predictably over time; however, ISS and PSS were not recorded predictably. Results demonstrated significant variation that may be due to the patients' abilities to reproduce jaw movements precisely or that may be due to the operator's ability to connect the condylogram predictably."],"dc:identifier.citation":["Keyes, John. (2015). Clinical Testing of the Precision of a Digital Condylogram. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/174790."],"dc:identifier.uri":["http://hdl.handle.net/11299/174790"],"dc:language.iso":["en"],"dc:subject":["Condylar movement","Condylogram","Digital Pantograph","Fully adjustable articulator","Movements of the mandible","Pantogram"],"dc:title":["Clinical Testing of the Precision of a Digital Condylogram"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:38:10Z"}