{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/181815"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/181815","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"A Novel Method for Assessing Leg Compartmental Body Composition Using Dual Energy X-Ray Absorptiometry","abstract":"PURPOSE: Investigate the validity and reliability of a novel lateral dual energy X-ray absorptiometry (DXA) scanning method for total, fat, and lean tissue mass quantification of the anterior and posterior thigh compartments. METHODS: Twenty-one (11 female; X̅age=20.3±1.3 yrs) college athletes participated, with segmentation of anterior/posterior thigh compartments completed via laterally-positioned DXA scans. Three technicians created custom regions of interest (ROIs) using bony landmarks for each scan via enCoreTM software. Paired t-tests (lateral vs. standard frontal position) evaluated the validity of this novel method while intra-class correlations (ICCs) and coefficients of variation (CV) examined intra-/inter-rater reliability. RESULTS: Total, fat, and lean mass comparisons between frontal and lateral DXA scans were non-significant (p-values: 0.15-0.74). High ICCs were observed between-/within-raters (0.983-0.999 and 0.954-0.999, respectively), with low variation across all measures (CVs: <5%). CONCLUSION: DXA measures using lateral positioning and custom ROIs for tissue mass quantification are valid and reliable versus standard frontal positioning.","abstract_html":"PURPOSE: Investigate the validity and reliability of a novel lateral dual energy X-ray absorptiometry (DXA) scanning method for total, fat, and lean tissue mass quantification of the anterior and posterior thigh compartments. METHODS: Twenty-one (11 female; X̅age=20.3±1.3 yrs) college athletes participated, with segmentation of anterior/posterior thigh compartments completed via laterally-positioned DXA scans. Three technicians created custom regions of interest (ROIs) using bony landmarks for each scan via enCoreTM software. Paired t-tests (lateral vs. standard frontal position) evaluated the validity of this novel method while intra-class correlations (ICCs) and coefficients of variation (CV) examined intra-/inter-rater reliability. RESULTS: Total, fat, and lean mass comparisons between frontal and lateral DXA scans were non-significant (p-values: 0.15-0.74). High ICCs were observed between-/within-raters (0.983-0.999 and 0.954-0.999, respectively), with low variation across all measures (CVs: &lt;5%). CONCLUSION: DXA measures using lateral positioning and custom ROIs for tissue mass quantification are valid and reliable versus standard frontal positioning.","abstract_has_math":false,"creators":["Raymond, Christiana"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05","date_published":"2016-05","updated_at":"2026-11-19T08:38:40Z","subjects":["Body Composition","Dual Energy X-Ray Absorptiometry","Reliability","Validity"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Raymond, Christiana. (2016). A Novel Method for Assessing Leg Compartmental Body Composition Using Dual Energy X-Ray Absorptiometry. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/181815."],"render_values":[{"text":"Raymond, Christiana. (2016). A Novel Method for Assessing Leg Compartmental Body Composition Using Dual Energy X-Ray Absorptiometry. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/181815.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11299/181815","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11299/181815","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F181815","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Raymond, Christiana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-19T19:18:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-19T19:18:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-05"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Body Composition","Dual Energy X-Ray Absorptiometry","Reliability","Validity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Raymond, Christiana. (2016). A Novel Method for Assessing Leg Compartmental Body Composition Using Dual Energy X-Ray Absorptiometry. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/181815."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11299/181815"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. May 2016. Major: Kinesiology. Advisor: Donald Dengel. 1 computer file (PDF); ix, 66 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["PURPOSE: Investigate the validity and reliability of a novel lateral dual energy X-ray absorptiometry (DXA) scanning method for total, fat, and lean tissue mass quantification of the anterior and posterior thigh compartments. METHODS: Twenty-one (11 female; X̅age=20.3±1.3 yrs) college athletes participated, with segmentation of anterior/posterior thigh compartments completed via laterally-positioned DXA scans. Three technicians created custom regions of interest (ROIs) using bony landmarks for each scan via enCoreTM software. Paired t-tests (lateral vs. standard frontal position) evaluated the validity of this novel method while intra-class correlations (ICCs) and coefficients of variation (CV) examined intra-/inter-rater reliability. RESULTS: Total, fat, and lean mass comparisons between frontal and lateral DXA scans were non-significant (p-values: 0.15-0.74). High ICCs were observed between-/within-raters (0.983-0.999 and 0.954-0.999, respectively), with low variation across all measures (CVs: <5%). CONCLUSION: DXA measures using lateral positioning and custom ROIs for tissue mass quantification are valid and reliable versus standard frontal positioning."]},{"key":"dc:title","label":"Title","values":["A Novel Method for Assessing Leg Compartmental Body Composition Using Dual Energy X-Ray Absorptiometry"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Raymond, Christiana"],"dc:date.accessioned":["2016-08-19T19:18:39Z"],"dc:date.available":["2016-08-19T19:18:39Z"],"dc:date.issued":["2016-05"],"dc:description":["University of Minnesota M.S. thesis. May 2016. Major: Kinesiology. Advisor: Donald Dengel. 1 computer file (PDF); ix, 66 pages."],"dc:description.abstract":["PURPOSE: Investigate the validity and reliability of a novel lateral dual energy X-ray absorptiometry (DXA) scanning method for total, fat, and lean tissue mass quantification of the anterior and posterior thigh compartments. METHODS: Twenty-one (11 female; X̅age=20.3±1.3 yrs) college athletes participated, with segmentation of anterior/posterior thigh compartments completed via laterally-positioned DXA scans. Three technicians created custom regions of interest (ROIs) using bony landmarks for each scan via enCoreTM software. Paired t-tests (lateral vs. standard frontal position) evaluated the validity of this novel method while intra-class correlations (ICCs) and coefficients of variation (CV) examined intra-/inter-rater reliability. RESULTS: Total, fat, and lean mass comparisons between frontal and lateral DXA scans were non-significant (p-values: 0.15-0.74). High ICCs were observed between-/within-raters (0.983-0.999 and 0.954-0.999, respectively), with low variation across all measures (CVs: <5%). CONCLUSION: DXA measures using lateral positioning and custom ROIs for tissue mass quantification are valid and reliable versus standard frontal positioning."],"dc:identifier.citation":["Raymond, Christiana. (2016). A Novel Method for Assessing Leg Compartmental Body Composition Using Dual Energy X-Ray Absorptiometry. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/181815."],"dc:identifier.uri":["http://hdl.handle.net/11299/181815"],"dc:language.iso":["en"],"dc:subject":["Body Composition","Dual Energy X-Ray Absorptiometry","Reliability","Validity"],"dc:title":["A Novel Method for Assessing Leg Compartmental Body Composition Using Dual Energy X-Ray Absorptiometry"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:38:40Z"}