{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/182110"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/182110","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times","abstract":"Purpose: The purpose of this study was to evaluate the effects of polymerization time and sectioning on the dimensional changes of auto-polymerizing acrylic resin used in splinting impression copings and the resulting fit of the prosthesis. Materials and Methods: Open-tray impression copings were connected to a master cast containing 5 external-hex implants. Auto-polymerizing acrylic resin was allowed to polymerize in a heavy-body polyvinyl siloxane matrix according to 3 different time groups (8 minutes (8MN), 1 hour (1HR), and 24 hours (24HR)), with 20 sets of splinted impression copings per time group. Each time group was further divided into non- sectioned (NS) and sectioned (S) groups (10 samples per group). A total of 60 gypsum bases were fabricated from implant analogs connected to the impression copings. A milled titanium bar fabricated from the master cast was used to verify the fit of the bar to the implant analogs. The casts were viewed using loupes (2.5x magnification) and a microscope (12.8x magnification) to visually detect any gap. The gap sizes were evaluated with a measuring gauge with pre-determined thickness in microns (μm). Results: Of the 30 casts tested in the sectioned groups (8MN-S, 1HR-S, and 24HR-S), all of the casts displayed clinical fit when evaluated with magnification loupes and a dental explorer. From this evaluation, only the 8MN-S group showed statistical significant difference (p < 0.05) when compared to its non-sectioned counterpart (8MN- NS). When evaluated with a microscope, no significant differences were found between the different time groups or sectioned samples. The microscope was able to detect gaps that were not detectable with magnification loupes and a dental explorer. Conclusion: Overall, difference in polymerization time and sectioning did not have an effect on the accuracy of fit. Sectioning for the 8-minute time group did show an improvement in the fit when compared to the non-sectioned samples. Although clinical fit appeared to be present, it did not always indicate the presence of absolute fit.","abstract_html":"Purpose: The purpose of this study was to evaluate the effects of polymerization time and sectioning on the dimensional changes of auto-polymerizing acrylic resin used in splinting impression copings and the resulting fit of the prosthesis. Materials and Methods: Open-tray impression copings were connected to a master cast containing 5 external-hex implants. Auto-polymerizing acrylic resin was allowed to polymerize in a heavy-body polyvinyl siloxane matrix according to 3 different time groups (8 minutes (8MN), 1 hour (1HR), and 24 hours (24HR)), with 20 sets of splinted impression copings per time group. Each time group was further divided into non- sectioned (NS) and sectioned (S) groups (10 samples per group). A total of 60 gypsum bases were fabricated from implant analogs connected to the impression copings. A milled titanium bar fabricated from the master cast was used to verify the fit of the bar to the implant analogs. The casts were viewed using loupes (2.5x magnification) and a microscope (12.8x magnification) to visually detect any gap. The gap sizes were evaluated with a measuring gauge with pre-determined thickness in microns (μm). Results: Of the 30 casts tested in the sectioned groups (8MN-S, 1HR-S, and 24HR-S), all of the casts displayed clinical fit when evaluated with magnification loupes and a dental explorer. From this evaluation, only the 8MN-S group showed statistical significant difference (p &lt; 0.05) when compared to its non-sectioned counterpart (8MN- NS). When evaluated with a microscope, no significant differences were found between the different time groups or sectioned samples. The microscope was able to detect gaps that were not detectable with magnification loupes and a dental explorer. Conclusion: Overall, difference in polymerization time and sectioning did not have an effect on the accuracy of fit. Sectioning for the 8-minute time group did show an improvement in the fit when compared to the non-sectioned samples. Although clinical fit appeared to be present, it did not always indicate the presence of absolute fit.","abstract_has_math":false,"creators":["Kiangsoontra, Jason"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05","date_published":"2016-05","updated_at":"2026-11-19T08:38:40Z","subjects":["Acrylic Resin","Implants","Impression","Polymerization Time","Setting Time","Splinting Material"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Kiangsoontra, Jason. (2016). Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/182110."],"render_values":[{"text":"Kiangsoontra, Jason. (2016). Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/182110.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/182110","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/182110","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F182110","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F182110","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kiangsoontra, Jason"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-09-19T14:46:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-19T14:46:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-05"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Acrylic Resin","Implants","Impression","Polymerization Time","Setting Time","Splinting Material"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Kiangsoontra, Jason. (2016). Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/182110."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11299/182110"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. May 2016. Major: Dentistry. Advisor: Heather Conrad. 1 computer file (PDF); vii, 71 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: The purpose of this study was to evaluate the effects of polymerization time and sectioning on the dimensional changes of auto-polymerizing acrylic resin used in splinting impression copings and the resulting fit of the prosthesis. Materials and Methods: Open-tray impression copings were connected to a master cast containing 5 external-hex implants. Auto-polymerizing acrylic resin was allowed to polymerize in a heavy-body polyvinyl siloxane matrix according to 3 different time groups (8 minutes (8MN), 1 hour (1HR), and 24 hours (24HR)), with 20 sets of splinted impression copings per time group. Each time group was further divided into non- sectioned (NS) and sectioned (S) groups (10 samples per group). A total of 60 gypsum bases were fabricated from implant analogs connected to the impression copings. A milled titanium bar fabricated from the master cast was used to verify the fit of the bar to the implant analogs. The casts were viewed using loupes (2.5x magnification) and a microscope (12.8x magnification) to visually detect any gap. The gap sizes were evaluated with a measuring gauge with pre-determined thickness in microns (μm). Results: Of the 30 casts tested in the sectioned groups (8MN-S, 1HR-S, and 24HR-S), all of the casts displayed clinical fit when evaluated with magnification loupes and a dental explorer. From this evaluation, only the 8MN-S group showed statistical significant difference (p < 0.05) when compared to its non-sectioned counterpart (8MN- NS). When evaluated with a microscope, no significant differences were found between the different time groups or sectioned samples. The microscope was able to detect gaps that were not detectable with magnification loupes and a dental explorer. Conclusion: Overall, difference in polymerization time and sectioning did not have an effect on the accuracy of fit. Sectioning for the 8-minute time group did show an improvement in the fit when compared to the non-sectioned samples. Although clinical fit appeared to be present, it did not always indicate the presence of absolute fit."]},{"key":"dc:title","label":"Title","values":["Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Kiangsoontra, Jason"],"dc:date.accessioned":["2016-09-19T14:46:10Z"],"dc:date.available":["2016-09-19T14:46:10Z"],"dc:date.issued":["2016-05"],"dc:description":["University of Minnesota M.S. thesis. May 2016. Major: Dentistry. Advisor: Heather Conrad. 1 computer file (PDF); vii, 71 pages."],"dc:description.abstract":["Purpose: The purpose of this study was to evaluate the effects of polymerization time and sectioning on the dimensional changes of auto-polymerizing acrylic resin used in splinting impression copings and the resulting fit of the prosthesis. Materials and Methods: Open-tray impression copings were connected to a master cast containing 5 external-hex implants. Auto-polymerizing acrylic resin was allowed to polymerize in a heavy-body polyvinyl siloxane matrix according to 3 different time groups (8 minutes (8MN), 1 hour (1HR), and 24 hours (24HR)), with 20 sets of splinted impression copings per time group. Each time group was further divided into non- sectioned (NS) and sectioned (S) groups (10 samples per group). A total of 60 gypsum bases were fabricated from implant analogs connected to the impression copings. A milled titanium bar fabricated from the master cast was used to verify the fit of the bar to the implant analogs. The casts were viewed using loupes (2.5x magnification) and a microscope (12.8x magnification) to visually detect any gap. The gap sizes were evaluated with a measuring gauge with pre-determined thickness in microns (μm). Results: Of the 30 casts tested in the sectioned groups (8MN-S, 1HR-S, and 24HR-S), all of the casts displayed clinical fit when evaluated with magnification loupes and a dental explorer. From this evaluation, only the 8MN-S group showed statistical significant difference (p < 0.05) when compared to its non-sectioned counterpart (8MN- NS). When evaluated with a microscope, no significant differences were found between the different time groups or sectioned samples. The microscope was able to detect gaps that were not detectable with magnification loupes and a dental explorer. Conclusion: Overall, difference in polymerization time and sectioning did not have an effect on the accuracy of fit. Sectioning for the 8-minute time group did show an improvement in the fit when compared to the non-sectioned samples. Although clinical fit appeared to be present, it did not always indicate the presence of absolute fit."],"dc:identifier.citation":["Kiangsoontra, Jason. (2016). Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/182110."],"dc:identifier.uri":["http://hdl.handle.net/11299/182110"],"dc:language.iso":["en"],"dc:subject":["Acrylic Resin","Implants","Impression","Polymerization Time","Setting Time","Splinting Material"],"dc:title":["Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:38:40Z"}