{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/200142"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/200142","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Comparison of Resistance to Sliding Between Metal Lined Ceramic Brackets and Unlined Ceramic Brackets: An In Vitro Study","abstract":"Objective: Comparing resistance to sliding (RS) between esthetic brackets under an increasing applied moment. Materials and Methods: Three different brackets were mounted on a testing apparatus to simulate canine retraction using sliding mechanics and application of a moment on 0.019”x0.025” nickel-titanium and stainless steel archwires. The samples examined were: ClarityTM Advanced, and ClarityTM metal-reinforced, and VictoryTM series brackets. The RS at calculated moments of 1000 g-mm, 2000 g-mm, and 3000 g-mm was determined and compared between the various brackets. Descriptive measures and one-way analysis of variance were used to calculate means and statistical differences among the bracket types. Results: No significant difference in RS between the brackets was found on nickel-titanium arch wires. The ClarityTM Advanced bracket had significantly greater (P < 0.05) RS than the other brackets tested at all three calculated moments on stainless steel archwires. Conclusion: ClarityTM Advanced brackets had significantly higher RS on stainless steel archwires.","abstract_html":"Objective: Comparing resistance to sliding (RS) between esthetic brackets under an increasing applied moment. Materials and Methods: Three different brackets were mounted on a testing apparatus to simulate canine retraction using sliding mechanics and application of a moment on 0.019”x0.025” nickel-titanium and stainless steel archwires. The samples examined were: ClarityTM Advanced, and ClarityTM metal-reinforced, and VictoryTM series brackets. The RS at calculated moments of 1000 g-mm, 2000 g-mm, and 3000 g-mm was determined and compared between the various brackets. Descriptive measures and one-way analysis of variance were used to calculate means and statistical differences among the bracket types. Results: No significant difference in RS between the brackets was found on nickel-titanium arch wires. The ClarityTM Advanced bracket had significantly greater (P &lt; 0.05) RS than the other brackets tested at all three calculated moments on stainless steel archwires. Conclusion: ClarityTM Advanced brackets had significantly higher RS on stainless steel archwires.","abstract_has_math":false,"creators":["Ditch, Dustin"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-07","date_published":"2018-07","updated_at":"2026-11-19T08:39:07Z","subjects":["Clarity Advanced Ceramic Bracket","Resistance to Sliding"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ditch, Dustin. (2018). Comparison of Resistance to Sliding Between Metal Lined Ceramic Brackets and Unlined Ceramic Brackets: An In Vitro Study. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/200142."],"render_values":[{"text":"Ditch, Dustin. (2018). Comparison of Resistance to Sliding Between Metal Lined Ceramic Brackets and Unlined Ceramic Brackets: An In Vitro Study. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/200142.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11299/200142","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11299/200142","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F200142","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ditch, Dustin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-09-21T16:06:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-09-21T16:06:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-07"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Clarity Advanced Ceramic Bracket","Resistance to Sliding"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ditch, Dustin. (2018). Comparison of Resistance to Sliding Between Metal Lined Ceramic Brackets and Unlined Ceramic Brackets: An In Vitro Study. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/200142."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11299/200142"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. July 2018. Major: Dentistry. Advisor: Thorsten Gruenheid. 1 computer file (PDF); v, 54 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Objective: Comparing resistance to sliding (RS) between esthetic brackets under an increasing applied moment. Materials and Methods: Three different brackets were mounted on a testing apparatus to simulate canine retraction using sliding mechanics and application of a moment on 0.019”x0.025” nickel-titanium and stainless steel archwires. The samples examined were: ClarityTM Advanced, and ClarityTM metal-reinforced, and VictoryTM series brackets. The RS at calculated moments of 1000 g-mm, 2000 g-mm, and 3000 g-mm was determined and compared between the various brackets. Descriptive measures and one-way analysis of variance were used to calculate means and statistical differences among the bracket types. Results: No significant difference in RS between the brackets was found on nickel-titanium arch wires. The ClarityTM Advanced bracket had significantly greater (P < 0.05) RS than the other brackets tested at all three calculated moments on stainless steel archwires. Conclusion: ClarityTM Advanced brackets had significantly higher RS on stainless steel archwires."]},{"key":"dc:title","label":"Title","values":["Comparison of Resistance to Sliding Between Metal Lined Ceramic Brackets and Unlined Ceramic Brackets: An In Vitro Study"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Ditch, Dustin"],"dc:date.accessioned":["2018-09-21T16:06:05Z"],"dc:date.available":["2018-09-21T16:06:05Z"],"dc:date.issued":["2018-07"],"dc:description":["University of Minnesota M.S. thesis. July 2018. Major: Dentistry. Advisor: Thorsten Gruenheid. 1 computer file (PDF); v, 54 pages."],"dc:description.abstract":["Objective: Comparing resistance to sliding (RS) between esthetic brackets under an increasing applied moment. Materials and Methods: Three different brackets were mounted on a testing apparatus to simulate canine retraction using sliding mechanics and application of a moment on 0.019”x0.025” nickel-titanium and stainless steel archwires. The samples examined were: ClarityTM Advanced, and ClarityTM metal-reinforced, and VictoryTM series brackets. The RS at calculated moments of 1000 g-mm, 2000 g-mm, and 3000 g-mm was determined and compared between the various brackets. Descriptive measures and one-way analysis of variance were used to calculate means and statistical differences among the bracket types. Results: No significant difference in RS between the brackets was found on nickel-titanium arch wires. The ClarityTM Advanced bracket had significantly greater (P < 0.05) RS than the other brackets tested at all three calculated moments on stainless steel archwires. Conclusion: ClarityTM Advanced brackets had significantly higher RS on stainless steel archwires."],"dc:identifier.citation":["Ditch, Dustin. (2018). Comparison of Resistance to Sliding Between Metal Lined Ceramic Brackets and Unlined Ceramic Brackets: An In Vitro Study. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/200142."],"dc:identifier.uri":["http://hdl.handle.net/11299/200142"],"dc:language.iso":["en"],"dc:subject":["Clarity Advanced Ceramic Bracket","Resistance to Sliding"],"dc:title":["Comparison of Resistance to Sliding Between Metal Lined Ceramic Brackets and Unlined Ceramic Brackets: An In Vitro Study"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:39:07Z"}