{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/202893"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/202893","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"The Study of a Ferromagnetic Resonance Measurement System Characterizing Magnetic Nanowires","abstract":"This thesis discusses the characterization of ferromagnetic nanowires (MNWs) and their applications. Chapter 2 introduces the static and dynamic properties of the MNWs and provides an overview to the ferromagnetic resonance (FMR) measurement system. Chapter 3 focuses on the design of the measurement grounded coplanar waveguide (GCPW) circuit, along with the co-simulation of GCPW circuit and ferromagnetic nanowire array (MNWA). Chapter 4 describes the implementation of the VNA-FMR measurement system, including the frequency-sweep and the field-sweep approaches, and the optimization of measurement configurations. The applications of MNWs are demonstrated in two aspects, one in passive microwave device design and another in bio-labeling system design. Chapter 5 presents a MNWA based self-biased circulator at Ka band that has the potential for MMIC integration. Chapter 6 proposes a MNWs-based biolabeling system for multiple cancer cell type detection. An algorithm for multi-MNW type identification is discussed, and the development path from MNWAs to use as MNWs is explained.","abstract_html":"This thesis discusses the characterization of ferromagnetic nanowires (MNWs) and their applications. Chapter 2 introduces the static and dynamic properties of the MNWs and provides an overview to the ferromagnetic resonance (FMR) measurement system. Chapter 3 focuses on the design of the measurement grounded coplanar waveguide (GCPW) circuit, along with the co-simulation of GCPW circuit and ferromagnetic nanowire array (MNWA). Chapter 4 describes the implementation of the VNA-FMR measurement system, including the frequency-sweep and the field-sweep approaches, and the optimization of measurement configurations. The applications of MNWs are demonstrated in two aspects, one in passive microwave device design and another in bio-labeling system design. Chapter 5 presents a MNWA based self-biased circulator at Ka band that has the potential for MMIC integration. Chapter 6 proposes a MNWs-based biolabeling system for multiple cancer cell type detection. An algorithm for multi-MNW type identification is discussed, and the development path from MNWAs to use as MNWs is explained.","abstract_has_math":false,"creators":["Zhou, Wen"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-03","date_published":"2019-03","updated_at":"2026-11-19T09:50:06Z","subjects":["biolabeling system","circulator","ferromagnetic resonance","magnetic nanowire","material characterization"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zhou, Wen. (2019). The Study of a Ferromagnetic Resonance Measurement System Characterizing Magnetic Nanowires. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/202893."],"render_values":[{"text":"Zhou, Wen. (2019). The Study of a Ferromagnetic Resonance Measurement System Characterizing Magnetic Nanowires. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/202893.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11299/202893","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11299/202893","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F202893","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Zhou, Wen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-05-13T19:26:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-05-13T19:26:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-03"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["biolabeling system","circulator","ferromagnetic resonance","magnetic nanowire","material characterization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zhou, Wen. (2019). The Study of a Ferromagnetic Resonance Measurement System Characterizing Magnetic Nanowires. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/202893."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11299/202893"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S.E.E. thesis. 2019. Major: Electrical Engineering. Advisor: Rhonda Franklin. 1 computer file (PDF); 105 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis discusses the characterization of ferromagnetic nanowires (MNWs) and their applications. Chapter 2 introduces the static and dynamic properties of the MNWs and provides an overview to the ferromagnetic resonance (FMR) measurement system. Chapter 3 focuses on the design of the measurement grounded coplanar waveguide (GCPW) circuit, along with the co-simulation of GCPW circuit and ferromagnetic nanowire array (MNWA). Chapter 4 describes the implementation of the VNA-FMR measurement system, including the frequency-sweep and the field-sweep approaches, and the optimization of measurement configurations. The applications of MNWs are demonstrated in two aspects, one in passive microwave device design and another in bio-labeling system design. Chapter 5 presents a MNWA based self-biased circulator at Ka band that has the potential for MMIC integration. Chapter 6 proposes a MNWs-based biolabeling system for multiple cancer cell type detection. An algorithm for multi-MNW type identification is discussed, and the development path from MNWAs to use as MNWs is explained."]},{"key":"dc:title","label":"Title","values":["The Study of a Ferromagnetic Resonance Measurement System Characterizing Magnetic Nanowires"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Zhou, Wen"],"dc:date.accessioned":["2019-05-13T19:26:20Z"],"dc:date.available":["2019-05-13T19:26:20Z"],"dc:date.issued":["2019-03"],"dc:description":["University of Minnesota M.S.E.E. thesis. 2019. Major: Electrical Engineering. Advisor: Rhonda Franklin. 1 computer file (PDF); 105 pages."],"dc:description.abstract":["This thesis discusses the characterization of ferromagnetic nanowires (MNWs) and their applications. Chapter 2 introduces the static and dynamic properties of the MNWs and provides an overview to the ferromagnetic resonance (FMR) measurement system. Chapter 3 focuses on the design of the measurement grounded coplanar waveguide (GCPW) circuit, along with the co-simulation of GCPW circuit and ferromagnetic nanowire array (MNWA). Chapter 4 describes the implementation of the VNA-FMR measurement system, including the frequency-sweep and the field-sweep approaches, and the optimization of measurement configurations. The applications of MNWs are demonstrated in two aspects, one in passive microwave device design and another in bio-labeling system design. Chapter 5 presents a MNWA based self-biased circulator at Ka band that has the potential for MMIC integration. Chapter 6 proposes a MNWs-based biolabeling system for multiple cancer cell type detection. An algorithm for multi-MNW type identification is discussed, and the development path from MNWAs to use as MNWs is explained."],"dc:identifier.citation":["Zhou, Wen. (2019). The Study of a Ferromagnetic Resonance Measurement System Characterizing Magnetic Nanowires. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/202893."],"dc:identifier.uri":["http://hdl.handle.net/11299/202893"],"dc:language.iso":["en"],"dc:subject":["biolabeling system","circulator","ferromagnetic resonance","magnetic nanowire","material characterization"],"dc:title":["The Study of a Ferromagnetic Resonance Measurement System Characterizing Magnetic Nanowires"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:50:06Z"}