{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/208945"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/208945","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars","abstract":"Utilizing ground glass as a pozzolan in concrete could provide a high-value market for discarded glass, and help to reduce the amount of portland cement used, thereby reducing the CO2 emissions associated with the concrete mixture. 18 different waste glass sources from across the country were used to make mortars containing 20% and 30% portland cement replacement levels by mass. Compressive strength was measured through six months. The hardened air void structure was analyzed past six months. Most glasses met 75% Strength Activity Index at 7 and 28 days when a 20% replacement level was used. An increased replacement level of 30% resulted in lower compressive strength for all but E-glass. Glass composition was found to affect the compressive strength and hardened air void structure, though strength variation among glasses of the same type was found to be less than strength variation between different types of glass.","abstract_html":"Utilizing ground glass as a pozzolan in concrete could provide a high-value market for discarded glass, and help to reduce the amount of portland cement used, thereby reducing the CO2 emissions associated with the concrete mixture. 18 different waste glass sources from across the country were used to make mortars containing 20% and 30% portland cement replacement levels by mass. Compressive strength was measured through six months. The hardened air void structure was analyzed past six months. Most glasses met 75% Strength Activity Index at 7 and 28 days when a 20% replacement level was used. An increased replacement level of 30% resulted in lower compressive strength for all but E-glass. Glass composition was found to affect the compressive strength and hardened air void structure, though strength variation among glasses of the same type was found to be less than strength variation between different types of glass.","abstract_has_math":false,"creators":["Moore, Colton"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-08","date_published":"2019-08","updated_at":"2026-11-19T09:50:12Z","subjects":["Ground Glass","Mortar Cubes","Portland Cement","Pozzolans","Supplementary Cementitious Materials"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Moore, Colton. (2019). Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/208945."],"render_values":[{"text":"Moore, Colton. (2019). Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/208945.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11299/208945","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11299/208945","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F208945","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Moore, Colton"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-12-11T16:42:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-12-11T16:42:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ground Glass","Mortar Cubes","Portland Cement","Pozzolans","Supplementary Cementitious Materials"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Moore, Colton. (2019). Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/208945."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11299/208945"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. August 2019. Major: Civil Engineering. Advisor: Mary Christiansen. 1 computer file (PDF); xxiii, 215 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Utilizing ground glass as a pozzolan in concrete could provide a high-value market for discarded glass, and help to reduce the amount of portland cement used, thereby reducing the CO2 emissions associated with the concrete mixture. 18 different waste glass sources from across the country were used to make mortars containing 20% and 30% portland cement replacement levels by mass. Compressive strength was measured through six months. The hardened air void structure was analyzed past six months. Most glasses met 75% Strength Activity Index at 7 and 28 days when a 20% replacement level was used. An increased replacement level of 30% resulted in lower compressive strength for all but E-glass. Glass composition was found to affect the compressive strength and hardened air void structure, though strength variation among glasses of the same type was found to be less than strength variation between different types of glass."]},{"key":"dc:title","label":"Title","values":["Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Moore, Colton"],"dc:date.accessioned":["2019-12-11T16:42:49Z"],"dc:date.available":["2019-12-11T16:42:49Z"],"dc:date.issued":["2019-08"],"dc:description":["University of Minnesota M.S. thesis. August 2019. Major: Civil Engineering. Advisor: Mary Christiansen. 1 computer file (PDF); xxiii, 215 pages."],"dc:description.abstract":["Utilizing ground glass as a pozzolan in concrete could provide a high-value market for discarded glass, and help to reduce the amount of portland cement used, thereby reducing the CO2 emissions associated with the concrete mixture. 18 different waste glass sources from across the country were used to make mortars containing 20% and 30% portland cement replacement levels by mass. Compressive strength was measured through six months. The hardened air void structure was analyzed past six months. Most glasses met 75% Strength Activity Index at 7 and 28 days when a 20% replacement level was used. An increased replacement level of 30% resulted in lower compressive strength for all but E-glass. Glass composition was found to affect the compressive strength and hardened air void structure, though strength variation among glasses of the same type was found to be less than strength variation between different types of glass."],"dc:identifier.citation":["Moore, Colton. (2019). Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/208945."],"dc:identifier.uri":["http://hdl.handle.net/11299/208945"],"dc:language.iso":["en"],"dc:subject":["Ground Glass","Mortar Cubes","Portland Cement","Pozzolans","Supplementary Cementitious Materials"],"dc:title":["Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:50:12Z"}