{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/224494"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/224494","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Transfer Accuracy of 3D-Printed Trays for Indirect Bonding of Orthodontic Brackets: A Clinical Study","abstract":"Aim: To evaluate the transfer accuracy of 3D-printed indirect bonding trays constructed using a fully digital workflow in a clinical setting.Methods: Twenty-three consecutive patients had their incisors, canines, and premolars bonded using a fully digital indirect bonding method and 3D-printed transfer trays. Intraoral scans were taken to capture the final bracket positioning on the teeth following bonding. Digital models of the post-bonding scans were superimposed on those of the corresponding virtual bracket setups, and bracket positioning differences were quantified. A total of 363 brackets were evaluated. One tailed t-tests were used to determine whether bracket positioning differences were within limits of 0.5 mm in the mesio-distal, bucco-lingual, and occluso-gingival dimensions, and within 2° for torque, tip, and rotation. Results: Mean bracket positioning differences were 0.10 mm, 0.10 mm, and 0.18 mm for mesio-distal, bucco-lingual, and occluso-gingival measurements, respectively. For the linear dimensions, frequencies of bracket positioning error within the 0.5-mm limit ranged from 96.4–100%. Mean differences were significantly within the acceptable range for these dimensions. Mean differences were 2.55°, 2.01°, and 2.47° for torque, tip, and rotation, respectively. For the angular measurements, frequencies within the 2°-limit ranged from 46.0–57.0%. The mean differences for the angular dimensions were outside the acceptable limit; however, this may have been due to limitations of the scan data. Conclusions: Indirect bonding using 3D-printed trays transfers the planned bracket position from the digital setup to the patient’s dentition with a high positional accuracy in the mesio-distal, bucco-lingual, and occluso-gingival dimensions. Questions remain regarding the transfer accuracy in the angular dimensions.","abstract_html":"Aim: To evaluate the transfer accuracy of 3D-printed indirect bonding trays constructed using a fully digital workflow in a clinical setting.Methods: Twenty-three consecutive patients had their incisors, canines, and premolars bonded using a fully digital indirect bonding method and 3D-printed transfer trays. Intraoral scans were taken to capture the final bracket positioning on the teeth following bonding. Digital models of the post-bonding scans were superimposed on those of the corresponding virtual bracket setups, and bracket positioning differences were quantified. A total of 363 brackets were evaluated. One tailed t-tests were used to determine whether bracket positioning differences were within limits of 0.5 mm in the mesio-distal, bucco-lingual, and occluso-gingival dimensions, and within 2° for torque, tip, and rotation. Results: Mean bracket positioning differences were 0.10 mm, 0.10 mm, and 0.18 mm for mesio-distal, bucco-lingual, and occluso-gingival measurements, respectively. For the linear dimensions, frequencies of bracket positioning error within the 0.5-mm limit ranged from 96.4–100%. Mean differences were significantly within the acceptable range for these dimensions. Mean differences were 2.55°, 2.01°, and 2.47° for torque, tip, and rotation, respectively. For the angular measurements, frequencies within the 2°-limit ranged from 46.0–57.0%. The mean differences for the angular dimensions were outside the acceptable limit; however, this may have been due to limitations of the scan data. Conclusions: Indirect bonding using 3D-printed trays transfers the planned bracket position from the digital setup to the patient’s dentition with a high positional accuracy in the mesio-distal, bucco-lingual, and occluso-gingival dimensions. Questions remain regarding the transfer accuracy in the angular dimensions.","abstract_has_math":false,"creators":["Bachour, Petra"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-06","date_published":"2021-06","updated_at":"2026-11-19T09:50:43Z","subjects":["3D-printing","Indirect Bonding","Orthodontics"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Bachour, Petra. (2021). Transfer Accuracy of 3D-Printed Trays for Indirect Bonding of Orthodontic Brackets: A Clinical Study. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/224494."],"render_values":[{"text":"Bachour, Petra. (2021). Transfer Accuracy of 3D-Printed Trays for Indirect Bonding of Orthodontic Brackets: A Clinical Study. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/224494.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/224494","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/224494","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F224494","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F224494","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bachour, Petra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-09-24T15:57:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-09-24T15:57:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2021-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["3D-printing","Indirect Bonding","Orthodontics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Bachour, Petra. (2021). Transfer Accuracy of 3D-Printed Trays for Indirect Bonding of Orthodontic Brackets: A Clinical Study. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/224494."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/224494"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis.June 2021. Major: Dentistry. Advisor: Thorsten Grünheid. 1 computer file (PDF); vi, 51 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Aim: To evaluate the transfer accuracy of 3D-printed indirect bonding trays constructed using a fully digital workflow in a clinical setting.Methods: Twenty-three consecutive patients had their incisors, canines, and premolars bonded using a fully digital indirect bonding method and 3D-printed transfer trays. Intraoral scans were taken to capture the final bracket positioning on the teeth following bonding. Digital models of the post-bonding scans were superimposed on those of the corresponding virtual bracket setups, and bracket positioning differences were quantified. A total of 363 brackets were evaluated. One tailed t-tests were used to determine whether bracket positioning differences were within limits of 0.5 mm in the mesio-distal, bucco-lingual, and occluso-gingival dimensions, and within 2° for torque, tip, and rotation. Results: Mean bracket positioning differences were 0.10 mm, 0.10 mm, and 0.18 mm for mesio-distal, bucco-lingual, and occluso-gingival measurements, respectively. For the linear dimensions, frequencies of bracket positioning error within the 0.5-mm limit ranged from 96.4–100%. Mean differences were significantly within the acceptable range for these dimensions. Mean differences were 2.55°, 2.01°, and 2.47° for torque, tip, and rotation, respectively. For the angular measurements, frequencies within the 2°-limit ranged from 46.0–57.0%. The mean differences for the angular dimensions were outside the acceptable limit; however, this may have been due to limitations of the scan data. Conclusions: Indirect bonding using 3D-printed trays transfers the planned bracket position from the digital setup to the patient’s dentition with a high positional accuracy in the mesio-distal, bucco-lingual, and occluso-gingival dimensions. Questions remain regarding the transfer accuracy in the angular dimensions."]},{"key":"dc:title","label":"Title","values":["Transfer Accuracy of 3D-Printed Trays for Indirect Bonding of Orthodontic Brackets: A Clinical Study"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Bachour, Petra"],"dc:date.accessioned":["2021-09-24T15:57:49Z"],"dc:date.available":["2021-09-24T15:57:49Z"],"dc:date.issued":["2021-06"],"dc:description":["University of Minnesota M.S. thesis.June 2021. Major: Dentistry. Advisor: Thorsten Grünheid. 1 computer file (PDF); vi, 51 pages."],"dc:description.abstract":["Aim: To evaluate the transfer accuracy of 3D-printed indirect bonding trays constructed using a fully digital workflow in a clinical setting.Methods: Twenty-three consecutive patients had their incisors, canines, and premolars bonded using a fully digital indirect bonding method and 3D-printed transfer trays. Intraoral scans were taken to capture the final bracket positioning on the teeth following bonding. Digital models of the post-bonding scans were superimposed on those of the corresponding virtual bracket setups, and bracket positioning differences were quantified. A total of 363 brackets were evaluated. One tailed t-tests were used to determine whether bracket positioning differences were within limits of 0.5 mm in the mesio-distal, bucco-lingual, and occluso-gingival dimensions, and within 2° for torque, tip, and rotation. Results: Mean bracket positioning differences were 0.10 mm, 0.10 mm, and 0.18 mm for mesio-distal, bucco-lingual, and occluso-gingival measurements, respectively. For the linear dimensions, frequencies of bracket positioning error within the 0.5-mm limit ranged from 96.4–100%. Mean differences were significantly within the acceptable range for these dimensions. Mean differences were 2.55°, 2.01°, and 2.47° for torque, tip, and rotation, respectively. For the angular measurements, frequencies within the 2°-limit ranged from 46.0–57.0%. The mean differences for the angular dimensions were outside the acceptable limit; however, this may have been due to limitations of the scan data. Conclusions: Indirect bonding using 3D-printed trays transfers the planned bracket position from the digital setup to the patient’s dentition with a high positional accuracy in the mesio-distal, bucco-lingual, and occluso-gingival dimensions. Questions remain regarding the transfer accuracy in the angular dimensions."],"dc:identifier.citation":["Bachour, Petra. (2021). Transfer Accuracy of 3D-Printed Trays for Indirect Bonding of Orthodontic Brackets: A Clinical Study. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/224494."],"dc:identifier.uri":["https://hdl.handle.net/11299/224494"],"dc:language.iso":["en"],"dc:subject":["3D-printing","Indirect Bonding","Orthodontics"],"dc:title":["Transfer Accuracy of 3D-Printed Trays for Indirect Bonding of Orthodontic Brackets: A Clinical Study"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:50:43Z"}