{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/226347"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/226347","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete","abstract":"Post-installed reinforcing bars are frequently used to connect new concrete members to an existing structure. In these applications, uncoated steel reinforcing bars are often used, which are susceptible to corrosion. The use of glass fiber-reinforced polymer (GFRP) reinforcing bars in structural concrete has increased in recent years due to many factors, including their noncorrosive and nonconductive nature, high tensile strength, and nonmagnetic properties. Currently, structural concrete design using GFRP reinforcing bars is covered in ACI 440.1R, which does not include provisions for anchorage to concrete. This research was conducted to begin filling that knowledge gap and determine if the equations for anchorage to concrete with steel reinforcing bars given in ACI 318 are appropriate for use with GFRP reinforcing bars. A series of tests were conducted with tensile and shear loading to characterize behavior of post-installed GFRP reinforcing bars and allow for comparison of their behavior to post-installed steel reinforcing bars. Specifically, two sizes of both steel and GFRP reinforcing bars (No. 5 and 8) were post-installed in concrete slabs using the same chemical adhesive. The confined and unconfined tensile strength of the bars away from concrete edges and in proximity to concrete edges was established. Additionally, shear tests on No. 5 bars were performed. Using the information gathered from these tests, the applicability of ACI 318 design guidelines for post-installed GFRP reinforcing bars is presented.","abstract_html":"Post-installed reinforcing bars are frequently used to connect new concrete members to an existing structure. In these applications, uncoated steel reinforcing bars are often used, which are susceptible to corrosion. The use of glass fiber-reinforced polymer (GFRP) reinforcing bars in structural concrete has increased in recent years due to many factors, including their noncorrosive and nonconductive nature, high tensile strength, and nonmagnetic properties. Currently, structural concrete design using GFRP reinforcing bars is covered in ACI 440.1R, which does not include provisions for anchorage to concrete. This research was conducted to begin filling that knowledge gap and determine if the equations for anchorage to concrete with steel reinforcing bars given in ACI 318 are appropriate for use with GFRP reinforcing bars. A series of tests were conducted with tensile and shear loading to characterize behavior of post-installed GFRP reinforcing bars and allow for comparison of their behavior to post-installed steel reinforcing bars. Specifically, two sizes of both steel and GFRP reinforcing bars (No. 5 and 8) were post-installed in concrete slabs using the same chemical adhesive. The confined and unconfined tensile strength of the bars away from concrete edges and in proximity to concrete edges was established. Additionally, shear tests on No. 5 bars were performed. Using the information gathered from these tests, the applicability of ACI 318 design guidelines for post-installed GFRP reinforcing bars is presented.","abstract_has_math":false,"creators":["DeMars, Thomas"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-12","date_published":"2021-12","updated_at":"2026-11-19T09:50:51Z","subjects":["Department of Civil Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Civil Engineering"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["DeMars, Thomas. (2021). Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/226347."],"render_values":[{"text":"DeMars, Thomas. (2021). Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/226347.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/226347","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/226347","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F226347","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F226347","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["DeMars, Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-02-15T20:13:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-02-15T20:13:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2021-12"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Department of Civil Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Civil Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["DeMars, Thomas. (2021). Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/226347."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/226347"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. December 2021. Major: Civil Engineering. Advisor: Benjamin Dymond. 1 computer file (PDF); xii, 199 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Post-installed reinforcing bars are frequently used to connect new concrete members to an existing structure. In these applications, uncoated steel reinforcing bars are often used, which are susceptible to corrosion. The use of glass fiber-reinforced polymer (GFRP) reinforcing bars in structural concrete has increased in recent years due to many factors, including their noncorrosive and nonconductive nature, high tensile strength, and nonmagnetic properties. Currently, structural concrete design using GFRP reinforcing bars is covered in ACI 440.1R, which does not include provisions for anchorage to concrete. This research was conducted to begin filling that knowledge gap and determine if the equations for anchorage to concrete with steel reinforcing bars given in ACI 318 are appropriate for use with GFRP reinforcing bars. A series of tests were conducted with tensile and shear loading to characterize behavior of post-installed GFRP reinforcing bars and allow for comparison of their behavior to post-installed steel reinforcing bars. Specifically, two sizes of both steel and GFRP reinforcing bars (No. 5 and 8) were post-installed in concrete slabs using the same chemical adhesive. The confined and unconfined tensile strength of the bars away from concrete edges and in proximity to concrete edges was established. Additionally, shear tests on No. 5 bars were performed. Using the information gathered from these tests, the applicability of ACI 318 design guidelines for post-installed GFRP reinforcing bars is presented."]},{"key":"dc:title","label":"Title","values":["Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["DeMars, Thomas"],"dc:date.accessioned":["2022-02-15T20:13:20Z"],"dc:date.available":["2022-02-15T20:13:20Z"],"dc:date.issued":["2021-12"],"dc:description":["University of Minnesota M.S. thesis. December 2021. Major: Civil Engineering. Advisor: Benjamin Dymond. 1 computer file (PDF); xii, 199 pages."],"dc:description.abstract":["Post-installed reinforcing bars are frequently used to connect new concrete members to an existing structure. In these applications, uncoated steel reinforcing bars are often used, which are susceptible to corrosion. The use of glass fiber-reinforced polymer (GFRP) reinforcing bars in structural concrete has increased in recent years due to many factors, including their noncorrosive and nonconductive nature, high tensile strength, and nonmagnetic properties. Currently, structural concrete design using GFRP reinforcing bars is covered in ACI 440.1R, which does not include provisions for anchorage to concrete. This research was conducted to begin filling that knowledge gap and determine if the equations for anchorage to concrete with steel reinforcing bars given in ACI 318 are appropriate for use with GFRP reinforcing bars. A series of tests were conducted with tensile and shear loading to characterize behavior of post-installed GFRP reinforcing bars and allow for comparison of their behavior to post-installed steel reinforcing bars. Specifically, two sizes of both steel and GFRP reinforcing bars (No. 5 and 8) were post-installed in concrete slabs using the same chemical adhesive. The confined and unconfined tensile strength of the bars away from concrete edges and in proximity to concrete edges was established. Additionally, shear tests on No. 5 bars were performed. Using the information gathered from these tests, the applicability of ACI 318 design guidelines for post-installed GFRP reinforcing bars is presented."],"dc:identifier.citation":["DeMars, Thomas. (2021). Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/226347."],"dc:identifier.uri":["https://hdl.handle.net/11299/226347"],"dc:language.iso":["en"],"dc:subject":["Department of Civil Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Civil Engineering"],"dc:title":["Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:50:51Z"}