{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/243174"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/243174","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"The Non-Invasive Application of Electrocardiography in the Optimization of Cardiac Resynchronization Therapy","abstract":"Cardiac resynchronization therapy (CRT) is intended to reverse electrical dyssynchrony and improve systolic function in heart failure patients. However, roughly 30% of recipients do not clinically or echocardiography benefit, despite advancements with implant techniques and pacing technology, and are considered to be non-responders (Auricchio & Prinzen, 2011). Suboptimal postoperative device programming of the interventricular and atrioventricular delays, and the left ventricular (LV) pacing vector in quadripolar leads, is thought to be a prevailing cause of this persistent non-response (Mullens et al., 2009). Device optimization of pacing configurations is highly underutilized, and research has yet to establish a standardized, patient-specific methodology that can be routinely used in outpatient heart failure clinics (Gras, Gupta, Boulogne, Guzzo, & Abraham, 2009; N. Varma et al., 2019). The use of electrocardiography in device optimization is supported by the notion that synchronous ventricular electrical activation is a requisite for adequate systolic and diastolic function (Nguyen, Verzaal, van Nieuwenhoven, Vernooy, & Prinzen, 2018). Electrocardiography has furthermore shown promise in routine CRT device optimization owning to its non-invasive, inexpensive, and practical attributes. QRS duration shortening during the paced rhythm, as well as metrics of wavefront fusion and cancellation, on 12-lead electrocardiograms have been reported to correlate with subsequent LV reverse remodeling (Gage et al., 2018; Sweeney et al., 2014; Sweeney et al., 2010). Innovations in technology allow for the application of multiple unipolar electrodes placed over the upper anterior and posterior torso (Bank et al., 2018; Johnson et al., 2017; Rickard et al., 2020). The intent of this technology, as depicted in its ability to simultaneously acquire ventricular activation from both anterior and posterior surfaces, is to provide a better assessment of electrical dyssynchrony relative to that of a 12-lead electrocardiogram. Previous reports have shown that this technology can accurately, non-invasively, and efficiently measure electrical heterogeneity in patients with CRT devices (Gage et al., 2017). The purpose of this dissertation is to use this technology to: (1) quantify how a device-based pacing algorithm improves electrical resynchronization, and (2) evaluate the therapeutic window on the corresponding potential of electrical resynchronization during left ventricular unipolar pacing.","abstract_html":"Cardiac resynchronization therapy (CRT) is intended to reverse electrical dyssynchrony and improve systolic function in heart failure patients. However, roughly 30% of recipients do not clinically or echocardiography benefit, despite advancements with implant techniques and pacing technology, and are considered to be non-responders (Auricchio &amp; Prinzen, 2011). Suboptimal postoperative device programming of the interventricular and atrioventricular delays, and the left ventricular (LV) pacing vector in quadripolar leads, is thought to be a prevailing cause of this persistent non-response (Mullens et al., 2009). Device optimization of pacing configurations is highly underutilized, and research has yet to establish a standardized, patient-specific methodology that can be routinely used in outpatient heart failure clinics (Gras, Gupta, Boulogne, Guzzo, &amp; Abraham, 2009; N. Varma et al., 2019). The use of electrocardiography in device optimization is supported by the notion that synchronous ventricular electrical activation is a requisite for adequate systolic and diastolic function (Nguyen, Verzaal, van Nieuwenhoven, Vernooy, &amp; Prinzen, 2018). Electrocardiography has furthermore shown promise in routine CRT device optimization owning to its non-invasive, inexpensive, and practical attributes. QRS duration shortening during the paced rhythm, as well as metrics of wavefront fusion and cancellation, on 12-lead electrocardiograms have been reported to correlate with subsequent LV reverse remodeling (Gage et al., 2018; Sweeney et al., 2014; Sweeney et al., 2010). Innovations in technology allow for the application of multiple unipolar electrodes placed over the upper anterior and posterior torso (Bank et al., 2018; Johnson et al., 2017; Rickard et al., 2020). The intent of this technology, as depicted in its ability to simultaneously acquire ventricular activation from both anterior and posterior surfaces, is to provide a better assessment of electrical dyssynchrony relative to that of a 12-lead electrocardiogram. Previous reports have shown that this technology can accurately, non-invasively, and efficiently measure electrical heterogeneity in patients with CRT devices (Gage et al., 2017). The purpose of this dissertation is to use this technology to: (1) quantify how a device-based pacing algorithm improves electrical resynchronization, and (2) evaluate the therapeutic window on the corresponding potential of electrical resynchronization during left ventricular unipolar pacing.","abstract_has_math":false,"creators":["Harbin, Michelle"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-08","date_published":"2020-08","updated_at":"2026-11-19T09:51:04Z","subjects":["Cardiac resynchronization therapy","Electrical dyssynchrony","Electrocardiography","Heart failure","Left bundle branch block"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Harbin, Michelle. (2020). The Non-Invasive Application of Electrocardiography in the Optimization of Cardiac Resynchronization Therapy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/243174."],"render_values":[{"text":"Harbin, Michelle. (2020). The Non-Invasive Application of Electrocardiography in the Optimization of Cardiac Resynchronization Therapy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/243174.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/243174","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/243174","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F243174","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Harbin, Michelle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-11-14T12:38:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-11-14T12:38:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2020-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Cardiac resynchronization therapy","Electrical dyssynchrony","Electrocardiography","Heart failure","Left bundle branch block"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Harbin, Michelle. (2020). The Non-Invasive Application of Electrocardiography in the Optimization of Cardiac Resynchronization Therapy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/243174."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/243174"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota Ph.D. dissertation. 2020. Major: Kinesiology. Advisor: Donald Dengel. 1 computer file (PDF); 153 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Cardiac resynchronization therapy (CRT) is intended to reverse electrical dyssynchrony and improve systolic function in heart failure patients. However, roughly 30% of recipients do not clinically or echocardiography benefit, despite advancements with implant techniques and pacing technology, and are considered to be non-responders (Auricchio & Prinzen, 2011). Suboptimal postoperative device programming of the interventricular and atrioventricular delays, and the left ventricular (LV) pacing vector in quadripolar leads, is thought to be a prevailing cause of this persistent non-response (Mullens et al., 2009). Device optimization of pacing configurations is highly underutilized, and research has yet to establish a standardized, patient-specific methodology that can be routinely used in outpatient heart failure clinics (Gras, Gupta, Boulogne, Guzzo, & Abraham, 2009; N. Varma et al., 2019). The use of electrocardiography in device optimization is supported by the notion that synchronous ventricular electrical activation is a requisite for adequate systolic and diastolic function (Nguyen, Verzaal, van Nieuwenhoven, Vernooy, & Prinzen, 2018). Electrocardiography has furthermore shown promise in routine CRT device optimization owning to its non-invasive, inexpensive, and practical attributes. QRS duration shortening during the paced rhythm, as well as metrics of wavefront fusion and cancellation, on 12-lead electrocardiograms have been reported to correlate with subsequent LV reverse remodeling (Gage et al., 2018; Sweeney et al., 2014; Sweeney et al., 2010). Innovations in technology allow for the application of multiple unipolar electrodes placed over the upper anterior and posterior torso (Bank et al., 2018; Johnson et al., 2017; Rickard et al., 2020). The intent of this technology, as depicted in its ability to simultaneously acquire ventricular activation from both anterior and posterior surfaces, is to provide a better assessment of electrical dyssynchrony relative to that of a 12-lead electrocardiogram. Previous reports have shown that this technology can accurately, non-invasively, and efficiently measure electrical heterogeneity in patients with CRT devices (Gage et al., 2017). The purpose of this dissertation is to use this technology to: (1) quantify how a device-based pacing algorithm improves electrical resynchronization, and (2) evaluate the therapeutic window on the corresponding potential of electrical resynchronization during left ventricular unipolar pacing."]},{"key":"dc:title","label":"Title","values":["The Non-Invasive Application of Electrocardiography in the Optimization of Cardiac Resynchronization Therapy"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Harbin, Michelle"],"dc:date.accessioned":["2022-11-14T12:38:49Z"],"dc:date.available":["2022-11-14T12:38:49Z"],"dc:date.issued":["2020-08"],"dc:description":["University of Minnesota Ph.D. dissertation. 2020. Major: Kinesiology. Advisor: Donald Dengel. 1 computer file (PDF); 153 pages."],"dc:description.abstract":["Cardiac resynchronization therapy (CRT) is intended to reverse electrical dyssynchrony and improve systolic function in heart failure patients. However, roughly 30% of recipients do not clinically or echocardiography benefit, despite advancements with implant techniques and pacing technology, and are considered to be non-responders (Auricchio & Prinzen, 2011). Suboptimal postoperative device programming of the interventricular and atrioventricular delays, and the left ventricular (LV) pacing vector in quadripolar leads, is thought to be a prevailing cause of this persistent non-response (Mullens et al., 2009). Device optimization of pacing configurations is highly underutilized, and research has yet to establish a standardized, patient-specific methodology that can be routinely used in outpatient heart failure clinics (Gras, Gupta, Boulogne, Guzzo, & Abraham, 2009; N. Varma et al., 2019). The use of electrocardiography in device optimization is supported by the notion that synchronous ventricular electrical activation is a requisite for adequate systolic and diastolic function (Nguyen, Verzaal, van Nieuwenhoven, Vernooy, & Prinzen, 2018). Electrocardiography has furthermore shown promise in routine CRT device optimization owning to its non-invasive, inexpensive, and practical attributes. QRS duration shortening during the paced rhythm, as well as metrics of wavefront fusion and cancellation, on 12-lead electrocardiograms have been reported to correlate with subsequent LV reverse remodeling (Gage et al., 2018; Sweeney et al., 2014; Sweeney et al., 2010). Innovations in technology allow for the application of multiple unipolar electrodes placed over the upper anterior and posterior torso (Bank et al., 2018; Johnson et al., 2017; Rickard et al., 2020). The intent of this technology, as depicted in its ability to simultaneously acquire ventricular activation from both anterior and posterior surfaces, is to provide a better assessment of electrical dyssynchrony relative to that of a 12-lead electrocardiogram. Previous reports have shown that this technology can accurately, non-invasively, and efficiently measure electrical heterogeneity in patients with CRT devices (Gage et al., 2017). The purpose of this dissertation is to use this technology to: (1) quantify how a device-based pacing algorithm improves electrical resynchronization, and (2) evaluate the therapeutic window on the corresponding potential of electrical resynchronization during left ventricular unipolar pacing."],"dc:identifier.citation":["Harbin, Michelle. (2020). The Non-Invasive Application of Electrocardiography in the Optimization of Cardiac Resynchronization Therapy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/243174."],"dc:identifier.uri":["https://hdl.handle.net/11299/243174"],"dc:language.iso":["en"],"dc:subject":["Cardiac resynchronization therapy","Electrical dyssynchrony","Electrocardiography","Heart failure","Left bundle branch block"],"dc:title":["The Non-Invasive Application of Electrocardiography in the Optimization of Cardiac Resynchronization Therapy"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:51:04Z"}