{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/259544"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/259544","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Embedded Plate Connection Between Hollow-Core Slabs and Concrete Walls","abstract":"In current practice, hollow-core slabs are connected to the top of cast-in-place walls using dowel or welded connections. The existing research on these connections is minimal, and their design capacity is limited, which created the need for a new connection that has a more efficient installation and an increased design capacity. This research project investigated a new slab-to-wall connection that consisted of an embedded steel plate and stud in the hollow-core. The capacity of the plate assembly embedded in a hollow-core slab was established by directly loading the assembly until steel or concrete failure. Proof-of-concept subassembly testing was conducted on hollow-core slabs connected to cast-in-place walls; the setup mimicked assembly at a jobsite. Capacity of the subassembly was established by applying load until the hollow-core slab, wall, or anchor failed. Results indicated that the embedded steel plate plus stud connection had a capacity that ranged from 8.6 to 33.5 kips when load was applied in various directions. The subassembly results indicated that the wall typically failed first, when subjected to applied loads that ranged from 2.5 to 19.8 kips. These results indicated that the proposed embedded steel plate and stud connection was robust enough for use in real-world applications.","abstract_html":"In current practice, hollow-core slabs are connected to the top of cast-in-place walls using dowel or welded connections. The existing research on these connections is minimal, and their design capacity is limited, which created the need for a new connection that has a more efficient installation and an increased design capacity. This research project investigated a new slab-to-wall connection that consisted of an embedded steel plate and stud in the hollow-core. The capacity of the plate assembly embedded in a hollow-core slab was established by directly loading the assembly until steel or concrete failure. Proof-of-concept subassembly testing was conducted on hollow-core slabs connected to cast-in-place walls; the setup mimicked assembly at a jobsite. Capacity of the subassembly was established by applying load until the hollow-core slab, wall, or anchor failed. Results indicated that the embedded steel plate plus stud connection had a capacity that ranged from 8.6 to 33.5 kips when load was applied in various directions. The subassembly results indicated that the wall typically failed first, when subjected to applied loads that ranged from 2.5 to 19.8 kips. These results indicated that the proposed embedded steel plate and stud connection was robust enough for use in real-world applications.","abstract_has_math":false,"creators":["Jackman, Kal"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-08","date_published":"2023-08","updated_at":"2026-11-19T09:51:44Z","subjects":["concrete","connections","hollow-core","precast","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Civil Engineering","Department of Civil Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Jackman, Kal. (2023). Embedded Plate Connection Between Hollow-Core Slabs and Concrete Walls. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/259544."],"render_values":[{"text":"Jackman, Kal. (2023). Embedded Plate Connection Between Hollow-Core Slabs and Concrete Walls. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/259544.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/259544","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/259544","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F259544","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Jackman, Kal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-05T18:56:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-05T18:56:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["concrete","connections","hollow-core","precast","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Civil Engineering","Department of Civil Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Jackman, Kal. (2023). Embedded Plate Connection Between Hollow-Core Slabs and Concrete Walls. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/259544."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/259544"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. August 2023. Major: Civil Engineering. Advisor: Brock Hedegaard. 1 computer file (PDF); v, 138 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["In current practice, hollow-core slabs are connected to the top of cast-in-place walls using dowel or welded connections. The existing research on these connections is minimal, and their design capacity is limited, which created the need for a new connection that has a more efficient installation and an increased design capacity. This research project investigated a new slab-to-wall connection that consisted of an embedded steel plate and stud in the hollow-core. The capacity of the plate assembly embedded in a hollow-core slab was established by directly loading the assembly until steel or concrete failure. Proof-of-concept subassembly testing was conducted on hollow-core slabs connected to cast-in-place walls; the setup mimicked assembly at a jobsite. Capacity of the subassembly was established by applying load until the hollow-core slab, wall, or anchor failed. Results indicated that the embedded steel plate plus stud connection had a capacity that ranged from 8.6 to 33.5 kips when load was applied in various directions. The subassembly results indicated that the wall typically failed first, when subjected to applied loads that ranged from 2.5 to 19.8 kips. These results indicated that the proposed embedded steel plate and stud connection was robust enough for use in real-world applications."]},{"key":"dc:title","label":"Title","values":["Embedded Plate Connection Between Hollow-Core Slabs and Concrete Walls"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Jackman, Kal"],"dc:date.accessioned":["2024-01-05T18:56:17Z"],"dc:date.available":["2024-01-05T18:56:17Z"],"dc:date.issued":["2023-08"],"dc:description":["University of Minnesota M.S. thesis. August 2023. Major: Civil Engineering. Advisor: Brock Hedegaard. 1 computer file (PDF); v, 138 pages."],"dc:description.abstract":["In current practice, hollow-core slabs are connected to the top of cast-in-place walls using dowel or welded connections. The existing research on these connections is minimal, and their design capacity is limited, which created the need for a new connection that has a more efficient installation and an increased design capacity. This research project investigated a new slab-to-wall connection that consisted of an embedded steel plate and stud in the hollow-core. The capacity of the plate assembly embedded in a hollow-core slab was established by directly loading the assembly until steel or concrete failure. Proof-of-concept subassembly testing was conducted on hollow-core slabs connected to cast-in-place walls; the setup mimicked assembly at a jobsite. Capacity of the subassembly was established by applying load until the hollow-core slab, wall, or anchor failed. Results indicated that the embedded steel plate plus stud connection had a capacity that ranged from 8.6 to 33.5 kips when load was applied in various directions. The subassembly results indicated that the wall typically failed first, when subjected to applied loads that ranged from 2.5 to 19.8 kips. These results indicated that the proposed embedded steel plate and stud connection was robust enough for use in real-world applications."],"dc:identifier.citation":["Jackman, Kal. (2023). Embedded Plate Connection Between Hollow-Core Slabs and Concrete Walls. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/259544."],"dc:identifier.uri":["https://hdl.handle.net/11299/259544"],"dc:language.iso":["en"],"dc:subject":["concrete","connections","hollow-core","precast","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Civil Engineering","Department of Civil Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth"],"dc:title":["Embedded Plate Connection Between Hollow-Core Slabs and Concrete Walls"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:51:44Z"}