{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/261980"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/261980","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Low-Cost Improvements in Pollution Monitoring Methods","abstract":"Pollution research and mitigation efforts rely on the accuracy of data collected by monitoring programs. I present work on improving monitoring protocols for two important pollutants. As a step towards improving the spatiotemporal resolution and lowering the cost of ground-level methane sensing, I design and thoroughly characterize an inexpensive sensor node for near-atmospheric methane monitoring. In an effort to improve stormwater monitoring methods, I develop a new model for runoff pollution and use it to simulate stormwater sampling, resulting in two suggested protocol modifications with the potential to substantially improve accuracy without increased cost. Throughout, I focus in particular on developing devices and methods that will improve monitoring accuracy or increase monitoring resolution at the same or lower cost as current approaches.","abstract_html":"Pollution research and mitigation efforts rely on the accuracy of data collected by monitoring programs. I present work on improving monitoring protocols for two important pollutants. As a step towards improving the spatiotemporal resolution and lowering the cost of ground-level methane sensing, I design and thoroughly characterize an inexpensive sensor node for near-atmospheric methane monitoring. In an effort to improve stormwater monitoring methods, I develop a new model for runoff pollution and use it to simulate stormwater sampling, resulting in two suggested protocol modifications with the potential to substantially improve accuracy without increased cost. Throughout, I focus in particular on developing devices and methods that will improve monitoring accuracy or increase monitoring resolution at the same or lower cost as current approaches.","abstract_has_math":false,"creators":["Furuta, Daniel"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T09:51:44Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Furuta, Daniel. (2024). Low-Cost Improvements in Pollution Monitoring Methods. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/261980."],"render_values":[{"text":"Furuta, Daniel. (2024). Low-Cost Improvements in Pollution Monitoring Methods. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/261980.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/261980","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/261980","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F261980","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F261980","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Furuta, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-03-29T13:26:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-03-29T13:26:35Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Furuta, Daniel. (2024). Low-Cost Improvements in Pollution Monitoring Methods. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/261980."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/261980"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota Ph.D. dissertation.--- 2024. Major: Biosystems and Agricultural Engineering. Advisor: Bruce Wilson. 1 computer file (PDF); vi, 102 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Pollution research and mitigation efforts rely on the accuracy of data collected by monitoring programs. I present work on improving monitoring protocols for two important pollutants. As a step towards improving the spatiotemporal resolution and lowering the cost of ground-level methane sensing, I design and thoroughly characterize an inexpensive sensor node for near-atmospheric methane monitoring. In an effort to improve stormwater monitoring methods, I develop a new model for runoff pollution and use it to simulate stormwater sampling, resulting in two suggested protocol modifications with the potential to substantially improve accuracy without increased cost. Throughout, I focus in particular on developing devices and methods that will improve monitoring accuracy or increase monitoring resolution at the same or lower cost as current approaches."]},{"key":"dc:title","label":"Title","values":["Low-Cost Improvements in Pollution Monitoring Methods"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Furuta, Daniel"],"dc:date.accessioned":["2024-03-29T13:26:35Z"],"dc:date.available":["2024-03-29T13:26:35Z"],"dc:date.issued":["2024"],"dc:description":["University of Minnesota Ph.D. dissertation.--- 2024. Major: Biosystems and Agricultural Engineering. Advisor: Bruce Wilson. 1 computer file (PDF); vi, 102 pages."],"dc:description.abstract":["Pollution research and mitigation efforts rely on the accuracy of data collected by monitoring programs. I present work on improving monitoring protocols for two important pollutants. As a step towards improving the spatiotemporal resolution and lowering the cost of ground-level methane sensing, I design and thoroughly characterize an inexpensive sensor node for near-atmospheric methane monitoring. In an effort to improve stormwater monitoring methods, I develop a new model for runoff pollution and use it to simulate stormwater sampling, resulting in two suggested protocol modifications with the potential to substantially improve accuracy without increased cost. Throughout, I focus in particular on developing devices and methods that will improve monitoring accuracy or increase monitoring resolution at the same or lower cost as current approaches."],"dc:identifier.citation":["Furuta, Daniel. (2024). Low-Cost Improvements in Pollution Monitoring Methods. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/261980."],"dc:identifier.uri":["https://hdl.handle.net/11299/261980"],"dc:language.iso":["en"],"dc:title":["Low-Cost Improvements in Pollution Monitoring Methods"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:51:44Z"}