{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/269166"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/269166","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Ex-vivo capped end pulsation method as an alternative to measure pulse wave velocity","abstract":"Cardiovascular diseases (CVDs) continue to pose a significant global health challenge, underscoring the imperative need for the implementation of precise and non-invasive methodologies aimed at early detection and comprehensive assessment of vascular health. Identifying alterations in arterial stiffness has emerged as a crucial indicator of underlying pathological changes. Pulse wave velocity (PWV) a non-invasive measure of arterial stiffness, therefore, plays a pivotal role in the nuanced evaluation of cardiovascular health. This study introduces an ex-vivo innovative approach for measuring PWV, leveraging high-speed photography and image processing techniques to discern aortic tissue stiffness. A specially designed wave generator is fabricated to create a pressure wave within a fluid-filled test specimen, the terminus of which is capped to induce a standing wave. The ensuing dynamic wave propagation is recorded by a high-speed camera operating at a frequency of 1000 frames per second. The acquired images of the test specimen undergo a rigorous process of image processing and analysis to derive essential wave parameters. Subsequent calculations are then performed to ascertain the PWV, a critical metric in quantifying the stiffness of the test vessel through the application of the Moens-Korteweg equation. Beyond the development of this novel methodology, a validation study is undertaken, employing biomechanical uniaxial testing to provide a comprehensive evaluation of its reliability and accuracy. This multifaceted investigation underscores the potential of the proposed technique in advancing our understanding of cardiovascular health assessment methodologies. As CVDs persist as a leading cause of morbidity and mortality globally, the continued refinement of such methodologies holds promise for early detection and intervention strategies in the realm of cardiovascular health.","abstract_html":"Cardiovascular diseases (CVDs) continue to pose a significant global health challenge, underscoring the imperative need for the implementation of precise and non-invasive methodologies aimed at early detection and comprehensive assessment of vascular health. Identifying alterations in arterial stiffness has emerged as a crucial indicator of underlying pathological changes. Pulse wave velocity (PWV) a non-invasive measure of arterial stiffness, therefore, plays a pivotal role in the nuanced evaluation of cardiovascular health. This study introduces an ex-vivo innovative approach for measuring PWV, leveraging high-speed photography and image processing techniques to discern aortic tissue stiffness. A specially designed wave generator is fabricated to create a pressure wave within a fluid-filled test specimen, the terminus of which is capped to induce a standing wave. The ensuing dynamic wave propagation is recorded by a high-speed camera operating at a frequency of 1000 frames per second. The acquired images of the test specimen undergo a rigorous process of image processing and analysis to derive essential wave parameters. Subsequent calculations are then performed to ascertain the PWV, a critical metric in quantifying the stiffness of the test vessel through the application of the Moens-Korteweg equation. Beyond the development of this novel methodology, a validation study is undertaken, employing biomechanical uniaxial testing to provide a comprehensive evaluation of its reliability and accuracy. This multifaceted investigation underscores the potential of the proposed technique in advancing our understanding of cardiovascular health assessment methodologies. As CVDs persist as a leading cause of morbidity and mortality globally, the continued refinement of such methodologies holds promise for early detection and intervention strategies in the realm of cardiovascular health.","abstract_has_math":false,"creators":["Kulkarni, Manali Rajendra"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-07","date_published":"2024-07","updated_at":"2026-11-19T09:51:51Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Kulkarni, Manali Rajendra. (2024). Ex-vivo capped end pulsation method as an alternative to measure pulse wave velocity. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269166."],"render_values":[{"text":"Kulkarni, Manali Rajendra. (2024). Ex-vivo capped end pulsation method as an alternative to measure pulse wave velocity. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269166.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/269166","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/269166","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F269166","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kulkarni, Manali Rajendra"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-07T16:11:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-07T16:11:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-07"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Kulkarni, Manali Rajendra. (2024). Ex-vivo capped end pulsation method as an alternative to measure pulse wave velocity. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269166."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/269166"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. July 2024. Major: Mechanical Engineering. Advisor: Victor Barocas. 1 computer file (PDF); vi, 39 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Cardiovascular diseases (CVDs) continue to pose a significant global health challenge, underscoring the imperative need for the implementation of precise and non-invasive methodologies aimed at early detection and comprehensive assessment of vascular health. Identifying alterations in arterial stiffness has emerged as a crucial indicator of underlying pathological changes. Pulse wave velocity (PWV) a non-invasive measure of arterial stiffness, therefore, plays a pivotal role in the nuanced evaluation of cardiovascular health. This study introduces an ex-vivo innovative approach for measuring PWV, leveraging high-speed photography and image processing techniques to discern aortic tissue stiffness. A specially designed wave generator is fabricated to create a pressure wave within a fluid-filled test specimen, the terminus of which is capped to induce a standing wave. The ensuing dynamic wave propagation is recorded by a high-speed camera operating at a frequency of 1000 frames per second. The acquired images of the test specimen undergo a rigorous process of image processing and analysis to derive essential wave parameters. Subsequent calculations are then performed to ascertain the PWV, a critical metric in quantifying the stiffness of the test vessel through the application of the Moens-Korteweg equation. Beyond the development of this novel methodology, a validation study is undertaken, employing biomechanical uniaxial testing to provide a comprehensive evaluation of its reliability and accuracy. This multifaceted investigation underscores the potential of the proposed technique in advancing our understanding of cardiovascular health assessment methodologies. As CVDs persist as a leading cause of morbidity and mortality globally, the continued refinement of such methodologies holds promise for early detection and intervention strategies in the realm of cardiovascular health."]},{"key":"dc:title","label":"Title","values":["Ex-vivo capped end pulsation method as an alternative to measure pulse wave velocity"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Kulkarni, Manali Rajendra"],"dc:date.accessioned":["2025-01-07T16:11:02Z"],"dc:date.available":["2025-01-07T16:11:02Z"],"dc:date.issued":["2024-07"],"dc:description":["University of Minnesota M.S. thesis. July 2024. Major: Mechanical Engineering. Advisor: Victor Barocas. 1 computer file (PDF); vi, 39 pages."],"dc:description.abstract":["Cardiovascular diseases (CVDs) continue to pose a significant global health challenge, underscoring the imperative need for the implementation of precise and non-invasive methodologies aimed at early detection and comprehensive assessment of vascular health. Identifying alterations in arterial stiffness has emerged as a crucial indicator of underlying pathological changes. Pulse wave velocity (PWV) a non-invasive measure of arterial stiffness, therefore, plays a pivotal role in the nuanced evaluation of cardiovascular health. This study introduces an ex-vivo innovative approach for measuring PWV, leveraging high-speed photography and image processing techniques to discern aortic tissue stiffness. A specially designed wave generator is fabricated to create a pressure wave within a fluid-filled test specimen, the terminus of which is capped to induce a standing wave. The ensuing dynamic wave propagation is recorded by a high-speed camera operating at a frequency of 1000 frames per second. The acquired images of the test specimen undergo a rigorous process of image processing and analysis to derive essential wave parameters. Subsequent calculations are then performed to ascertain the PWV, a critical metric in quantifying the stiffness of the test vessel through the application of the Moens-Korteweg equation. Beyond the development of this novel methodology, a validation study is undertaken, employing biomechanical uniaxial testing to provide a comprehensive evaluation of its reliability and accuracy. This multifaceted investigation underscores the potential of the proposed technique in advancing our understanding of cardiovascular health assessment methodologies. As CVDs persist as a leading cause of morbidity and mortality globally, the continued refinement of such methodologies holds promise for early detection and intervention strategies in the realm of cardiovascular health."],"dc:identifier.citation":["Kulkarni, Manali Rajendra. (2024). Ex-vivo capped end pulsation method as an alternative to measure pulse wave velocity. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269166."],"dc:identifier.uri":["https://hdl.handle.net/11299/269166"],"dc:language.iso":["en"],"dc:title":["Ex-vivo capped end pulsation method as an alternative to measure pulse wave velocity"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:51:51Z"}