{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/269532"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/269532","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate","abstract":"Ground source heat pumps are a renewable energy option to reduce greenhouse gas emissions from building's space heating and cooling. Placing the heat exchanger within the structures of new homes creates a cost-effective “thermo-active foundation.” This research aims to explore the potential of “thermo-active foundations” with a double u-loop ground heat exchanger enhanced with a solar thermal collector and latent thermal energy storage. This study determines the appropriately sized solar collector needed at three locations to maintain the ground’s thermal balance, then the system was enhanced using phase change material as a thermal energy storage component. Results show the sized collectors without the thermal energy storage system, the overall coefficient of performance was 3.86, 3.79, and 3.98 for International Falls, Duluth, and Winona respectively. The enhanced results show that when incorporating phase change material, the coefficient of performance is 3.75, 3.82, and 3.86 for International Falls, Duluth, and Winona, respectively.","abstract_html":"Ground source heat pumps are a renewable energy option to reduce greenhouse gas emissions from building&#x27;s space heating and cooling. Placing the heat exchanger within the structures of new homes creates a cost-effective “thermo-active foundation.” This research aims to explore the potential of “thermo-active foundations” with a double u-loop ground heat exchanger enhanced with a solar thermal collector and latent thermal energy storage. This study determines the appropriately sized solar collector needed at three locations to maintain the ground’s thermal balance, then the system was enhanced using phase change material as a thermal energy storage component. Results show the sized collectors without the thermal energy storage system, the overall coefficient of performance was 3.86, 3.79, and 3.98 for International Falls, Duluth, and Winona respectively. The enhanced results show that when incorporating phase change material, the coefficient of performance is 3.75, 3.82, and 3.86 for International Falls, Duluth, and Winona, respectively.","abstract_has_math":false,"creators":["Gruenes, Jordan"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-08","date_published":"2024-08","updated_at":"2026-11-19T09:51:51Z","subjects":["cold climate","double u-loop","heat exhangers","solar-assisted","thermal energy storage","thermo-active foundation","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Mechanical Engineering","Department of Mechanical and Industrial Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Gruenes, Jordan. (2024). Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269532."],"render_values":[{"text":"Gruenes, Jordan. (2024). Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269532.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/269532","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/269532","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F269532","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F269532","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gruenes, Jordan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-28T20:30:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-28T20:30:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["cold climate","double u-loop","heat exhangers","solar-assisted","thermal energy storage","thermo-active foundation","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Mechanical Engineering","Department of Mechanical and Industrial Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Gruenes, Jordan. (2024). Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269532."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/269532"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S.M.E. thesis. August 2024. Major: Mechanical Engineering. Advisors: Alison Hoxie, Aggrey Mwesigye. 1 computer file (PDF); xi, 78 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Ground source heat pumps are a renewable energy option to reduce greenhouse gas emissions from building's space heating and cooling. Placing the heat exchanger within the structures of new homes creates a cost-effective “thermo-active foundation.” This research aims to explore the potential of “thermo-active foundations” with a double u-loop ground heat exchanger enhanced with a solar thermal collector and latent thermal energy storage. This study determines the appropriately sized solar collector needed at three locations to maintain the ground’s thermal balance, then the system was enhanced using phase change material as a thermal energy storage component. Results show the sized collectors without the thermal energy storage system, the overall coefficient of performance was 3.86, 3.79, and 3.98 for International Falls, Duluth, and Winona respectively. The enhanced results show that when incorporating phase change material, the coefficient of performance is 3.75, 3.82, and 3.86 for International Falls, Duluth, and Winona, respectively."]},{"key":"dc:title","label":"Title","values":["Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Gruenes, Jordan"],"dc:date.accessioned":["2025-01-28T20:30:29Z"],"dc:date.available":["2025-01-28T20:30:29Z"],"dc:date.issued":["2024-08"],"dc:description":["University of Minnesota M.S.M.E. thesis. August 2024. Major: Mechanical Engineering. Advisors: Alison Hoxie, Aggrey Mwesigye. 1 computer file (PDF); xi, 78 pages."],"dc:description.abstract":["Ground source heat pumps are a renewable energy option to reduce greenhouse gas emissions from building's space heating and cooling. Placing the heat exchanger within the structures of new homes creates a cost-effective “thermo-active foundation.” This research aims to explore the potential of “thermo-active foundations” with a double u-loop ground heat exchanger enhanced with a solar thermal collector and latent thermal energy storage. This study determines the appropriately sized solar collector needed at three locations to maintain the ground’s thermal balance, then the system was enhanced using phase change material as a thermal energy storage component. Results show the sized collectors without the thermal energy storage system, the overall coefficient of performance was 3.86, 3.79, and 3.98 for International Falls, Duluth, and Winona respectively. The enhanced results show that when incorporating phase change material, the coefficient of performance is 3.75, 3.82, and 3.86 for International Falls, Duluth, and Winona, respectively."],"dc:identifier.citation":["Gruenes, Jordan. (2024). Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269532."],"dc:identifier.uri":["https://hdl.handle.net/11299/269532"],"dc:language.iso":["en"],"dc:subject":["cold climate","double u-loop","heat exhangers","solar-assisted","thermal energy storage","thermo-active foundation","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Mechanical Engineering","Department of Mechanical and Industrial Engineering","Swenson College of Science and Engineering","University of Minnesota Duluth"],"dc:title":["Thermal performance of solar-assisted thermo-active foundation with a double u-loop heat exchanger in a cold climate"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:51:51Z"}