{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/269547"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/269547","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Conformational Analysis of Hetero-FRET Environmental Biosensors Using Time-Resolved Two-Photon Fluorescence Depolarization","abstract":"Living cells are complex and encompass heterogeneous and dynamic environments. Here, we investigated a family of protein-based donor-linker-acceptor constructs in controlled environments of varying macromolecular crowding and ionic strength. Once the donor undergoes two-photon (2P) excitation with 850-nm laser pulses, Förster resonance energy transfer (FRET) can occur from the donor to the acceptor. The sensitivity of these sensors was examined using newly developed time-resolved 2P fluorescence depolarization spectroscopy, where the parallel and perpendicular fluorescence polarizations of mostly the acceptor were simultaneously detected. Our results reveal that the sensitivity of the crowding sensors is dependent upon the donor’s mutations. For ionic strength sensing, the sensitivity of a sensor with two oppositely charged α-helices in the linker region was more sensitive in comparison to a single charged α-helix. Taken together, these optimized methodologies represent a step towards our goal of noninvasive, site-specific, quantitative, and sensitive in vivo mapping of environmental conditions.","abstract_html":"Living cells are complex and encompass heterogeneous and dynamic environments. Here, we investigated a family of protein-based donor-linker-acceptor constructs in controlled environments of varying macromolecular crowding and ionic strength. Once the donor undergoes two-photon (2P) excitation with 850-nm laser pulses, Förster resonance energy transfer (FRET) can occur from the donor to the acceptor. The sensitivity of these sensors was examined using newly developed time-resolved 2P fluorescence depolarization spectroscopy, where the parallel and perpendicular fluorescence polarizations of mostly the acceptor were simultaneously detected. Our results reveal that the sensitivity of the crowding sensors is dependent upon the donor’s mutations. For ionic strength sensing, the sensitivity of a sensor with two oppositely charged α-helices in the linker region was more sensitive in comparison to a single charged α-helix. Taken together, these optimized methodologies represent a step towards our goal of noninvasive, site-specific, quantitative, and sensitive in vivo mapping of environmental conditions.","abstract_has_math":false,"creators":["Simonet, Rowan"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-08","date_published":"2022-08","updated_at":"2026-11-19T09:52:01Z","subjects":["Anisotropy","Biophysics","Depolarization","Fluorescence","FRET","Time-resolved","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Chemistry","Department of Chemistry and Biochemistry","Swenson College of Science and Engineering","University of Minnesota Duluth"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Simonet, Rowan. (2022). Conformational Analysis of Hetero-FRET Environmental Biosensors Using Time-Resolved Two-Photon Fluorescence Depolarization. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269547."],"render_values":[{"text":"Simonet, Rowan. (2022). Conformational Analysis of Hetero-FRET Environmental Biosensors Using Time-Resolved Two-Photon Fluorescence Depolarization. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269547.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/269547","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/269547","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F269547","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F269547","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Simonet, Rowan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-28T20:30:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-28T20:30:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Anisotropy","Biophysics","Depolarization","Fluorescence","FRET","Time-resolved","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Chemistry","Department of Chemistry and Biochemistry","Swenson College of Science and Engineering","University of Minnesota Duluth"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Simonet, Rowan. (2022). Conformational Analysis of Hetero-FRET Environmental Biosensors Using Time-Resolved Two-Photon Fluorescence Depolarization. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269547."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/269547"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. August 2022. Major: Chemistry. Advisors: Ahmed Heikal, Erin Sheets. 1 computer file (PDF); xii, 132 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Living cells are complex and encompass heterogeneous and dynamic environments. Here, we investigated a family of protein-based donor-linker-acceptor constructs in controlled environments of varying macromolecular crowding and ionic strength. Once the donor undergoes two-photon (2P) excitation with 850-nm laser pulses, Förster resonance energy transfer (FRET) can occur from the donor to the acceptor. The sensitivity of these sensors was examined using newly developed time-resolved 2P fluorescence depolarization spectroscopy, where the parallel and perpendicular fluorescence polarizations of mostly the acceptor were simultaneously detected. Our results reveal that the sensitivity of the crowding sensors is dependent upon the donor’s mutations. For ionic strength sensing, the sensitivity of a sensor with two oppositely charged α-helices in the linker region was more sensitive in comparison to a single charged α-helix. Taken together, these optimized methodologies represent a step towards our goal of noninvasive, site-specific, quantitative, and sensitive in vivo mapping of environmental conditions."]},{"key":"dc:title","label":"Title","values":["Conformational Analysis of Hetero-FRET Environmental Biosensors Using Time-Resolved Two-Photon Fluorescence Depolarization"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Simonet, Rowan"],"dc:date.accessioned":["2025-01-28T20:30:34Z"],"dc:date.available":["2025-01-28T20:30:34Z"],"dc:date.issued":["2022-08"],"dc:description":["University of Minnesota M.S. thesis. August 2022. Major: Chemistry. Advisors: Ahmed Heikal, Erin Sheets. 1 computer file (PDF); xii, 132 pages."],"dc:description.abstract":["Living cells are complex and encompass heterogeneous and dynamic environments. Here, we investigated a family of protein-based donor-linker-acceptor constructs in controlled environments of varying macromolecular crowding and ionic strength. Once the donor undergoes two-photon (2P) excitation with 850-nm laser pulses, Förster resonance energy transfer (FRET) can occur from the donor to the acceptor. The sensitivity of these sensors was examined using newly developed time-resolved 2P fluorescence depolarization spectroscopy, where the parallel and perpendicular fluorescence polarizations of mostly the acceptor were simultaneously detected. Our results reveal that the sensitivity of the crowding sensors is dependent upon the donor’s mutations. For ionic strength sensing, the sensitivity of a sensor with two oppositely charged α-helices in the linker region was more sensitive in comparison to a single charged α-helix. Taken together, these optimized methodologies represent a step towards our goal of noninvasive, site-specific, quantitative, and sensitive in vivo mapping of environmental conditions."],"dc:identifier.citation":["Simonet, Rowan. (2022). Conformational Analysis of Hetero-FRET Environmental Biosensors Using Time-Resolved Two-Photon Fluorescence Depolarization. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/269547."],"dc:identifier.uri":["https://hdl.handle.net/11299/269547"],"dc:language.iso":["en"],"dc:subject":["Anisotropy","Biophysics","Depolarization","Fluorescence","FRET","Time-resolved","Plan As (thesis-based master's degrees)","Master of Science","Master of Science in Chemistry","Department of Chemistry and Biochemistry","Swenson College of Science and Engineering","University of Minnesota Duluth"],"dc:title":["Conformational Analysis of Hetero-FRET Environmental Biosensors Using Time-Resolved Two-Photon Fluorescence Depolarization"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:52:01Z"}