{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/278135"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/278135","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Developing RF safety strategies at high field and ultra-high field MRI","abstract":"Radiofrequency (RF) safety remains a critical concern in high field and ultra-high field magnetic resonance imaging (MRI), especially for patients with implanted medical devices such as deep brain stimulation (DBS) systems. This thesis addresses two central aims which are improving RF safety for patients with DBS implants and demonstrating the feasibility of conducting RF safety assessment beyond traditional scanner-based methods. Chapter 2 validates a patient-specific heating prediction workflow in a bilateral DBS configuration using an anthropomorphic phantom to accurately estimate heating near the electrical contacts for varying bilateral trajectories. Chapter 3 extends this validation to in vivo and postmortem swine models, accounting for tissue heterogeneity and perfusion effects, and further explores the use of a toroidal transceiver for artifact-reduced imaging near the DBS electrode in intraoperative MRI. Chapter 4 presented an implant-friendly (IF) RF excitation optimization workflow as a technique to reduce RF artifacts and heating risk in both phantom and patient imaging studies. Chapter 5 focused on presenting different RF safety validations that were conducted in a controlled B0-free RF safety lab across multiple frequencies, including SAR distribution mapping, DBS transfer function measurement, and hardware failure analysis. The validation results across all chapters highlight practical solutions to current RF safety limitations.","abstract_html":"Radiofrequency (RF) safety remains a critical concern in high field and ultra-high field magnetic resonance imaging (MRI), especially for patients with implanted medical devices such as deep brain stimulation (DBS) systems. This thesis addresses two central aims which are improving RF safety for patients with DBS implants and demonstrating the feasibility of conducting RF safety assessment beyond traditional scanner-based methods. Chapter 2 validates a patient-specific heating prediction workflow in a bilateral DBS configuration using an anthropomorphic phantom to accurately estimate heating near the electrical contacts for varying bilateral trajectories. Chapter 3 extends this validation to in vivo and postmortem swine models, accounting for tissue heterogeneity and perfusion effects, and further explores the use of a toroidal transceiver for artifact-reduced imaging near the DBS electrode in intraoperative MRI. Chapter 4 presented an implant-friendly (IF) RF excitation optimization workflow as a technique to reduce RF artifacts and heating risk in both phantom and patient imaging studies. Chapter 5 focused on presenting different RF safety validations that were conducted in a controlled B0-free RF safety lab across multiple frequencies, including SAR distribution mapping, DBS transfer function measurement, and hardware failure analysis. The validation results across all chapters highlight practical solutions to current RF safety limitations.","abstract_has_math":false,"creators":["Zulkarnain-Lemke, Nur Izzati Huda"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-07","date_published":"2025-07","updated_at":"2026-11-19T09:52:11Z","subjects":["Deep brain stimulation","Medical physics","MRI","RF safety"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zulkarnain-Lemke, Nur Izzati Huda. (2025). Developing RF safety strategies at high field and ultra-high field MRI. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/278135."],"render_values":[{"text":"Zulkarnain-Lemke, Nur Izzati Huda. (2025). Developing RF safety strategies at high field and ultra-high field MRI. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/278135.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/278135","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/278135","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aumn%3Aoai%3Aconservancy.umn.edu%3A11299%2F278135","prefix":"oai_dc"},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F278135","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Zulkarnain-Lemke, Nur Izzati Huda"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-02-03T19:57:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-07"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Deep brain stimulation","Medical physics","MRI","RF safety"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zulkarnain-Lemke, Nur Izzati Huda. (2025). Developing RF safety strategies at high field and ultra-high field MRI. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/278135."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/278135"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota Ph.D. dissertation. July 2025. Major: Physics. Advisor: Yigitcan Eryaman. 1 computer file (PDF); vii, 91 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Radiofrequency (RF) safety remains a critical concern in high field and ultra-high field magnetic resonance imaging (MRI), especially for patients with implanted medical devices such as deep brain stimulation (DBS) systems. This thesis addresses two central aims which are improving RF safety for patients with DBS implants and demonstrating the feasibility of conducting RF safety assessment beyond traditional scanner-based methods. Chapter 2 validates a patient-specific heating prediction workflow in a bilateral DBS configuration using an anthropomorphic phantom to accurately estimate heating near the electrical contacts for varying bilateral trajectories. Chapter 3 extends this validation to in vivo and postmortem swine models, accounting for tissue heterogeneity and perfusion effects, and further explores the use of a toroidal transceiver for artifact-reduced imaging near the DBS electrode in intraoperative MRI. Chapter 4 presented an implant-friendly (IF) RF excitation optimization workflow as a technique to reduce RF artifacts and heating risk in both phantom and patient imaging studies. Chapter 5 focused on presenting different RF safety validations that were conducted in a controlled B0-free RF safety lab across multiple frequencies, including SAR distribution mapping, DBS transfer function measurement, and hardware failure analysis. The validation results across all chapters highlight practical solutions to current RF safety limitations."]},{"key":"dc:title","label":"Title","values":["Developing RF safety strategies at high field and ultra-high field MRI"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Zulkarnain-Lemke, Nur Izzati Huda"],"dc:date.accessioned":["2026-02-03T19:57:55Z"],"dc:date.issued":["2025-07"],"dc:description":["University of Minnesota Ph.D. dissertation. July 2025. Major: Physics. Advisor: Yigitcan Eryaman. 1 computer file (PDF); vii, 91 pages."],"dc:description.abstract":["Radiofrequency (RF) safety remains a critical concern in high field and ultra-high field magnetic resonance imaging (MRI), especially for patients with implanted medical devices such as deep brain stimulation (DBS) systems. This thesis addresses two central aims which are improving RF safety for patients with DBS implants and demonstrating the feasibility of conducting RF safety assessment beyond traditional scanner-based methods. Chapter 2 validates a patient-specific heating prediction workflow in a bilateral DBS configuration using an anthropomorphic phantom to accurately estimate heating near the electrical contacts for varying bilateral trajectories. Chapter 3 extends this validation to in vivo and postmortem swine models, accounting for tissue heterogeneity and perfusion effects, and further explores the use of a toroidal transceiver for artifact-reduced imaging near the DBS electrode in intraoperative MRI. Chapter 4 presented an implant-friendly (IF) RF excitation optimization workflow as a technique to reduce RF artifacts and heating risk in both phantom and patient imaging studies. Chapter 5 focused on presenting different RF safety validations that were conducted in a controlled B0-free RF safety lab across multiple frequencies, including SAR distribution mapping, DBS transfer function measurement, and hardware failure analysis. The validation results across all chapters highlight practical solutions to current RF safety limitations."],"dc:identifier.citation":["Zulkarnain-Lemke, Nur Izzati Huda. (2025). Developing RF safety strategies at high field and ultra-high field MRI. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/278135."],"dc:identifier.uri":["https://hdl.handle.net/11299/278135"],"dc:language.iso":["en"],"dc:subject":["Deep brain stimulation","Medical physics","MRI","RF safety"],"dc:title":["Developing RF safety strategies at high field and ultra-high field MRI"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:52:11Z"}