{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/281040"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/281040","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Design and Optical Validation of a Spinal Window for In Vivo Imaging in Rats","abstract":"Longitudinal in vivo imaging of the spinal cord remains technically challenging in rat models; advancements in this technology would be highly beneficial for studying spinal cord injury. This study evaluated the feasibility of developing a dorsal spinal window platform to support short-term survival and fluorescence-based imaging in Long-Evans rats. Through iterative prototyping, terminal compatibility testing, and short-term survival implantation surgeries, the mechanical stability and geometric constraints of the implant were characterized. These procedures assessed implant fit, fixation strategy, muscle management, and early post-operative outcomes, including wound integrity and absence of infection. A polyethylene terephthalate (PET) film interface was integrated into the design and evaluated overall using imaging techniques. In vivo imaging identified critical mechanical and optical limitations related to objective working distance constraints, tissue-to-window separation, and physiologic motion. Together, these findings define the mechanical and optical parameters necessary to refine rat spinal window platforms, paving the way for more effective longitudinal imaging approaches in preclinical spinal cord injury research.","abstract_html":"Longitudinal in vivo imaging of the spinal cord remains technically challenging in rat models; advancements in this technology would be highly beneficial for studying spinal cord injury. This study evaluated the feasibility of developing a dorsal spinal window platform to support short-term survival and fluorescence-based imaging in Long-Evans rats. Through iterative prototyping, terminal compatibility testing, and short-term survival implantation surgeries, the mechanical stability and geometric constraints of the implant were characterized. These procedures assessed implant fit, fixation strategy, muscle management, and early post-operative outcomes, including wound integrity and absence of infection. A polyethylene terephthalate (PET) film interface was integrated into the design and evaluated overall using imaging techniques. In vivo imaging identified critical mechanical and optical limitations related to objective working distance constraints, tissue-to-window separation, and physiologic motion. Together, these findings define the mechanical and optical parameters necessary to refine rat spinal window platforms, paving the way for more effective longitudinal imaging approaches in preclinical spinal cord injury research.","abstract_has_math":false,"creators":["Pandey, Shivangi"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T09:52:16Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Pandey, Shivangi. (2026). Design and Optical Validation of a Spinal Window for In Vivo Imaging in Rats. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/281040."],"render_values":[{"text":"Pandey, Shivangi. (2026). Design and Optical Validation of a Spinal Window for In Vivo Imaging in Rats. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/281040.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/281040","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/281040","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F281040","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pandey, Shivangi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-06-17T18:38:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Pandey, Shivangi. (2026). Design and Optical Validation of a Spinal Window for In Vivo Imaging in Rats. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/281040."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/281040"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S.M.E. thesis. 2026. Major: Mechanical Engineering. Advisors: Michael McAlpine, Ann Parr. 1 computer file (PDF); viii, 77 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Longitudinal in vivo imaging of the spinal cord remains technically challenging in rat models; advancements in this technology would be highly beneficial for studying spinal cord injury. This study evaluated the feasibility of developing a dorsal spinal window platform to support short-term survival and fluorescence-based imaging in Long-Evans rats. Through iterative prototyping, terminal compatibility testing, and short-term survival implantation surgeries, the mechanical stability and geometric constraints of the implant were characterized. These procedures assessed implant fit, fixation strategy, muscle management, and early post-operative outcomes, including wound integrity and absence of infection. A polyethylene terephthalate (PET) film interface was integrated into the design and evaluated overall using imaging techniques. In vivo imaging identified critical mechanical and optical limitations related to objective working distance constraints, tissue-to-window separation, and physiologic motion. Together, these findings define the mechanical and optical parameters necessary to refine rat spinal window platforms, paving the way for more effective longitudinal imaging approaches in preclinical spinal cord injury research."]},{"key":"dc:title","label":"Title","values":["Design and Optical Validation of a Spinal Window for In Vivo Imaging in Rats"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Pandey, Shivangi"],"dc:date.accessioned":["2026-06-17T18:38:36Z"],"dc:date.issued":["2026"],"dc:description":["University of Minnesota M.S.M.E. thesis. 2026. Major: Mechanical Engineering. Advisors: Michael McAlpine, Ann Parr. 1 computer file (PDF); viii, 77 pages."],"dc:description.abstract":["Longitudinal in vivo imaging of the spinal cord remains technically challenging in rat models; advancements in this technology would be highly beneficial for studying spinal cord injury. This study evaluated the feasibility of developing a dorsal spinal window platform to support short-term survival and fluorescence-based imaging in Long-Evans rats. Through iterative prototyping, terminal compatibility testing, and short-term survival implantation surgeries, the mechanical stability and geometric constraints of the implant were characterized. These procedures assessed implant fit, fixation strategy, muscle management, and early post-operative outcomes, including wound integrity and absence of infection. A polyethylene terephthalate (PET) film interface was integrated into the design and evaluated overall using imaging techniques. In vivo imaging identified critical mechanical and optical limitations related to objective working distance constraints, tissue-to-window separation, and physiologic motion. Together, these findings define the mechanical and optical parameters necessary to refine rat spinal window platforms, paving the way for more effective longitudinal imaging approaches in preclinical spinal cord injury research."],"dc:identifier.citation":["Pandey, Shivangi. (2026). Design and Optical Validation of a Spinal Window for In Vivo Imaging in Rats. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/281040."],"dc:identifier.uri":["https://hdl.handle.net/11299/281040"],"dc:language.iso":["en"],"dc:title":["Design and Optical Validation of a Spinal Window for In Vivo Imaging in Rats"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:52:16Z"}