{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/282277"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/282277","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results","abstract":"This prospective, multi-center clinical study was completed to evaluate the initial clinical performance of the T3 Pro dental implant system from ZimVie. The T3 Pro implant incorporates a multi-level surface, with acid-etched, fine-micron features and coarse-micron features along the entire surface of the implant as well as sharp cutting flutes and self-tapping thread design with increasing thread depth toward the apex. A total of 32 implants were placed in 31 patients. Exclusion criteria included uncontrolled metabolic diseases, uncontrolled periodontal disease, history of head & neck radiation, and current use of bisphosphonates. Initial implant parameters reported include insertion torque value (Ncm) and resonance frequency measure (ISQ) at implant placement. Initial mean torque value for all implants was 36.5 Ncm, and initial mean ISQ value was 79. Immediate implants demonstrated a mean torque value of 37.9 Ncm and mean ISQ value of 68.6 compared to delayed implant mean torque value of 39.4 Ncm and a mean ISQ value of 68.6. Neither of these differences in measures were statistically significant. Overall, one implant failed during the early healing phase resulting in an early implant survival rate of 96.9% (31/32 implants). Within the limitations of the study, including a relatively small sample size, only reporting early surgical and healing phases, and lack of control, the T3 Pro implant system by ZimVie demonstrated favorable early clinical results and promising surgical performance.","abstract_html":"This prospective, multi-center clinical study was completed to evaluate the initial clinical performance of the T3 Pro dental implant system from ZimVie. The T3 Pro implant incorporates a multi-level surface, with acid-etched, fine-micron features and coarse-micron features along the entire surface of the implant as well as sharp cutting flutes and self-tapping thread design with increasing thread depth toward the apex. A total of 32 implants were placed in 31 patients. Exclusion criteria included uncontrolled metabolic diseases, uncontrolled periodontal disease, history of head &amp; neck radiation, and current use of bisphosphonates. Initial implant parameters reported include insertion torque value (Ncm) and resonance frequency measure (ISQ) at implant placement. Initial mean torque value for all implants was 36.5 Ncm, and initial mean ISQ value was 79. Immediate implants demonstrated a mean torque value of 37.9 Ncm and mean ISQ value of 68.6 compared to delayed implant mean torque value of 39.4 Ncm and a mean ISQ value of 68.6. Neither of these differences in measures were statistically significant. Overall, one implant failed during the early healing phase resulting in an early implant survival rate of 96.9% (31/32 implants). Within the limitations of the study, including a relatively small sample size, only reporting early surgical and healing phases, and lack of control, the T3 Pro implant system by ZimVie demonstrated favorable early clinical results and promising surgical performance.","abstract_has_math":false,"creators":["Cory, Maxwell"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-06","date_published":"2026-06","updated_at":"2026-11-19T09:52:16Z","subjects":["Dental","Implant","Osseoitite","T3 Pro","ZimVie"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Cory, Maxwell. (2026). Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/282277."],"render_values":[{"text":"Cory, Maxwell. (2026). Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/282277.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/282277","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/282277","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F282277","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Cory, Maxwell"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-24T13:20:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dental","Implant","Osseoitite","T3 Pro","ZimVie"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Cory, Maxwell. (2026). Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/282277."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/282277"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. June 2026. Major: Dentistry. Advisor: Ioannis Kormas. 1 computer file (PDF); viii, 49 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["This prospective, multi-center clinical study was completed to evaluate the initial clinical performance of the T3 Pro dental implant system from ZimVie. The T3 Pro implant incorporates a multi-level surface, with acid-etched, fine-micron features and coarse-micron features along the entire surface of the implant as well as sharp cutting flutes and self-tapping thread design with increasing thread depth toward the apex. A total of 32 implants were placed in 31 patients. Exclusion criteria included uncontrolled metabolic diseases, uncontrolled periodontal disease, history of head & neck radiation, and current use of bisphosphonates. Initial implant parameters reported include insertion torque value (Ncm) and resonance frequency measure (ISQ) at implant placement. Initial mean torque value for all implants was 36.5 Ncm, and initial mean ISQ value was 79. Immediate implants demonstrated a mean torque value of 37.9 Ncm and mean ISQ value of 68.6 compared to delayed implant mean torque value of 39.4 Ncm and a mean ISQ value of 68.6. Neither of these differences in measures were statistically significant. Overall, one implant failed during the early healing phase resulting in an early implant survival rate of 96.9% (31/32 implants). Within the limitations of the study, including a relatively small sample size, only reporting early surgical and healing phases, and lack of control, the T3 Pro implant system by ZimVie demonstrated favorable early clinical results and promising surgical performance."]},{"key":"dc:title","label":"Title","values":["Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Cory, Maxwell"],"dc:date.accessioned":["2026-09-24T13:20:04Z"],"dc:date.issued":["2026-06"],"dc:description":["University of Minnesota M.S. thesis. June 2026. Major: Dentistry. Advisor: Ioannis Kormas. 1 computer file (PDF); viii, 49 pages."],"dc:description.abstract":["This prospective, multi-center clinical study was completed to evaluate the initial clinical performance of the T3 Pro dental implant system from ZimVie. The T3 Pro implant incorporates a multi-level surface, with acid-etched, fine-micron features and coarse-micron features along the entire surface of the implant as well as sharp cutting flutes and self-tapping thread design with increasing thread depth toward the apex. A total of 32 implants were placed in 31 patients. Exclusion criteria included uncontrolled metabolic diseases, uncontrolled periodontal disease, history of head & neck radiation, and current use of bisphosphonates. Initial implant parameters reported include insertion torque value (Ncm) and resonance frequency measure (ISQ) at implant placement. Initial mean torque value for all implants was 36.5 Ncm, and initial mean ISQ value was 79. Immediate implants demonstrated a mean torque value of 37.9 Ncm and mean ISQ value of 68.6 compared to delayed implant mean torque value of 39.4 Ncm and a mean ISQ value of 68.6. Neither of these differences in measures were statistically significant. Overall, one implant failed during the early healing phase resulting in an early implant survival rate of 96.9% (31/32 implants). Within the limitations of the study, including a relatively small sample size, only reporting early surgical and healing phases, and lack of control, the T3 Pro implant system by ZimVie demonstrated favorable early clinical results and promising surgical performance."],"dc:identifier.citation":["Cory, Maxwell. (2026). Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/282277."],"dc:identifier.uri":["https://hdl.handle.net/11299/282277"],"dc:language.iso":["en"],"dc:subject":["Dental","Implant","Osseoitite","T3 Pro","ZimVie"],"dc:title":["Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:52:16Z"}