{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/283032"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/283032","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Analysis of Propylene Glycol in Human Saliva Samples Using Gas Chromatography-Mass Spectrometry","abstract":"This thesis aimed to develop a specific biomarker to distinguish e-cigarette users from users of other nicotine-containing products such as nicotine replacement therapy (NRT), cigarettes and smokeless tobacco, and non-users. Hence, we proposed, developed and validated an analytical method to quantify propylene glycol (PG) in human saliva. The sample will be combined with the internal standard (PG-d8) and undergo heptafluorobutyric anhydride derivatization of the internal standard spiked sample to produce di-heptafluorobutyrate esters of PG and PG-d6. This is followed by a liquid-liquid extraction step to eliminate the sample matrix, food particles, and enzymes. Finally, we used gas chromatography coupled with single quadrupole mass spectrometry (GC-MS), and PG and PG-d8 will be monitored using m/z 241 and m/z 245. Then, we analyzed samples collected from a collaborative study with University of Minnesota’s Tobacco Research Programs comparing salivary PG levels in non-users, cigarette smokers, and e-cigarette users. Our data indicate that there are ~550-fold higher levels of salivary PG among e-cigarette users than non-users. Finally, we have developed an accurate and precise GC-MS method for quantifying PG in saliva samples. This analytical method could be added to the arsenal of biomarkers in clinical settings, such as a compliance checker for cessation programs to ensure study participants do not vape.","abstract_html":"This thesis aimed to develop a specific biomarker to distinguish e-cigarette users from users of other nicotine-containing products such as nicotine replacement therapy (NRT), cigarettes and smokeless tobacco, and non-users. Hence, we proposed, developed and validated an analytical method to quantify propylene glycol (PG) in human saliva. The sample will be combined with the internal standard (PG-d8) and undergo heptafluorobutyric anhydride derivatization of the internal standard spiked sample to produce di-heptafluorobutyrate esters of PG and PG-d6. This is followed by a liquid-liquid extraction step to eliminate the sample matrix, food particles, and enzymes. Finally, we used gas chromatography coupled with single quadrupole mass spectrometry (GC-MS), and PG and PG-d8 will be monitored using m/z 241 and m/z 245. Then, we analyzed samples collected from a collaborative study with University of Minnesota’s Tobacco Research Programs comparing salivary PG levels in non-users, cigarette smokers, and e-cigarette users. Our data indicate that there are ~550-fold higher levels of salivary PG among e-cigarette users than non-users. Finally, we have developed an accurate and precise GC-MS method for quantifying PG in saliva samples. This analytical method could be added to the arsenal of biomarkers in clinical settings, such as a compliance checker for cessation programs to ensure study participants do not vape.","abstract_has_math":false,"creators":["Tang, Mei-Kuen"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-08","date_published":"2022-08","updated_at":"2026-11-19T09:52:16Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Tang, Mei-Kuen. (2022). Analysis of Propylene Glycol in Human Saliva Samples Using Gas Chromatography-Mass Spectrometry. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/283032."],"render_values":[{"text":"Tang, Mei-Kuen. (2022). Analysis of Propylene Glycol in Human Saliva Samples Using Gas Chromatography-Mass Spectrometry. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/283032.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11299/283032","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11299/283032","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F283032","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Tang, Mei-Kuen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-28T15:09:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Tang, Mei-Kuen. (2022). Analysis of Propylene Glycol in Human Saliva Samples Using Gas Chromatography-Mass Spectrometry. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/283032."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11299/283032"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. August 2022. Major: Pharmacology. Advisor: Stephen Hecht. 1 computer file (PDF); ix, 54 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis aimed to develop a specific biomarker to distinguish e-cigarette users from users of other nicotine-containing products such as nicotine replacement therapy (NRT), cigarettes and smokeless tobacco, and non-users. Hence, we proposed, developed and validated an analytical method to quantify propylene glycol (PG) in human saliva. The sample will be combined with the internal standard (PG-d8) and undergo heptafluorobutyric anhydride derivatization of the internal standard spiked sample to produce di-heptafluorobutyrate esters of PG and PG-d6. This is followed by a liquid-liquid extraction step to eliminate the sample matrix, food particles, and enzymes. Finally, we used gas chromatography coupled with single quadrupole mass spectrometry (GC-MS), and PG and PG-d8 will be monitored using m/z 241 and m/z 245. Then, we analyzed samples collected from a collaborative study with University of Minnesota’s Tobacco Research Programs comparing salivary PG levels in non-users, cigarette smokers, and e-cigarette users. Our data indicate that there are ~550-fold higher levels of salivary PG among e-cigarette users than non-users. Finally, we have developed an accurate and precise GC-MS method for quantifying PG in saliva samples. This analytical method could be added to the arsenal of biomarkers in clinical settings, such as a compliance checker for cessation programs to ensure study participants do not vape."]},{"key":"dc:title","label":"Title","values":["Analysis of Propylene Glycol in Human Saliva Samples Using Gas Chromatography-Mass Spectrometry"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Tang, Mei-Kuen"],"dc:date.accessioned":["2026-10-28T15:09:44Z"],"dc:date.issued":["2022-08"],"dc:description":["University of Minnesota M.S. thesis. August 2022. Major: Pharmacology. Advisor: Stephen Hecht. 1 computer file (PDF); ix, 54 pages."],"dc:description.abstract":["This thesis aimed to develop a specific biomarker to distinguish e-cigarette users from users of other nicotine-containing products such as nicotine replacement therapy (NRT), cigarettes and smokeless tobacco, and non-users. Hence, we proposed, developed and validated an analytical method to quantify propylene glycol (PG) in human saliva. The sample will be combined with the internal standard (PG-d8) and undergo heptafluorobutyric anhydride derivatization of the internal standard spiked sample to produce di-heptafluorobutyrate esters of PG and PG-d6. This is followed by a liquid-liquid extraction step to eliminate the sample matrix, food particles, and enzymes. Finally, we used gas chromatography coupled with single quadrupole mass spectrometry (GC-MS), and PG and PG-d8 will be monitored using m/z 241 and m/z 245. Then, we analyzed samples collected from a collaborative study with University of Minnesota’s Tobacco Research Programs comparing salivary PG levels in non-users, cigarette smokers, and e-cigarette users. Our data indicate that there are ~550-fold higher levels of salivary PG among e-cigarette users than non-users. Finally, we have developed an accurate and precise GC-MS method for quantifying PG in saliva samples. This analytical method could be added to the arsenal of biomarkers in clinical settings, such as a compliance checker for cessation programs to ensure study participants do not vape."],"dc:identifier.citation":["Tang, Mei-Kuen. (2022). Analysis of Propylene Glycol in Human Saliva Samples Using Gas Chromatography-Mass Spectrometry. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/283032."],"dc:identifier.uri":["https://hdl.handle.net/11299/283032"],"dc:language.iso":["en"],"dc:title":["Analysis of Propylene Glycol in Human Saliva Samples Using Gas Chromatography-Mass Spectrometry"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:52:16Z"}