{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/59834"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/59834","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Novel microfluidic technologies: toward a low-cost system for protein crystallization.","abstract":"The three-dimensional structure of folded proteins is of enormous interest to the scientific community. The structure is best determined with x-ray diffraction through a protein crystal, but it has proven extremely difficult to grow crystals large enough for this process [1, 2]. Significant challenges faced by protein crystallographers include the inability to sufficiently control the crystallization environment and the scarcity of protein available [3]. Microfluidic devices, which allow ultra-precise fluid management and require significantly less reagent than traditional methods, constitute an ideal technology with which to overcome these crystallization challenges [4-7]. A microfluidic system has been designed to give a crystallographer precise management of the concentrations of several reagents (such as protein and a suitable precipitant salt) over time. To create components of the microfluidic system, two novel fabrication methods were developed: photopolymer mold making and three-dimensional plate tectonics. These methods are rapid, inexpensive, and do not require any special equipment. A novel micropump and channel network suitable for the crystallization system were successfully created using these techniques.","abstract_html":"The three-dimensional structure of folded proteins is of enormous interest to the scientific community. The structure is best determined with x-ray diffraction through a protein crystal, but it has proven extremely difficult to grow crystals large enough for this process [1, 2]. Significant challenges faced by protein crystallographers include the inability to sufficiently control the crystallization environment and the scarcity of protein available [3]. Microfluidic devices, which allow ultra-precise fluid management and require significantly less reagent than traditional methods, constitute an ideal technology with which to overcome these crystallization challenges [4-7]. A microfluidic system has been designed to give a crystallographer precise management of the concentrations of several reagents (such as protein and a suitable precipitant salt) over time. To create components of the microfluidic system, two novel fabrication methods were developed: photopolymer mold making and three-dimensional plate tectonics. These methods are rapid, inexpensive, and do not require any special equipment. A novel micropump and channel network suitable for the crystallization system were successfully created using these techniques.","abstract_has_math":false,"creators":["Hattan, Paul J"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-12","date_published":"2009-12","updated_at":"2026-11-19T09:52:31Z","subjects":["Crystallization","Three-dimensional plate tectonics","Microfluidic system","Protein","Biomedical Engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Hattan, Paul J. (2009). Novel microfluidic technologies: toward a low-cost system for protein crystallization.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/59834."],"render_values":[{"text":"Hattan, Paul J. (2009). Novel microfluidic technologies: toward a low-cost system for protein crystallization.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/59834.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/59834","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/59834","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F59834","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hattan, Paul J"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-03-26T20:22:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-03-26T20:22:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-12"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Crystallization","Three-dimensional plate tectonics","Microfluidic system","Protein","Biomedical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Hattan, Paul J. (2009). Novel microfluidic technologies: toward a low-cost system for protein crystallization.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/59834."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/59834"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. December 2009. Major: Biomedical Engineering. Advisor: Victor Barocas. 1 computer file (PDF); ii, 47 pages. Ill., (some col.)"]},{"key":"dc:description.abstract","label":"Abstract","values":["The three-dimensional structure of folded proteins is of enormous interest to the scientific community. The structure is best determined with x-ray diffraction through a protein crystal, but it has proven extremely difficult to grow crystals large enough for this process [1, 2]. Significant challenges faced by protein crystallographers include the inability to sufficiently control the crystallization environment and the scarcity of protein available [3]. Microfluidic devices, which allow ultra-precise fluid management and require significantly less reagent than traditional methods, constitute an ideal technology with which to overcome these crystallization challenges [4-7]. A microfluidic system has been designed to give a crystallographer precise management of the concentrations of several reagents (such as protein and a suitable precipitant salt) over time. To create components of the microfluidic system, two novel fabrication methods were developed: photopolymer mold making and three-dimensional plate tectonics. These methods are rapid, inexpensive, and do not require any special equipment. A novel micropump and channel network suitable for the crystallization system were successfully created using these techniques."]},{"key":"dc:title","label":"Title","values":["Novel microfluidic technologies: toward a low-cost system for protein crystallization."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Hattan, Paul J"],"dc:date.accessioned":["2010-03-26T20:22:52Z"],"dc:date.available":["2010-03-26T20:22:52Z"],"dc:date.issued":["2009-12"],"dc:description":["University of Minnesota M.S. thesis. December 2009. Major: Biomedical Engineering. Advisor: Victor Barocas. 1 computer file (PDF); ii, 47 pages. Ill., (some col.)"],"dc:description.abstract":["The three-dimensional structure of folded proteins is of enormous interest to the scientific community. The structure is best determined with x-ray diffraction through a protein crystal, but it has proven extremely difficult to grow crystals large enough for this process [1, 2]. Significant challenges faced by protein crystallographers include the inability to sufficiently control the crystallization environment and the scarcity of protein available [3]. Microfluidic devices, which allow ultra-precise fluid management and require significantly less reagent than traditional methods, constitute an ideal technology with which to overcome these crystallization challenges [4-7]. A microfluidic system has been designed to give a crystallographer precise management of the concentrations of several reagents (such as protein and a suitable precipitant salt) over time. To create components of the microfluidic system, two novel fabrication methods were developed: photopolymer mold making and three-dimensional plate tectonics. These methods are rapid, inexpensive, and do not require any special equipment. A novel micropump and channel network suitable for the crystallization system were successfully created using these techniques."],"dc:identifier.citation":["Hattan, Paul J. (2009). Novel microfluidic technologies: toward a low-cost system for protein crystallization.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/59834."],"dc:identifier.uri":["http://purl.umn.edu/59834"],"dc:language.iso":["en_US"],"dc:subject":["Crystallization","Three-dimensional plate tectonics","Microfluidic system","Protein","Biomedical Engineering"],"dc:title":["Novel microfluidic technologies: toward a low-cost system for protein crystallization."],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:52:31Z"}