{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/96879"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/96879","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Heat testing methodology comparison.","abstract":"Pre-operative pulpal and periapical diagnosis is critical for effective and appropriate endodontic treatment. Occasionally patients present with a chief complaint involving hypersensitivity to heat – a hallmark sign of irreversible pulpitis. In an attempt to replicate this chief complaint, a variety of clinical methods have been developed to deliver a heat stimulus to a tooth. Friction from a burlew wheel, heated gutta-percha, a heated instrument, and hot water have all been used to warm teeth. Recently, an instrument has been developed which is heated electronically and placed directly against a tooth. The aim of this study was to determine which of these methods produces the most consistent temperature rise within the pulp of a tooth. The value of this consistency is that it allows clinical differentiation between a normal pulp and a pulp demonstrating irreversible pulpitis. The present study used extracted maxillary teeth with thermocouples mounted within the pulp chamber. Four operators applied the following methods to the teeth: heated gutta-percha, heated ball burnisher, hot water, and an electronic probe attached first to a System B™ and then to an Elements™ unit. Each test was performed for 60 seconds, and the temperature recorded every half-second. Analysis of the data revealed the most consistent warming of the pulp was accomplished with the electronic probe attached to the Elements™ unit. The lowest level of consistency was found with hot water. The electronic probe also yielded temperature changes which were more consistent between operators compared to the other three methods.","abstract_html":"Pre-operative pulpal and periapical diagnosis is critical for effective and appropriate endodontic treatment. Occasionally patients present with a chief complaint involving hypersensitivity to heat – a hallmark sign of irreversible pulpitis. In an attempt to replicate this chief complaint, a variety of clinical methods have been developed to deliver a heat stimulus to a tooth. Friction from a burlew wheel, heated gutta-percha, a heated instrument, and hot water have all been used to warm teeth. Recently, an instrument has been developed which is heated electronically and placed directly against a tooth. The aim of this study was to determine which of these methods produces the most consistent temperature rise within the pulp of a tooth. The value of this consistency is that it allows clinical differentiation between a normal pulp and a pulp demonstrating irreversible pulpitis. The present study used extracted maxillary teeth with thermocouples mounted within the pulp chamber. Four operators applied the following methods to the teeth: heated gutta-percha, heated ball burnisher, hot water, and an electronic probe attached first to a System B™ and then to an Elements™ unit. Each test was performed for 60 seconds, and the temperature recorded every half-second. Analysis of the data revealed the most consistent warming of the pulp was accomplished with the electronic probe attached to the Elements™ unit. The lowest level of consistency was found with hot water. The electronic probe also yielded temperature changes which were more consistent between operators compared to the other three methods.","abstract_has_math":false,"creators":["Bierma, Mark M."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-08","date_published":"2010-08","updated_at":"2026-11-19T09:52:40Z","subjects":["Temperature","Pulpitis","Tooth","Dentistry"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Bierma, Mark M.. (2010). Heat testing methodology comparison.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/96879."],"render_values":[{"text":"Bierma, Mark M.. (2010). Heat testing methodology comparison.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/96879.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/96879","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/96879","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F96879","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bierma, Mark M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-11-19T16:54:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-11-19T16:54:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Temperature","Pulpitis","Tooth","Dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Bierma, Mark M.. (2010). Heat testing methodology comparison.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/96879."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/96879"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota M.S. thesis. August 2010. Major: Dentistry. Advisor: Dr. Baisden. 1 computer file (PDF); vi, 35 pages."]},{"key":"dc:description.abstract","label":"Abstract","values":["Pre-operative pulpal and periapical diagnosis is critical for effective and appropriate endodontic treatment. Occasionally patients present with a chief complaint involving hypersensitivity to heat – a hallmark sign of irreversible pulpitis. In an attempt to replicate this chief complaint, a variety of clinical methods have been developed to deliver a heat stimulus to a tooth. Friction from a burlew wheel, heated gutta-percha, a heated instrument, and hot water have all been used to warm teeth. Recently, an instrument has been developed which is heated electronically and placed directly against a tooth. The aim of this study was to determine which of these methods produces the most consistent temperature rise within the pulp of a tooth. The value of this consistency is that it allows clinical differentiation between a normal pulp and a pulp demonstrating irreversible pulpitis. The present study used extracted maxillary teeth with thermocouples mounted within the pulp chamber. Four operators applied the following methods to the teeth: heated gutta-percha, heated ball burnisher, hot water, and an electronic probe attached first to a System B™ and then to an Elements™ unit. Each test was performed for 60 seconds, and the temperature recorded every half-second. Analysis of the data revealed the most consistent warming of the pulp was accomplished with the electronic probe attached to the Elements™ unit. The lowest level of consistency was found with hot water. The electronic probe also yielded temperature changes which were more consistent between operators compared to the other three methods."]},{"key":"dc:title","label":"Title","values":["Heat testing methodology comparison."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Bierma, Mark M."],"dc:date.accessioned":["2010-11-19T16:54:45Z"],"dc:date.available":["2010-11-19T16:54:45Z"],"dc:date.issued":["2010-08"],"dc:description":["University of Minnesota M.S. thesis. August 2010. Major: Dentistry. Advisor: Dr. Baisden. 1 computer file (PDF); vi, 35 pages."],"dc:description.abstract":["Pre-operative pulpal and periapical diagnosis is critical for effective and appropriate endodontic treatment. Occasionally patients present with a chief complaint involving hypersensitivity to heat – a hallmark sign of irreversible pulpitis. In an attempt to replicate this chief complaint, a variety of clinical methods have been developed to deliver a heat stimulus to a tooth. Friction from a burlew wheel, heated gutta-percha, a heated instrument, and hot water have all been used to warm teeth. Recently, an instrument has been developed which is heated electronically and placed directly against a tooth. The aim of this study was to determine which of these methods produces the most consistent temperature rise within the pulp of a tooth. The value of this consistency is that it allows clinical differentiation between a normal pulp and a pulp demonstrating irreversible pulpitis. The present study used extracted maxillary teeth with thermocouples mounted within the pulp chamber. Four operators applied the following methods to the teeth: heated gutta-percha, heated ball burnisher, hot water, and an electronic probe attached first to a System B™ and then to an Elements™ unit. Each test was performed for 60 seconds, and the temperature recorded every half-second. Analysis of the data revealed the most consistent warming of the pulp was accomplished with the electronic probe attached to the Elements™ unit. The lowest level of consistency was found with hot water. The electronic probe also yielded temperature changes which were more consistent between operators compared to the other three methods."],"dc:identifier.citation":["Bierma, Mark M.. (2010). Heat testing methodology comparison.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/96879."],"dc:identifier.uri":["http://purl.umn.edu/96879"],"dc:language.iso":["en_US"],"dc:subject":["Temperature","Pulpitis","Tooth","Dentistry"],"dc:title":["Heat testing methodology comparison."],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:52:40Z"}