{"id":{"repo_id":"umn","oai_identifier":"oai:conservancy.umn.edu:11299/99238"},"canonical_url":"https://search.ndltd.org/etd/umn/oai:conservancy.umn.edu:11299/99238","repository":{"repo_id":"umn","name":"University of Minnesota","base_url":"https://conservancy.umn.edu/server/oai/request"},"display":{"title":"Polarization-sensitive optical coherence tomography using polarization-maintaining fibers","abstract":"Optical Coherence Tomography (OCT) is a sensitive imaging technique that generates cross-sectional images of turbid tissues with a micrometer-scale resolution. Polarization-Sensitive (PS) OCT adds additional contrast to OCT by detecting polarization alterations within tissues, and provides accurate OCT images in polarization-altering tissues. Common approaches to build PSOCT are either: simple but difficult to incorporate in clinics and laboratories, or fiber-based and flexible but expensive, sophisticated, and computationally demanding. We have developed a new approach to build PSOCT using Polarization-Maintaining Fibers (PMF). A single depth scan is sufficient to calculate reflectivity, retardance, and axis orientation information using computationally-inexpensive algorithms. We present novel PMF-based PSOCT systems and demonstrate sensitivity figures larger than 100 dB, equivalent to common approaches. The developed PMF-based interferometers are used to measure minute Faraday rotations in tissue-mimicking phantoms, and the polarization properties of unmyelinated nerves. A novel algorithm is also developed to correct for errors calculating the birefringence of samples, and generate interpretable PSOCT images.","abstract_html":"Optical Coherence Tomography (OCT) is a sensitive imaging technique that generates cross-sectional images of turbid tissues with a micrometer-scale resolution. Polarization-Sensitive (PS) OCT adds additional contrast to OCT by detecting polarization alterations within tissues, and provides accurate OCT images in polarization-altering tissues. Common approaches to build PSOCT are either: simple but difficult to incorporate in clinics and laboratories, or fiber-based and flexible but expensive, sophisticated, and computationally demanding. We have developed a new approach to build PSOCT using Polarization-Maintaining Fibers (PMF). A single depth scan is sufficient to calculate reflectivity, retardance, and axis orientation information using computationally-inexpensive algorithms. We present novel PMF-based PSOCT systems and demonstrate sensitivity figures larger than 100 dB, equivalent to common approaches. The developed PMF-based interferometers are used to measure minute Faraday rotations in tissue-mimicking phantoms, and the polarization properties of unmyelinated nerves. A novel algorithm is also developed to correct for errors calculating the birefringence of samples, and generate interpretable PSOCT images.","abstract_has_math":false,"creators":["Al-Qaisi, Muhammad K."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-12","date_published":"2010-12","updated_at":"2026-11-19T09:52:40Z","subjects":["Birefringence","Faraday effect","Imaging","Phase measurement","Polarization","Polarization-sensetive optical coherence tomography","Biomedical Engineering"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Al-Qaisi, Muhammad K.. (2010). Polarization-sensitive optical coherence tomography using polarization-maintaining fibers. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/99238."],"render_values":[{"text":"Al-Qaisi, Muhammad K.. (2010). Polarization-sensitive optical coherence tomography using polarization-maintaining fibers. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/99238.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://purl.umn.edu/99238","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"http://purl.umn.edu/99238","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://conservancy.umn.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aconservancy.umn.edu%3A11299%2F99238","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Al-Qaisi, Muhammad K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-01-24T20:10:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-01-24T20:10:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-12"]},{"key":"dc:type","label":"Dc Type","values":["Thesis or Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Birefringence","Faraday effect","Imaging","Phase measurement","Polarization","Polarization-sensetive optical coherence tomography","Biomedical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Al-Qaisi, Muhammad K.. (2010). Polarization-sensitive optical coherence tomography using polarization-maintaining fibers. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/99238."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://purl.umn.edu/99238"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["University of Minnesota Ph.D. dissertation. December 2010. Major: Biomedical Engineering. Advisor: Taner Akkin. 1 computer file (PDF); xxii, 171 pages, appendices A-D. Ill. (some col.)"]},{"key":"dc:description.abstract","label":"Abstract","values":["Optical Coherence Tomography (OCT) is a sensitive imaging technique that generates cross-sectional images of turbid tissues with a micrometer-scale resolution. Polarization-Sensitive (PS) OCT adds additional contrast to OCT by detecting polarization alterations within tissues, and provides accurate OCT images in polarization-altering tissues. Common approaches to build PSOCT are either: simple but difficult to incorporate in clinics and laboratories, or fiber-based and flexible but expensive, sophisticated, and computationally demanding. We have developed a new approach to build PSOCT using Polarization-Maintaining Fibers (PMF). A single depth scan is sufficient to calculate reflectivity, retardance, and axis orientation information using computationally-inexpensive algorithms. We present novel PMF-based PSOCT systems and demonstrate sensitivity figures larger than 100 dB, equivalent to common approaches. The developed PMF-based interferometers are used to measure minute Faraday rotations in tissue-mimicking phantoms, and the polarization properties of unmyelinated nerves. A novel algorithm is also developed to correct for errors calculating the birefringence of samples, and generate interpretable PSOCT images."]},{"key":"dc:title","label":"Title","values":["Polarization-sensitive optical coherence tomography using polarization-maintaining fibers"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Al-Qaisi, Muhammad K."],"dc:date.accessioned":["2011-01-24T20:10:15Z"],"dc:date.available":["2011-01-24T20:10:15Z"],"dc:date.issued":["2010-12"],"dc:description":["University of Minnesota Ph.D. dissertation. December 2010. Major: Biomedical Engineering. Advisor: Taner Akkin. 1 computer file (PDF); xxii, 171 pages, appendices A-D. Ill. (some col.)"],"dc:description.abstract":["Optical Coherence Tomography (OCT) is a sensitive imaging technique that generates cross-sectional images of turbid tissues with a micrometer-scale resolution. Polarization-Sensitive (PS) OCT adds additional contrast to OCT by detecting polarization alterations within tissues, and provides accurate OCT images in polarization-altering tissues. Common approaches to build PSOCT are either: simple but difficult to incorporate in clinics and laboratories, or fiber-based and flexible but expensive, sophisticated, and computationally demanding. We have developed a new approach to build PSOCT using Polarization-Maintaining Fibers (PMF). A single depth scan is sufficient to calculate reflectivity, retardance, and axis orientation information using computationally-inexpensive algorithms. We present novel PMF-based PSOCT systems and demonstrate sensitivity figures larger than 100 dB, equivalent to common approaches. The developed PMF-based interferometers are used to measure minute Faraday rotations in tissue-mimicking phantoms, and the polarization properties of unmyelinated nerves. A novel algorithm is also developed to correct for errors calculating the birefringence of samples, and generate interpretable PSOCT images."],"dc:identifier.citation":["Al-Qaisi, Muhammad K.. (2010). Polarization-sensitive optical coherence tomography using polarization-maintaining fibers. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/99238."],"dc:identifier.uri":["http://purl.umn.edu/99238"],"dc:language.iso":["en_US"],"dc:subject":["Birefringence","Faraday effect","Imaging","Phase measurement","Polarization","Polarization-sensetive optical coherence tomography","Biomedical Engineering"],"dc:title":["Polarization-sensitive optical coherence tomography using polarization-maintaining fibers"],"dc:type":["Thesis or Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T09:52:40Z"}