{"id":{"repo_id":"unf","oai_identifier":"oai:digitalcommons.unf.edu:etd-1475"},"canonical_url":"https://search.ndltd.org/etd/unf/oai:digitalcommons.unf.edu:etd-1475","repository":{"repo_id":"unf","name":"University of North Florida","base_url":"https://digitalcommons.unf.edu/do/oai/"},"display":{"title":"Development of a Predictive Model for Bulk-Flow Through A Porous Polymer Membrane Tube","abstract":"While extensive mathematical and numerical work has been done in terms of modeling the mainstream flow in a tube with porous walls, very little has been done experimentally to confirm these various solutions, and what has been done has focused on large sintered metal tubes used in nuclear power applications. Furthermore, these solutions are quite mathematically complex and arduous to implement. In this work, the mainstream flow through a porous polymer membrane tube is examined and a method for calculating the through-membrane flow rate and axial pressure drop is presented. Two membrane tubes are tested experimentally, and a simple set of modeling equations that are physically intuitive are presented which fit the data. A characterization test is described which can be used to determine the permeability coefficient, kD, for a membrane sample, which can in turn be used to calculate the through-membrane flow rate and axial pressure drop. The models are then evaluated by performing flow-through experiments and measuring the pressures and flows within the membrane. For both membranes tested, the permeability coefficient is determined to be kD = 5.9394 × 10−14 m2 . For the tube diameters (2 mm and 8 mm) and flow rates (100-500 sccm) tested, it is shown that for dimensionless tube lengths bL = L/(dReD) ≥ 0.3, a model that assumes fully developed flow through the entire tube accurately describes the through-membrane flow rate data. The fully-developed model consistently under-predicts the experimental data for axial pressure drop, therefore it is assumed that the discrepancy is due to an additional pressure loss from the developing region. This loss is determined empirically using the data. The model’s validity is examined and compared to that of other authors for the range of flow rates tested.","abstract_html":"While extensive mathematical and numerical work has been done in terms of modeling the mainstream flow in a tube with porous walls, very little has been done experimentally to confirm these various solutions, and what has been done has focused on large sintered metal tubes used in nuclear power applications. Furthermore, these solutions are quite mathematically complex and arduous to implement. In this work, the mainstream flow through a porous polymer membrane tube is examined and a method for calculating the through-membrane flow rate and axial pressure drop is presented. Two membrane tubes are tested experimentally, and a simple set of modeling equations that are physically intuitive are presented which fit the data. A characterization test is described which can be used to determine the permeability coefficient, kD, for a membrane sample, which can in turn be used to calculate the through-membrane flow rate and axial pressure drop. The models are then evaluated by performing flow-through experiments and measuring the pressures and flows within the membrane. For both membranes tested, the permeability coefficient is determined to be kD = 5.9394 × 10−14 m2 . For the tube diameters (2 mm and 8 mm) and flow rates (100-500 sccm) tested, it is shown that for dimensionless tube lengths bL = L/(dReD) ≥ 0.3, a model that assumes fully developed flow through the entire tube accurately describes the through-membrane flow rate data. The fully-developed model consistently under-predicts the experimental data for axial pressure drop, therefore it is assumed that the discrepancy is due to an additional pressure loss from the developing region. This loss is determined empirically using the data. The model’s validity is examined and compared to that of other authors for the range of flow rates tested.","abstract_has_math":false,"creators":["Meles, Aaron Robert"],"institution":"UNF Digital Commons","degree_name":"Master of Science in Mechanical Engineering (MSME)","degree_level":null,"degree_discipline":"Engineering","degree_department":null,"school":null,"contributors":["Dr. James Fletcher","Dr. Richard V. Conte","Dr. Adel El-Safty"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"Spring","date_published":"Spring","updated_at":"2026-11-18T20:03:36Z","subjects":["Thesis; University of North Florida; UNF; Dissertations","Academic – UNF – Master of Science in Mechanical Engineering; Dissertations","Academic – UNF – Engineering","Applied Mechanics","Mechanical Engineering","Dissertations","Academic -- UNF -- Mechanical Engineering; Fluid mechanics -- Mathematical models; Membranes (Technology);"],"languages":[],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.unf.edu/etd/406","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.unf.edu/etd/406","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://digitalcommons.unf.edu/context/etd/article/1475/viewcontent/ETD1108PAC.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.unf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.unf.edu%3Aetd-1475","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. James Fletcher","Dr. Richard V. Conte","Dr. Adel El-Safty"]},{"key":"dc:creator","label":"Author","values":["Meles, Aaron Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2013-09-24T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-01-01T08:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["Spring"]},{"key":"dc:publisher","label":"Institution","values":["UNF Digital Commons"]},{"key":"dc:type","label":"Dc Type","values":["Master's Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MSME)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Thesis; University of North Florida; UNF; Dissertations","Academic – UNF – Master of Science in Mechanical Engineering; Dissertations","Academic – UNF – Engineering","Applied Mechanics","Mechanical Engineering"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Dissertations","Academic -- UNF -- Mechanical Engineering; Fluid mechanics -- Mathematical models; Membranes (Technology);"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.unf.edu/etd/406","https://digitalcommons.unf.edu/context/etd/article/1475/viewcontent/ETD1108PAC.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["While extensive mathematical and numerical work has been done in terms of modeling the mainstream flow in a tube with porous walls, very little has been done experimentally to confirm these various solutions, and what has been done has focused on large sintered metal tubes used in nuclear power applications. Furthermore, these solutions are quite mathematically complex and arduous to implement. In this work, the mainstream flow through a porous polymer membrane tube is examined and a method for calculating the through-membrane flow rate and axial pressure drop is presented. Two membrane tubes are tested experimentally, and a simple set of modeling equations that are physically intuitive are presented which fit the data. A characterization test is described which can be used to determine the permeability coefficient, kD, for a membrane sample, which can in turn be used to calculate the through-membrane flow rate and axial pressure drop. The models are then evaluated by performing flow-through experiments and measuring the pressures and flows within the membrane. For both membranes tested, the permeability coefficient is determined to be kD = 5.9394 × 10−14 m2 . For the tube diameters (2 mm and 8 mm) and flow rates (100-500 sccm) tested, it is shown that for dimensionless tube lengths bL = L/(dReD) ≥ 0.3, a model that assumes fully developed flow through the entire tube accurately describes the through-membrane flow rate data. The fully-developed model consistently under-predicts the experimental data for axial pressure drop, therefore it is assumed that the discrepancy is due to an additional pressure loss from the developing region. This loss is determined empirically using the data. The model’s validity is examined and compared to that of other authors for the range of flow rates tested."]},{"key":"dc:title","label":"Title","values":["Development of a Predictive Model for Bulk-Flow Through A Porous Polymer Membrane Tube"]}]}],"canonical_facts":{"dc:contributor":["Dr. James Fletcher","Dr. Richard V. Conte","Dr. Adel El-Safty"],"dc:creator":["Meles, Aaron Robert"],"dc:date.available":["2013-09-24T07:00:00Z"],"dc:date.created":["2012-01-01T08:00:00Z"],"dc:date.issued":["Spring"],"dc:description.abstract":["While extensive mathematical and numerical work has been done in terms of modeling the mainstream flow in a tube with porous walls, very little has been done experimentally to confirm these various solutions, and what has been done has focused on large sintered metal tubes used in nuclear power applications. Furthermore, these solutions are quite mathematically complex and arduous to implement. In this work, the mainstream flow through a porous polymer membrane tube is examined and a method for calculating the through-membrane flow rate and axial pressure drop is presented. Two membrane tubes are tested experimentally, and a simple set of modeling equations that are physically intuitive are presented which fit the data. A characterization test is described which can be used to determine the permeability coefficient, kD, for a membrane sample, which can in turn be used to calculate the through-membrane flow rate and axial pressure drop. The models are then evaluated by performing flow-through experiments and measuring the pressures and flows within the membrane. For both membranes tested, the permeability coefficient is determined to be kD = 5.9394 × 10−14 m2 . For the tube diameters (2 mm and 8 mm) and flow rates (100-500 sccm) tested, it is shown that for dimensionless tube lengths bL = L/(dReD) ≥ 0.3, a model that assumes fully developed flow through the entire tube accurately describes the through-membrane flow rate data. The fully-developed model consistently under-predicts the experimental data for axial pressure drop, therefore it is assumed that the discrepancy is due to an additional pressure loss from the developing region. This loss is determined empirically using the data. The model’s validity is examined and compared to that of other authors for the range of flow rates tested."],"dc:identifier":["https://digitalcommons.unf.edu/etd/406","https://digitalcommons.unf.edu/context/etd/article/1475/viewcontent/ETD1108PAC.pdf"],"dc:publisher":["UNF Digital Commons"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Thesis; University of North Florida; UNF; Dissertations","Academic – UNF – Master of Science in Mechanical Engineering; Dissertations","Academic – UNF – Engineering","Applied Mechanics","Mechanical Engineering"],"dc:subject.lcsh":["Dissertations","Academic -- UNF -- Mechanical Engineering; Fluid mechanics -- Mathematical models; Membranes (Technology);"],"dc:title":["Development of a Predictive Model for Bulk-Flow Through A Porous Polymer Membrane Tube"],"dc:type":["Master's Thesis"],"thesis:degree_discipline":["Engineering"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MSME)"]},"updated_at":"2026-11-18T20:03:36Z"}