{"id":{"repo_id":"unf","oai_identifier":"oai:digitalcommons.unf.edu:etd-2503"},"canonical_url":"https://search.ndltd.org/etd/unf/oai:digitalcommons.unf.edu:etd-2503","repository":{"repo_id":"unf","name":"University of North Florida","base_url":"https://digitalcommons.unf.edu/do/oai/"},"display":{"title":"Mechanical behavior of additively manufactured TI-6AL-4V ELI parts: Effects of laser parameter selection","abstract":"Additive manufacturing (AM) of TI-6AL‑4V Extra‑Low Interstitial (ELI) enables complex geometries for fatigue‑critical medical device applications, yet fatigue performance remains sensitive to process‑induced defects. This work investigates the effect of laser process parameter selection on the microstructure, mechanical properties, and fatigue behavior of TI- 6AL‑4V ELI fabricated via laser powder bed fusion (L‑PBF) using a Renishaw RenAM system. The influence of laser parameters was isolated by holding powder chemistry, build orientation, scan strategy, sub‑transus annealing, and post‑processing constant between a non‑optimized baseline and an optimized parameter set selected based on tensile performance. Optical microscopy showed the optimized condition exhibited improved microstructural quality, reflected by reduced porosity and less pronounced raster track features, consistent with improved melt pool stability. Tensile testing demonstrated increased ultimate tensile strength and elongation to failure for the optimized condition. Four‑point bending fatigue tests conducted in accordance with ASTM F382 revealed higher mean fatigue life and the occurrence of runout specimens at lower applied stress levels relative to the baseline condition, while higher stress levels produced increased scatter. Fractographic analysis confirmed surface‑initiated fatigue cracking associated with surface‑connected lack‑of‑fusion defects in both conditions, with reduced defect severity observed for optimized specimens. The experimentally observed crack initiation locations were consistent with stress concentration regions identified using finite element analysis of the ASTM F382 test configuration. These results suggest that tensile‑based laser parameter selection may be an effective approach for improving fatigue performance in AM TI-6AL‑4V ELI, while highlighting the importance of surface defect mitigation for fatigue‑critical medical device applications.","abstract_html":"Additive manufacturing (AM) of TI-6AL‑4V Extra‑Low Interstitial (ELI) enables complex geometries for fatigue‑critical medical device applications, yet fatigue performance remains sensitive to process‑induced defects. This work investigates the effect of laser process parameter selection on the microstructure, mechanical properties, and fatigue behavior of TI- 6AL‑4V ELI fabricated via laser powder bed fusion (L‑PBF) using a Renishaw RenAM system. The influence of laser parameters was isolated by holding powder chemistry, build orientation, scan strategy, sub‑transus annealing, and post‑processing constant between a non‑optimized baseline and an optimized parameter set selected based on tensile performance. Optical microscopy showed the optimized condition exhibited improved microstructural quality, reflected by reduced porosity and less pronounced raster track features, consistent with improved melt pool stability. Tensile testing demonstrated increased ultimate tensile strength and elongation to failure for the optimized condition. Four‑point bending fatigue tests conducted in accordance with ASTM F382 revealed higher mean fatigue life and the occurrence of runout specimens at lower applied stress levels relative to the baseline condition, while higher stress levels produced increased scatter. Fractographic analysis confirmed surface‑initiated fatigue cracking associated with surface‑connected lack‑of‑fusion defects in both conditions, with reduced defect severity observed for optimized specimens. The experimentally observed crack initiation locations were consistent with stress concentration regions identified using finite element analysis of the ASTM F382 test configuration. These results suggest that tensile‑based laser parameter selection may be an effective approach for improving fatigue performance in AM TI-6AL‑4V ELI, while highlighting the importance of surface defect mitigation for fatigue‑critical medical device applications.","abstract_has_math":false,"creators":["Lopez, Samuel","Lopez, Samuel, Jr., 1977-"],"institution":"University of North Florida. School of Engineering","degree_name":"Master of Science in Material Science & Engineering (MS)","degree_level":null,"degree_discipline":"Engineering","degree_department":null,"school":null,"contributors":["Dr. Jutima Simsiriwong","Dr. Nelson Delfino de Campos Neto","Dr. Alexandra Schonning","Dr. Albina Mikhaylova"],"advisors":["Simsiriwong, Jutima","de Campos Neto, Nelson Delfino","Schonning, Alexandra","Mikhaylova, Albina"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"Spring","date_published":"Spring","updated_at":"2026-11-18T20:04:27Z","subjects":["Thesis","University of North Florida","UNF","Dissertations, Academic -- UNF -- Master of Science in Material Science & Engineering","Dissertations, Academic -- UNF -- Engineering","Additive Manufacturing","Laser powder bed fusion (L-PBF)","Ti-6AL-4V ELI","Titanium Alloys","Fatigue Behavior","Mechanical Properties","Manufacturing","Other Materials Science and Engineering","Titanium alloys -- Mechanical properties -- Testing; Additive manufacturing -- Testing; Titanium alloys -- Fatigue -- Testing; Biomedical materials -- Technological innovations; Titanium alloys -- Industrial applications"],"languages":[],"rights":[],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.unf.edu/etd/1406","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.unf.edu/etd/1406","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://digitalcommons.unf.edu/context/etd/article/2503/viewcontent/ETD1973PA.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.unf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.unf.edu%3Aetd-2503","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Jutima Simsiriwong","Dr. Nelson Delfino de Campos Neto","Dr. Alexandra Schonning","Dr. Albina Mikhaylova"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Simsiriwong, Jutima","de Campos Neto, Nelson Delfino","Schonning, Alexandra","Mikhaylova, Albina"]},{"key":"dc:creator","label":"Author","values":["Lopez, Samuel","Lopez, Samuel, Jr., 1977-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-05-08T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-01-01T08:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["Spring"]},{"key":"dc:type","label":"Dc Type","values":["Master's Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Material Science & Engineering (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of North Florida. School of Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Thesis","University of North Florida","UNF","Dissertations, Academic -- UNF -- Master of Science in Material Science & Engineering","Dissertations, Academic -- UNF -- Engineering","Additive Manufacturing","Laser powder bed fusion (L-PBF)","Ti-6AL-4V ELI","Titanium Alloys","Fatigue Behavior","Mechanical Properties","Manufacturing","Other Materials Science and Engineering"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Titanium alloys -- Mechanical properties -- Testing; Additive manufacturing -- Testing; Titanium alloys -- Fatigue -- Testing; Biomedical materials -- Technological innovations; Titanium alloys -- Industrial applications"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.unf.edu/etd/1406","https://digitalcommons.unf.edu/context/etd/article/2503/viewcontent/ETD1973PA.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Additive manufacturing (AM) of TI-6AL‑4V Extra‑Low Interstitial (ELI) enables complex geometries for fatigue‑critical medical device applications, yet fatigue performance remains sensitive to process‑induced defects. This work investigates the effect of laser process parameter selection on the microstructure, mechanical properties, and fatigue behavior of TI- 6AL‑4V ELI fabricated via laser powder bed fusion (L‑PBF) using a Renishaw RenAM system. The influence of laser parameters was isolated by holding powder chemistry, build orientation, scan strategy, sub‑transus annealing, and post‑processing constant between a non‑optimized baseline and an optimized parameter set selected based on tensile performance. Optical microscopy showed the optimized condition exhibited improved microstructural quality, reflected by reduced porosity and less pronounced raster track features, consistent with improved melt pool stability. Tensile testing demonstrated increased ultimate tensile strength and elongation to failure for the optimized condition. Four‑point bending fatigue tests conducted in accordance with ASTM F382 revealed higher mean fatigue life and the occurrence of runout specimens at lower applied stress levels relative to the baseline condition, while higher stress levels produced increased scatter. Fractographic analysis confirmed surface‑initiated fatigue cracking associated with surface‑connected lack‑of‑fusion defects in both conditions, with reduced defect severity observed for optimized specimens. The experimentally observed crack initiation locations were consistent with stress concentration regions identified using finite element analysis of the ASTM F382 test configuration. These results suggest that tensile‑based laser parameter selection may be an effective approach for improving fatigue performance in AM TI-6AL‑4V ELI, while highlighting the importance of surface defect mitigation for fatigue‑critical medical device applications."]},{"key":"dc:description.note","label":"Dc Description Note","values":["ProQuest: No"]},{"key":"dc:title","label":"Title","values":["Mechanical behavior of additively manufactured TI-6AL-4V ELI parts: Effects of laser parameter selection"]}]}],"canonical_facts":{"dc:contributor":["Dr. Jutima Simsiriwong","Dr. Nelson Delfino de Campos Neto","Dr. Alexandra Schonning","Dr. Albina Mikhaylova"],"dc:contributor.advisor":["Simsiriwong, Jutima","de Campos Neto, Nelson Delfino","Schonning, Alexandra","Mikhaylova, Albina"],"dc:creator":["Lopez, Samuel","Lopez, Samuel, Jr., 1977-"],"dc:date.available":["2026-05-08T07:00:00Z"],"dc:date.created":["2026-01-01T08:00:00Z"],"dc:date.issued":["Spring"],"dc:description.abstract":["Additive manufacturing (AM) of TI-6AL‑4V Extra‑Low Interstitial (ELI) enables complex geometries for fatigue‑critical medical device applications, yet fatigue performance remains sensitive to process‑induced defects. This work investigates the effect of laser process parameter selection on the microstructure, mechanical properties, and fatigue behavior of TI- 6AL‑4V ELI fabricated via laser powder bed fusion (L‑PBF) using a Renishaw RenAM system. The influence of laser parameters was isolated by holding powder chemistry, build orientation, scan strategy, sub‑transus annealing, and post‑processing constant between a non‑optimized baseline and an optimized parameter set selected based on tensile performance. Optical microscopy showed the optimized condition exhibited improved microstructural quality, reflected by reduced porosity and less pronounced raster track features, consistent with improved melt pool stability. Tensile testing demonstrated increased ultimate tensile strength and elongation to failure for the optimized condition. Four‑point bending fatigue tests conducted in accordance with ASTM F382 revealed higher mean fatigue life and the occurrence of runout specimens at lower applied stress levels relative to the baseline condition, while higher stress levels produced increased scatter. Fractographic analysis confirmed surface‑initiated fatigue cracking associated with surface‑connected lack‑of‑fusion defects in both conditions, with reduced defect severity observed for optimized specimens. The experimentally observed crack initiation locations were consistent with stress concentration regions identified using finite element analysis of the ASTM F382 test configuration. These results suggest that tensile‑based laser parameter selection may be an effective approach for improving fatigue performance in AM TI-6AL‑4V ELI, while highlighting the importance of surface defect mitigation for fatigue‑critical medical device applications."],"dc:description.note":["ProQuest: No"],"dc:identifier":["https://digitalcommons.unf.edu/etd/1406","https://digitalcommons.unf.edu/context/etd/article/2503/viewcontent/ETD1973PA.pdf"],"dc:rights":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Thesis","University of North Florida","UNF","Dissertations, Academic -- UNF -- Master of Science in Material Science & Engineering","Dissertations, Academic -- UNF -- Engineering","Additive Manufacturing","Laser powder bed fusion (L-PBF)","Ti-6AL-4V ELI","Titanium Alloys","Fatigue Behavior","Mechanical Properties","Manufacturing","Other Materials Science and Engineering"],"dc:subject.lcsh":["Titanium alloys -- Mechanical properties -- Testing; Additive manufacturing -- Testing; Titanium alloys -- Fatigue -- Testing; Biomedical materials -- Technological innovations; Titanium alloys -- Industrial applications"],"dc:title":["Mechanical behavior of additively manufactured TI-6AL-4V ELI parts: Effects of laser parameter selection"],"dc:type":["Master's Thesis"],"thesis:degree_discipline":["Engineering"],"thesis:degree_name":["Master of Science in Material Science & Engineering (MS)"],"thesis:institution_name":["University of North Florida. School of Engineering"]},"updated_at":"2026-11-18T20:04:27Z"}