{"id":{"repo_id":"unf","oai_identifier":"oai:digitalcommons.unf.edu:etd-2566"},"canonical_url":"https://search.ndltd.org/etd/unf/oai:digitalcommons.unf.edu:etd-2566","repository":{"repo_id":"unf","name":"University of North Florida","base_url":"https://digitalcommons.unf.edu/do/oai/"},"display":{"title":"Development and testing of a low-cost inertial impact sensor","abstract":"Acceleration sensors have seen increasing usage within sports to detect when somebody receives an impact to their head which can potentially lead to Traumatic Brain Injury (TBI). While adoption of these sensors has steadily risen, the cost of these sensors is often cited as a reason they have not been as widely adopted, especially for amateur teams. This leads to the need for a lower-cost option for detecting these impacts. To fill this gap, a low-cost, lightweight acceleration sensor was designed that exploits the inertia of a working fluid on impact in order to rupture a metallic membrane which acts as the indicator for when a sufficient impact is received, which will require further checkup from a professional to determine whether a TBI did occur. To create a working prototype, different design properties of the sensor were tested, namely the length of the sensor, which determines the volume of the fluid within the sensor along with the type of working fluid used. By testing these different properties, the size of the device can be reduced, allowing the design to be non-intrusive for the wearer, while also reducing the device's cost. To examine the relations between the properties being tested, drop tests were performed on the sensors to determine when a rupture occurs. In the drop test, the prototype sensors were each made using acrylic tube which were cut to lengths of 20, 30, 40 and 50 mm each with the same inner diameter of 9.53 mm. Each sensor will have a thin aluminum foil adhered to one of the ends which acts as the rupturable membrane. In the drop test, the sensors were either filled with water or 70% Isopropyl Alcohol to test the viability of working fluids with different densities and surface tensions. From these tests, a range in which the membrane ruptured from an impact was found for each of the sensor lengths and working fluids used. To confirm the designs' validity and have a way to determine when the membrane should rupture, quantitative analyses were performed and compared to the drop testing results. Based on the testing performed, the relationships between impact acceleration required to rupture the membrane and sensor features will enable a working sensor for various impact thresholds to be designed by changing the working fluid or its volume.","abstract_html":"Acceleration sensors have seen increasing usage within sports to detect when somebody receives an impact to their head which can potentially lead to Traumatic Brain Injury (TBI). While adoption of these sensors has steadily risen, the cost of these sensors is often cited as a reason they have not been as widely adopted, especially for amateur teams. This leads to the need for a lower-cost option for detecting these impacts. To fill this gap, a low-cost, lightweight acceleration sensor was designed that exploits the inertia of a working fluid on impact in order to rupture a metallic membrane which acts as the indicator for when a sufficient impact is received, which will require further checkup from a professional to determine whether a TBI did occur. To create a working prototype, different design properties of the sensor were tested, namely the length of the sensor, which determines the volume of the fluid within the sensor along with the type of working fluid used. By testing these different properties, the size of the device can be reduced, allowing the design to be non-intrusive for the wearer, while also reducing the device&#x27;s cost. To examine the relations between the properties being tested, drop tests were performed on the sensors to determine when a rupture occurs. In the drop test, the prototype sensors were each made using acrylic tube which were cut to lengths of 20, 30, 40 and 50 mm each with the same inner diameter of 9.53 mm. Each sensor will have a thin aluminum foil adhered to one of the ends which acts as the rupturable membrane. In the drop test, the sensors were either filled with water or 70% Isopropyl Alcohol to test the viability of working fluids with different densities and surface tensions. From these tests, a range in which the membrane ruptured from an impact was found for each of the sensor lengths and working fluids used. To confirm the designs&#x27; validity and have a way to determine when the membrane should rupture, quantitative analyses were performed and compared to the drop testing results. Based on the testing performed, the relationships between impact acceleration required to rupture the membrane and sensor features will enable a working sensor for various impact thresholds to be designed by changing the working fluid or its volume.","abstract_has_math":false,"creators":["Pesek, Gabriel Michael","Pesek, Gabriel Michael, 2001-"],"institution":"University of North Florida. School of Engineering","degree_name":"Master of Science in Mechanical Engineering (MSME)","degree_level":null,"degree_discipline":"Engineering","degree_department":null,"school":null,"contributors":["Dr. Christopher Oshman","Dr. Grant Bevill","Dr. Lindsay Toth"],"advisors":["Oshman, Christopher","Bevill, Grant","Toth, Lindsay"],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"Summer","date_published":"Summer","updated_at":"2026-11-18T20:04:31Z","subjects":["Thesis","University of North Florida","UNF","Dissertations, Academic -- UNF -- Master of Science in Mechanical Engineering","Dissertations, Academic -- UNF -- Engineering","Acceleration Sensor","Impact Sensor","Traumatic Brain Injury","Mechanical Engineering","Crash sensors -- Testing; Detectors -- Impact testing; Concussion -- Prevention; Head -- Wounds and injuries -- Prevention"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.unf.edu/etd/1464","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.unf.edu/etd/1464","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://digitalcommons.unf.edu/context/etd/article/2566/viewcontent/ETD2030PA.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.unf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.unf.edu%3Aetd-2566","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Christopher Oshman","Dr. Grant Bevill","Dr. Lindsay Toth"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Oshman, Christopher","Bevill, Grant","Toth, Lindsay"]},{"key":"dc:creator","label":"Author","values":["Pesek, Gabriel Michael","Pesek, Gabriel Michael, 2001-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-08-17T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-01-01T08:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["Summer"]},{"key":"dc:type","label":"Dc Type","values":["Master's Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering (MSME)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of North Florida. School of Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Thesis","University of North Florida","UNF","Dissertations, Academic -- UNF -- Master of Science in Mechanical Engineering","Dissertations, Academic -- UNF -- Engineering","Acceleration Sensor","Impact Sensor","Traumatic Brain Injury","Mechanical Engineering"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Crash sensors -- Testing; Detectors -- Impact testing; Concussion -- Prevention; Head -- Wounds and injuries -- Prevention"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.unf.edu/etd/1464","https://digitalcommons.unf.edu/context/etd/article/2566/viewcontent/ETD2030PA.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Acceleration sensors have seen increasing usage within sports to detect when somebody receives an impact to their head which can potentially lead to Traumatic Brain Injury (TBI). While adoption of these sensors has steadily risen, the cost of these sensors is often cited as a reason they have not been as widely adopted, especially for amateur teams. This leads to the need for a lower-cost option for detecting these impacts. To fill this gap, a low-cost, lightweight acceleration sensor was designed that exploits the inertia of a working fluid on impact in order to rupture a metallic membrane which acts as the indicator for when a sufficient impact is received, which will require further checkup from a professional to determine whether a TBI did occur. To create a working prototype, different design properties of the sensor were tested, namely the length of the sensor, which determines the volume of the fluid within the sensor along with the type of working fluid used. By testing these different properties, the size of the device can be reduced, allowing the design to be non-intrusive for the wearer, while also reducing the device's cost. To examine the relations between the properties being tested, drop tests were performed on the sensors to determine when a rupture occurs. In the drop test, the prototype sensors were each made using acrylic tube which were cut to lengths of 20, 30, 40 and 50 mm each with the same inner diameter of 9.53 mm. Each sensor will have a thin aluminum foil adhered to one of the ends which acts as the rupturable membrane. In the drop test, the sensors were either filled with water or 70% Isopropyl Alcohol to test the viability of working fluids with different densities and surface tensions. From these tests, a range in which the membrane ruptured from an impact was found for each of the sensor lengths and working fluids used. To confirm the designs' validity and have a way to determine when the membrane should rupture, quantitative analyses were performed and compared to the drop testing results. Based on the testing performed, the relationships between impact acceleration required to rupture the membrane and sensor features will enable a working sensor for various impact thresholds to be designed by changing the working fluid or its volume."]},{"key":"dc:description.note","label":"Dc Description Note","values":["ProQuest: Yes"]},{"key":"dc:title","label":"Title","values":["Development and testing of a low-cost inertial impact sensor"]}]}],"canonical_facts":{"dc:contributor":["Dr. Christopher Oshman","Dr. Grant Bevill","Dr. Lindsay Toth"],"dc:contributor.advisor":["Oshman, Christopher","Bevill, Grant","Toth, Lindsay"],"dc:creator":["Pesek, Gabriel Michael","Pesek, Gabriel Michael, 2001-"],"dc:date.available":["2026-08-17T07:00:00Z"],"dc:date.created":["2026-01-01T08:00:00Z"],"dc:date.issued":["Summer"],"dc:description.abstract":["Acceleration sensors have seen increasing usage within sports to detect when somebody receives an impact to their head which can potentially lead to Traumatic Brain Injury (TBI). While adoption of these sensors has steadily risen, the cost of these sensors is often cited as a reason they have not been as widely adopted, especially for amateur teams. This leads to the need for a lower-cost option for detecting these impacts. To fill this gap, a low-cost, lightweight acceleration sensor was designed that exploits the inertia of a working fluid on impact in order to rupture a metallic membrane which acts as the indicator for when a sufficient impact is received, which will require further checkup from a professional to determine whether a TBI did occur. To create a working prototype, different design properties of the sensor were tested, namely the length of the sensor, which determines the volume of the fluid within the sensor along with the type of working fluid used. By testing these different properties, the size of the device can be reduced, allowing the design to be non-intrusive for the wearer, while also reducing the device's cost. To examine the relations between the properties being tested, drop tests were performed on the sensors to determine when a rupture occurs. In the drop test, the prototype sensors were each made using acrylic tube which were cut to lengths of 20, 30, 40 and 50 mm each with the same inner diameter of 9.53 mm. Each sensor will have a thin aluminum foil adhered to one of the ends which acts as the rupturable membrane. In the drop test, the sensors were either filled with water or 70% Isopropyl Alcohol to test the viability of working fluids with different densities and surface tensions. From these tests, a range in which the membrane ruptured from an impact was found for each of the sensor lengths and working fluids used. To confirm the designs' validity and have a way to determine when the membrane should rupture, quantitative analyses were performed and compared to the drop testing results. Based on the testing performed, the relationships between impact acceleration required to rupture the membrane and sensor features will enable a working sensor for various impact thresholds to be designed by changing the working fluid or its volume."],"dc:description.note":["ProQuest: Yes"],"dc:identifier":["https://digitalcommons.unf.edu/etd/1464","https://digitalcommons.unf.edu/context/etd/article/2566/viewcontent/ETD2030PA.pdf"],"dc:subject":["Thesis","University of North Florida","UNF","Dissertations, Academic -- UNF -- Master of Science in Mechanical Engineering","Dissertations, Academic -- UNF -- Engineering","Acceleration Sensor","Impact Sensor","Traumatic Brain Injury","Mechanical Engineering"],"dc:subject.lcsh":["Crash sensors -- Testing; Detectors -- Impact testing; Concussion -- Prevention; Head -- Wounds and injuries -- Prevention"],"dc:title":["Development and testing of a low-cost inertial impact sensor"],"dc:type":["Master's Thesis"],"thesis:degree_discipline":["Engineering"],"thesis:degree_name":["Master of Science in Mechanical Engineering (MSME)"],"thesis:institution_name":["University of North Florida. School of Engineering"]},"updated_at":"2026-11-18T20:04:31Z"}